PRODUCT DA T A F1 16 (Series 16000) Self-Cont ained Duct able Commercial Air Cleaner APPLICA TION The F1 16 (Series 16) Self-Contained Duct able Commercial Air Cleaner uses direct drive forward curve blower/motor with a variety of filter configurations to remove airborne contaminant s.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 68-0200-2 Revised 10-07 2 ORDERING INFORMA TION If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 3 68-0200-2 T able 2. F1 16 (Series 16000) Maximum St arting Loads. Air V olume, Internal St atic Pressure and Installation Weight: Air volume, internal static pressure and installation weight are based on the air cleaner filter configuration.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 68-0200-2 Revised 10-07 4 T able 4. F1 16 (Series 16000) Filter Description. r e t l i F n i s n o i s n e m i D ) m m ( s e h c n.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 5 68-0200-2 26 (660) 26 (660) 48 (1219) 24-1/4 (616) 22-1/4 (565) 16 TYP (406) 5 TYP (127) 3/8 THREADED INSERT HOLE FOR HANGING INSTALLATION HEPA, D.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 68-0200-2 Revised 10-07 6 Fig. 2. Approximate dimensions of three stage filtering model in in. (mm). Please Note : Electrostatic Precipitator Collecting Cells are no longer available.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 7 68-0200-2 S t atic Pressure The F1 16 (series 16000) uses a forward curve blower/ motor . The electrical current draw is determined by combining the air volume to be moved with the filter and ducting static pressure.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 68-0200-2 Revised 10-07 8 Smoking Section Non- Smoking M7783 Fig. 4. Positioning air cleaners at the far end of the restaurant smoking section to draw the smoke away from the nonsmoking section.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 9 68-0200-2 M10795 AIR CLEANER Fig. 6. Positioning air cleaner for printing shop, brazing, soldering or gluing vapor control. 30 FT (9M) 30 FT (9M) 30 FT (9M) CURTAIN AIRFLOW AIR CLEANER WORK AREA M10796 AIR CLEANER Fig.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 68-0200-2 Revised 10-07 10 FLEXIBLE STATIONARY M10799 AIR CLEANER AIR CLEANER Fig. 10. Positioning air cleaner for suspended side draft applications. DO NOT INSTALL WHERE THERE IS HEAVY OIL SMOKE, COOKING, HEAVY WELDING OR HEAVY CUTTING.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 11 68-0200-2 THREADED ROD HEX BOLT LOCK WASHER TOP OF AIR CLEANER CABINET JAM NUT JAM NUT 3/8 x 16T EYEBOLT CHAIN 3/8 x 16T NUTS INSTALLED IN CABINET CORNERS FASTEN SECURELY TO STRUCTURAL SUPPORT SYSTEM I.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 68-0200-2 Revised 10-07 12 SERVICE IMPORT ANT Air cleaners and components are susceptible to damage. T ake care when working with them to avoid equipment damage. The air cleaner removes a variety of particulate cont aminants from the air .
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 13 68-0200-2 TROUBLESHOOTING W ARNING Electrical Shock Hazard Can cause personal injury or equipment damage. The following procedures expose hazardous live parts. Disconnect power supply between checks and proceed carefully .
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 68-0200-2 Revised 10-07 14 PARTS LIST Refer to T able 6 and Fig. 18 for the part s list and exploded view . T able 6. F1 16 (Series 16000) Self-Contained Duct able Commercial Air Cleaner Parts List.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 15 68-0200-2 (ELECTROSTATIC PRECIPITATOR COLLECTING CELL) 1 (PREFILTER) 2 (SORBENT MODULES) M10812 (HEPA, D.O.P. OR ASHRAE FILTERS) 1 1 TWO STAGE MODELS WILL HAVE ONLY ONE PRIMARY FILTER AREA.
F1 16 (SERIES 16000) SELF-CONT AINED DUCT ABLE COMMERCIAL AIR CLEANER 68-0200-2 Revised 10-07 16 LIMITED TWO-YEAR W ARRANTY Air-Pure Systems 16873 Fish Point Rd.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell F116 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell F116 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell F116 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell F116 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell F116 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell F116 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell F116 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell F116. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell F116 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.