Hone ywell EC-P2 Instruction Manual CHAR GE B A TT ER Y WHEN N OT I N US E Gas Detector EC-P2.
.
Honeyw ell EC-P2 Instruction and Installation Manual 3 Cop yright 2009 by Honeyw ell International Inc. Release J July 2008 While this inf or mation is presented in good f aith and belie ved to be acc.
Honeyw ell EC-P2 Instruction and Installation Manual 4 Introduction This manual has been prepared to help in the use of the Honeywell EC-P2 P ortable Gas Detector . This manual must be carefully followed by all individuals who have or will have the responsibility f or using or servicing this device.
Honeyw ell EC-P2 Instruction and Installation Manual 5 Introduction .................................................................................... 4 1 System Description ...........................................................................
Honeyw ell EC-P2 Instruction and Installation Manual 6 Data Logging with the Honeyw ell EC-P2: ............................... 18 W orking with the “EC-P2” program: ......................................... 19 4.5 Analog Output ...................
Honeyw ell EC-P2 Instruction and Installation Manual 7 1 System Description The Honeywell EC-P2 is a por table , batter y operated instrument for the measurement of gas concentrations in ambient air .
Honeyw ell EC-P2 Instruction and Installation Manual 8 System Specifications Primary Po wer: Alkaline D cell battery , 75 hours operation. Note: An audible alarm singl e beep ev er y 60 seconds indic ates th at eithe r the Alk aline D cell battery is lo w or the internal rechargeable NiCad batter y is low .
Honeyw ell EC-P2 Instruction and Installation Manual 9 The normal operating screen displays the inf ormation as shown in Figure 2 . The Honeyw ell EC-P2 is designed to avoid accidental shut-off of the power . T o turn the unit off, the PWR button must be held down for appro ximately three seconds.
Honeyw ell EC-P2 Instruction and Installation Manual 10 ME NU SM P L P PM N H 3 O FF 0 P A Power BA TTER Y I N USE P = Pr imar y (“D” cell ) S = S ta ndb y (In ter n al N iCad ) Flashi ng in dica .
Honeyw ell EC-P2 Instruction and Installation Manual 11 2.6 Interference Gases The Honeywell EC-P2 is generally quite specific to the target gas, but depending on the target gas, other gases ma y cause a reading. See Appendix B for a listing of potential interf erence gases for the v ar ious SMART -CELLs.
Honeyw ell EC-P2 Instruction and Installation Manual 12 3 Maintenance 3.1 P eriodic Maintenance It is esse ntial that the t est a nd ca librati on sc hedul e be adher ed to. Ho neywell Analytics recommends the f ollowing maintenance schedule: Response test prior to each use.
Honeyw ell EC-P2 Instruction and Installation Manual 13 Note: The unit may be zeroed without spanning it; however , never span the unit without rst zeroing it. The f ollowing procedure will calibrate the SMAR T -CELL. T o Enter ZER O / SP AN Mode Push power button to tur n unit on.
Honeyw ell EC-P2 Instruction and Installation Manual 14 External flowmeter indicates no flow: V er ify that pump is running. Check that the manif old screws are tight and the e xtension w and connection is tight. Unit does not respond when keys are pressed: Press and hold all four buttons f or fiv e seconds.
Honeyw ell EC-P2 Instruction and Installation Manual 15 4 Programming and Ad v anced Features 4.1 Alarm Setpoints, Functions The Honeyw ell EC-P2 has three adjustable alarm setpoints. These setpoints are stored on each SMART -CELL. The Caution setpoint is to w arn of excessiv e negative zero drift.
Honeyw ell EC-P2 Instruction and Installation Manual 16 W arning Function Push W ARN button. 4. Push FUNC (function) button. 5. Push SELECT button while viewing the arrow in the lower left hand cor ner 6.
Honeyw ell EC-P2 Instruction and Installation Manual 17 A V G V ariable Push A V G button. 5. Push INC button (increase) or DEC b utton (decrease) until the display 6. matches the desired value . Push SA VE button to store ne w A V G v ariable. 7. T o Exit A V G / BLANK Mode Push DONE button twice slo wly to get back into normal operation mode.
Honeyw ell EC-P2 Instruction and Installation Manual 18 Push the MORE button. 3. Push the SMPL (sample) button and the unit is no w in the SAMP / MEAS 4. / CLEAR mode. SAMP V ariable Push SAMP (sample) button. 5. Push INC button (increase) or DEC b utton (decrease) until the display 6.
Honeyw ell EC-P2 Instruction and Installation Manual 19 Push INT button (inter val) to cycle through the choices for how often to 5. log a data point. Stop when the desired interval is displayed. Notice how much time can be cov ered with the remaining free memor y .
Honeyw ell EC-P2 Instruction and Installation Manual 20 Each SMAR TCELL has a wide range of choices of full scale v alues. Note: The full scale range as programmed below only affects the analog output and the data logging full-scale output. The displa y will alwa ys cov er the entire operating range of the SMART -CELL.
Honeyw ell EC-P2 Instruction and Installation Manual 21 Appendix A A vailable SMAR T -CELLs Gas Min Range Max Range Resolution P art Number Alcohol 0-50 ppm 0-500 ppm 1 ppm 10167 Ammonia (NH 3 ) 0-50 ppm 0-500 ppm 1 ppm 10168 Ammonia (NH 3 ) 0-500 ppm 0-2000 ppm 1 ppm 10169 Bromine (Br 2 ) 0-1 ppm 0-5 ppm 0.
Honeyw ell EC-P2 Instruction and Installation Manual 22 BR 2 Cl 2 ClO 2 O 3 NH 3 CO H 2 O 2 NO H 2 S NO 2 SO 2 HCHO OH Fl 2 HCl H 2 O 2 Bromine ----- 1.0 1.0 0.7 -0.1 None None None None None 0.5 -0.1 None None 1.0 None None Chlorine 1.0 ----- 1.0 0.7 -0.
Honeyw ell EC-P2 Instruction and Installation Manual 23 Notes: None means there is no interf erence. 1. A number indicates that when exposed to the interf erence gas, the sensor 2.
Honeyw ell EC-P2 Instruction and Installation Manual 24 Limited W arranty 1. Ho ne yw el l An aly tic s Inc.. (“HA” ) w arr ants to the original purchaser and/or ultimate cust ome r (“P urc hase.
Honeyw ell EC-P2 Instruction and Installation Manual 25.
.
.
11385 Rev J July 2009 © 2009 Honeywell Analytics Find out more www .honeywellanalytics.com Contact Honeywell Analytics: Americas Honeywell Analytics 405 Barclay Boule vard Lincolnshire, IL 60069 USA T el: +1 847 955 8200 T oll free: +1 800 538 0363 F ax: +1 847 955 8208 detectgas@honeywell.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell EC-P2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell EC-P2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell EC-P2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell EC-P2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell EC-P2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell EC-P2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell EC-P2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell EC-P2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell EC-P2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.