Benutzeranleitung / Produktwartung HR90 des Produzenten Honeywell
Zur Seite of 16
1 2. Brief description 214430 The HR90 radiator controller is certified by eu.bac. With the electronic radiator controller , you can set your room temperature exactly to your requirements while additionally saving energy . Please note: The HR90 radiator controller does not directly switch your boiler on/off.
2 3. Device overview Operating elements and display 8 5 7 3 2 1 4 11 10 9 6 PROG AU TO MANU OK ECO 1 Heating period/setback period in hours 2 Day of the week 1 ... 7 (Monday ... Sunday). Displayed only while the time program is being programmed 3 T empera ture display: e.
3 1 . Pull off the adjustment dial. T o do so, start at the notch on the bottom of the device. 2 . If used, unscrew any fastening screws from the batter y compartment. 3 . Release the lock and fold out ba ttery spring. The batter y compartment is now accessible.
4 Selecting the adapter The radiator controller fits on common radiator valves of the type M30 x 1.5. Adapters are required for some valve types. 1 . Check whether an ada pter is required and, if necessary , select the appropriate adapter . Brand Illustration Adapter Honeywell- Braukmann, MNG, Heimeier , Oventrop valves M30 x 1.
5 Securing the radiator controller i The radiator controller and the batteries can be secured against removal by using the supplied screws. Setting the position of the display In order to improve the legibility the display of the radiator controller can be tilted to different positions (10°, 20°, 30°, 40°).
6 Cable connection i For further information also refer to the documentation for HCW23, RF20 and HCA30. f Connect the ACS90 cable as follows to the external sensor and window contact: HCW23 setpoint a.
7 Saving energy in ECO mode In ECO mode, the room tempera ture in automatic mode specified by the time program is lowered by 3 °C. f T o activate ECO mode, press the button A UT O/ ECO/MANU until economy is displayed. The displayed temperature is reduced by 3 °C .
8 7. Programming – T emperatures Three preset temperatures can be assigned to the set points in the time program: • Comfort temperature 1 Factory setting 20 °C • Comfort temperature 2 Factory setting 22 °C • Setback temperature Factory setting 16 °C Setting the temperatures 1 .
9 The example shows the following time program: Set- point Time T emperature 1 6:00 – 9:00 20 °C (Comfort temperature 1) 2 9:00 – 12:00 16 °C (Setback tempera ture) 3 12:00 – 14:00 20 °C (Com.
10 Deleting a setpoint f When a setpoint is not required, select the temperature setting --.- and confirm with OK . i The first setpoint cannot be deleted. Adding a setpoint 1 . T urn the adjustment dial until add new is displayed and confirm with OK .
11 9. Controller operating parameters Overview If required, the 19 basic settings (parameters) can be adjusted. Factory settings have a grey background.
12 Changing parameters 1 . Keep the PROG button pressed for at least 10 seconds until Parameter 1 flashes (left-hand digit). The right-hand digit shows the current setting. The parameter is displayed additionally in plain text. For example, the display 1 1 stands for Parameter 1 (language) with Setting 1 (German).
13 Parameters 5 to 7 – Window function In order to save energy , the radia tor controller closes the radiator valve when you open a window resulting in a large drop of the temperature. When you close the window so that the temperature rises the radiator controller opens the radiator valve again.
14 10. Further functions Monitoring functions Window function If you open a window causing the temperature to drop, the radiator controller closes the radiator valve in order to save energy .
15 11. Help with problems Error table Problem/ Display Cause Remedy flashes Batteries flat Replace the batteries. e1 sensor Device defective Replace the device. e2 valve Motor can not be moved. Check the installation. The radiator stays hot The radiator valve does not close fully .
Honeywell Honeywell House Skimped Hill Lane Bracknell Berkshire RG12 1EB United Kingdom The right is reserved to make modifications that serve improvement. 50080331-001C www .hr90.info Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell T echnologies Sàrl, ACS-ECC EMEA, Z.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell HR90 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell HR90 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell HR90 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell HR90 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell HR90 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell HR90 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell HR90 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell HR90. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell HR90 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.