Manning GM -1 Gas Mo nitoring A larm Syste m 19546 GM1 07/09 REVD Copyright © 2009 Honeywell Analytics. All Rights Reserved. 1 07/09 Release D Draft Honeywell Confidential & Proprietary This work contains valuable, confide ntial, and proprietary information.
Notices and Trademarks Copyright 2009 by Honeyw ell International In c. Release D July 2009 While this infor mation is presented in go od faith and believed to b e accurate, Ho neywell disclaims the i.
About This Document World Wide Web The following Hon eywell web sites may b e of interest. Honeywell Organization WWW Address (URL) Corporate www.honeywe ll.com Honeywel l Analyt ics www.honeywe llanalytic s.com Manning Gas Detect ion www.manning systems.
Contents Serial number: Secti on Title Page 1 System Description 5 2 Installation 7 3 Operation 10 4 Limited Warranty 13 Introduction This manual has b een prepared to h elp in the use and installatio n of the Manning GM- 1 Gas Monitoring Alarm System.
1 System Description The Manning GM-1 is designed to accept a sing le 4/20 mA curre nt input signal, plu s provide a regula ted 24 VDC supply to operat e all sensors manu factured by Honeywel l Analyt ics. The Manning GM-1 is housed in a r ugged 14 gauge gasketed steel enc losure.
1 System Description continue d System Specific ations Electrical Power: 120 VAC, 50/60 Hz at 0.35 amp (230 VAC 50/60 Hz is available as an option) Signal input: 4/20 mA DC Power available for sensors.
2 Installation A Locating the Manning GM-1 Figure 1: Mounting dimensions for the Manning GM-1 Gas Monitoring Alarm System When unpacking the unit, ins pect all boxes and contents for sh ipping damage.
2 Installation continued B Wiring Relay Wiring: All three relays have Form C, dry contacts. An y required power source must be within the 3 amp rating and fused or current limited to keep from damaging the contacts. Electrical wiring must co mply with all applicable codes.
2 Installation continued Figure 2: Wiring diagram for the Mann ing GM-1 Gas Monitoring Alarm System NO NC C NO NC C NO NC C LN WARNING RELA Y* 120 V AC WARNING RELA Y WARNING ADJUST ALARM ADJUST TP WA.
3 Operation A Display Panel C DIP Switch Setting A 20-segment Bargr aph Display indicates the gas concentration leve l. The bottom LED is always lit to indicate power to the display. The two position DIP switch in the center of the bottom board control s the latching of t he alarm ligh t and alarm relay.
3 Operation continued D Signal and Setpoints The voltage between TP Gnd and TP Sig indicates the current sig nal received from t he sensor. Th e normal range is 0 .4 volts to 2.0 volts, which corresponds with 4/20 mA. This m anual will use the voltage at TP Sig t o describe the input signal.
3 Operation continued G Maintenance The Manning GM-1 is designed for lon g life and high reliability. Honeywell Analytics recomm ends checking signal vo ltages monthly and log ging them on the data sheet included with your M anning GM-1.
4 Limited Warranty 1. Limited Warranty Honeywell Analy tics, Inc. warrant s to the original purchaser and/or ultimat e customer (“Purchaser”) of M anning produc ts (“Product”) that if any part.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell GM-1 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell GM-1 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell GM-1 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell GM-1 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell GM-1 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell GM-1 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell GM-1 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell GM-1. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell GM-1 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.