1 CT70 Heat Pump Thermostat W iring Guide.
2.
3 HOW TO USE THIS GUIDE Before you disco nnect the wires and remove your existing thermost at, be sure this new th ermostat, se e the CT70 wiring hookup dia gram, will replace it and that you understand h ow you will reconnect the wiring.
4.
5 TABLE OF CONTENTS How to Use Th is Guide ................ ........... .......... ........ .... 3 Heat Pum ps are Different ........... .......... ........ .......... ....... 6 Heat Pum ps are T wo Systems in One ........... ........ ....... 7 Definitions o f T ermin al Functions .
6 HEAT PUMPS ARE DIFFERENT Heat pum p system s usually have a supplemental, Second S tage heating system that operates only when necessar y . This heat pump thermostat is designed to minimize more expensive second- stage oper ation, indicated by the green AUX.
7 HEAT PUMPS ARE TWO SYSTEMS IN ONE In mild weather , virtually all of the demand for heat in buildings can be met by the he at pump compressor . This First St age proc ess of mov ing heat i ndoors is very economic al.
8 DEFINITIONS OF TERMINA L FUNCTIONS Each terminal of t he CT70 controls a dif ferent heat pump function. Here is a list of the possible heat pump functions: Function Defini tion FIRST STG. HEAT: When this terminal is activated, the heat pump is on and heating the living s pace.
9 FAN: When this terminal is activated, the fan is on. With the fan switch in the auto position, the fan cycles on and off with the heat pump. With the f an switch in t he ON position, the fan is on continuously . MULTIPLE AUX. HEAT LOADS: This terminal is activated when additional auxiliary heat loads are required.
10 T ypical wiring hookup of CT70 with jumper inta ct. M8504 W2 W1 X O E G Y1 R L B L1 (HOT) L2 1 POWER SUPPL Y . PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. REMOVE W1-Y1 JUMPER WHEN HEA T RELA Y 1 IS USED. WHEN L TERMINAL IS CONNECTED T O SYSTEM MONITOR, EM.
11 AMANA ! Jumper these two terminal s if both are present # This terminal must b e connected to transforme r common. $ Remove this f actory-inst alled jump er for inde pendent sta ge 1 heat and cool connection. W1 Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER COMPRESSOR 1 ST STG.
12 BARD/JANITROL/TAPPAN/WILLIAMSON ! This terminal must b e connected to transforme r common. # Leave factory-i nstalle d jumper in place. $ Connect multiple second stage heating loads to W2 termina ls. % Thermostat is con nected to eith er O or B terminal, b ut not both.
13 ARCOAIRE/SN YDER GENERAL/COMFORT MAKER ! This terminal must b e connected to transforme r common. # Leave factory-i nstalle d jumper in place. Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER COMPRESSOR 1 ST STG.
14 B.D.P. (BRYAN T-DAY/NIGHT-PAYNE) ! This terminal must b e connected to transforme r common. # Leave factory-i nstalle d jumper in place. $ Connect multiple second stage heating loads to W2 termina ls. Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER COMPRESSOR 1 ST STG.
15 CARRIER ! This terminal must b e connected to transforme r common. # Leave factory-i nstalle d jumper in place. Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER COMPRESSOR 1 ST STG. HEAT AUX. HEAT FAN C/O VALVE HEAT C/O VALVE COOL SYSTEM MONITOR EM.
16 FRIEDRICH ! This terminal must b e connected to transforme r common. # Leave factory-i nstalle d jumper in place. $ T ape of f the end of the wire. Jumper is not required on this thermostat (CT70). Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER COMPRESSOR 1 ST STG.
17 HEIL QUAKER/WHIRLPOOL/TEMPSTAR ! This terminal must b e connected to transforme r common. # Leave factory-i nstalle d jumper in place. Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER COMPRESSOR 1 ST STG. HEAT AUX.
18 LENNOX ! This terminal must b e connected to transforme r common. # Leave factory-i nstalle d jumper in place. R Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER 1 ST STG. HEAT (COMP) 1 ST STG. COOL 2 ND STG. HEAT FAN C/O VALVE HEAT C/O VALVE COOL SYSTEM MONITOR EM.
19 RHEEM/RUUD ! This terminal must b e connected to transforme r common. # Leave factory-i nstalle d jumper in place. Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER COMPRESSOR 1 ST STG. HEAT AUX. HEAT FAN C/O VALVE HEAT C/O VALVE COOL SYSTEM MONITOR EM.
20 TRANE/AMERICAN STANDARD ! This terminal must b e connected to transforme r common. # Leave factory-i nstalle d jumper in place. $ T ape off end. CT70 replace s outdo or reset with impr oved zero droop per forman ce. Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER 1 ST STG.
21 YORK/BORG WARNER/LUXAIRE (MONCRIEF, FRASER-JOHNSTON) ! This terminal must b e connected to transforme r common. # Connect multiple second stage heating loads to W2 termina ls. $ Leave factory-i nstalle d jumper in place. % If pres ent on or iginal equipme nt.
22 YORK/BORG WARNER ! This terminal must b e connected to transforme r common. # Remove factory-installed jumper . Wiring terminal function Existing thermostat wiring New thermostat wiring COMMON POWER 1 ST STG. HEAT AUX. HEAT FAN 1 ST STG. COOL C/O VALVE HEAT C/O VALVE COOL SYSTEM MONITOR EM.
23.
69-0866— 2 C.H. Rev . 01-95 www .hone ywell.com/yo urhome Automation and Control Solu tions Honeywe ll Intern ational Inc. 1985 Douglas Dr ive North Golden Valley, MN 554 22.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell CT70 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell CT70 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell CT70 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell CT70 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell CT70 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell CT70 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell CT70 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell CT70. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell CT70 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.