Benutzeranleitung / Produktwartung Switches des Produzenten Honeywell
Zur Seite of 12
Sensing and Control.
2 SWITCH APPLICA TIONS CONTENTS • Ultra Duty P ressure Switches 10-400 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.3 • Extended Duty P ressure Switches 0.5-150 psi . . . . . . . . . . . . . . . . . . . . . . . . . . .
5000 Series Ultra Duty 2 T erminals Metri-Pack Integral Connector Pressure Switches (See Note 1) Contact Factory Circuitry Screw Blade Contact Factory Circuitry Part # Setting Set At Part # Part # Setting Set At N.O . 83298 83313 N .O. 83328 10-35 PSI 20 PSI N .
1.47” REF . The 5000 Series switch is specifically designed to stand up to extended duty applications. This switch is factory set but capable of field adjustment. It features a Kapton diaphragm for compatibility with a wide variety of fluids, and various terminations including a Metri-P ack connector that forms a tight seal when connected.
5 Single Circuit 1 T erminal 3. The tolerances given in the table are applicable to a switch adjusted so that the N .O . circuit closes before the N .C. circuit opens and applies to the N .C. circuit. The N .O . set point and tolerances are such that a minimum overlap of 1 PSI exists during which both circuits are on.
6 Set Points fr om 1.1” to 22” Hg 5000 Series Extended Duty V acuum Switches W ith Direct Action Blade Contacts 5000 Series V acuum Switch Circuitry Contact Setting P art Number Internally Grounded T wo T erminals P art Number 1.1-22” Hg N.O . N .
7 The 5000 Series piston switch is specifically designed for extended duty applications with set point requirements from 200 to 1000 PSI. This switch is factory set with various terminations available including a Metri-P ack connector that forms a tight seal when connected.
8 Set Points fr om 2 to 70 psi and 2” to 22” Hg Series III Factory Set V ariable Dif fer ential Pr essure & V acuum Switches With Snap Action Contacts The Series III switch is a customizable switch built per customer specifications. It features a non-ferrous chamber and excellent set point integrity at extreme temperatures.
9 Set Points fr om 35 to 3000 psi Series V High Pr essure Environmentally Sealed, Extreme-Duty Switches With Snap Action Contacts 1.187” REF . 1.187” REF .
Pressure/V acuum Switch - A device that senses a change in pressure/ vacuum and opens or closes an electrical circuit when the set point is reached. Set P oint - The pre- determined pressure/vacuum value that is required to open or close the electrical contacts in the switch.
It is the goal of Honeywell to meet customer value -needs through continuously improved products and processes. That is the basis by which we work to create a partnership with our customers. Evidence of our commitment is proven by a goal of a Shipped P roduct Quality Level (SPQL) of 100 ppm.
Sensing and Control Honeywell P .O. Box 19424 Springfield, IL 62794-9424 USA email: www .honeywellhobbs.marketing@honeywell.com www .honeywell.com/hobbs Catalog 10-1003, GLO Printed in the U.S.A. © 2004 H oneywell International Inc. All Rights R eserved.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell Switches (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell Switches noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell Switches - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell Switches reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell Switches erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell Switches besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell Switches verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell Switches. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell Switches gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.