X-XX UL INST ALLA TION INSTRUCTIONS Copyright © 1995 Honeywell Inc. • • All Rights Reserved T874G,R Multistage Heat Pump Thermostats and Q674F ,J,L Subbases APPLICA TION The T874G,R Thermostats with Q674F,J,L Subbases provide 24 to 30 Vac control of a two-stage heating/one- stage cooling heat pump system.
69-0268—1 1 2 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES CA UTION 1. Disconnect power supply to prevent electrical shock or equipment damage. 2. Run wires as close as possible to the subbase. To prevent interference with the thermostat linkage, keep wire length to a minimum.
69-0268—1 1 3 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES H1 FALL RISE CO L1 (HOT) L2 1 3 C1 RISE 1 2 2 3 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. TERMINAL LABELED C/X ON SOME MODELS. W3 TERMINAL ON SOME MODELS ONLY.
69-0268—1 1 4 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES H1 FALL H2 FALL CO RISE C1 RISE L1 (HOT) L2 1 2 1 2 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE JUMPER FOR INDEPENDENT CONTROL OF W1 AND E TERMINALS.
69-0268—1 1 5 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES H2 FALL H1 FALL C1 L1 (HOT) L2 1 2 2 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FACTORY-INSTALLED JUMPER. THERMOSTAT SUBBASE SYSTEM COMPONENTS H1/C1 ANTICIPATOR H2 ANTICIPATOR SYSTEM SWITCH FAN SWITCH AUTO ON OFF HEAT EM.
69-0268—1 1 6 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES H2 FALL H1 FALL C1 L1 (HOT) L2 1 1 2 2 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE JUMPER FOR INDEPENDENT CONTROL OF W1 AND E TERMINALS.
69-0268—1 1 7 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES H1 FALL C L1 (HOT) L2 1 EM. HT. LED (RED) AUX. HT. LED (GRN) W3 O L G R W2 E X X2 B W1 Y AUX.
69-0268—1 1 8 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES M5072A (HOT) L1 L2 1 LACO CHP Y B E O G L X W2 W3 R ODT 1 RTD 1 EHR 1 RTD 2 ODT 2 EHR 2 RTD 3 RD SYSTEM MONITOR FAN RELAY COMPRESSOR CONTACTOR COOL CHANGEOVER VALVE EM. HT.
69-0268—1 1 9 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES Fig. 10. Internal schematic and typical wiring diagram for T874R/Q674L in heat pump system. Includes EM. HT. and AUX. HT. LEDs. L1 (HOT) L2 1 X L W2 EM. HT. LED (RED) AUX.
69-0268—1 1 10 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES M1627A R W E X L1 (HOT) L2 COOL EM. HT. HEAT SYSTEM SWITCH AUTO ON FAN SWITCH 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE JUMPER FOR INDEPENDENT CONTROL OF W AND E TERMINALS.
69-0268—1 1 11 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES THERMOSTAT MOUNTING POST (2) M3266 50 60 70 80 HEAT THERMOSTAT MOUNTING SLOTS (2) SUBBASE THERMOSTAT CAPTIVE MOUNTING SCREWS (2) Fig.
69-0268—1 1 12 T874G,R MULTISTAGE HEAT PUMP THERMOSTATS AND Q674F,J,L SUBBASES Home and Building Control Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 69-0268—1 1 J.S. Rev . 12-95 If the setpoint lever setting and the thermometer reading do not agree, follow the procedure below.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell T874G (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell T874G noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell T874G - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell T874G reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell T874G erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell T874G besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell T874G verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell T874G. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell T874G gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.