Benutzeranleitung / Produktwartung Central Heating Cooker Natural Gas des Produzenten Honeywell
Zur Seite of 44
Central Heating Cooker Natural Gas Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) C603352 Issue 2 (Jan 2004) IMPORTANT The front casing of this appliance w.
2 HEALTH AND SAFETY INFORMATION FOR THE INSTALLER AND SERVICE ENGINEERS Under the Consumer Protection Act 1987 and the Health and Safety at Work Act 1974, it is a requirement t o provide information on substances hazardous to health (COSHH Regulations 1988).
3 GENERAL SAFETY INSTRUCTIONS Read and understand this booklet before operating and installing this appliance. 1 The person(s) who installs this appliance, commissions, services or carries out any remedial work, ie electrical fault finding must be Corgi registered.
4 CONTENTS Imortant Information 5 USER INSTRUCTIONS 6 Oven Cooking Guide 10 Care of the Cooker 12 Fault Finding Charts 13 After Sales Service Information 14 Technical Details 16 Site Requirements 17 I.
5 IMPORTANT INFORMATION Congratulations you are now the proud owner of the new Redfyre Central Heating Cooker which is capable of providing full central heating and domestic hot water. As manufacturers we are proud of the features, and quality of construction of all our cookers.
6 The Redfyre cooker has two large ovens. The main oven works similar to a conventional oven which is controlled by its own programmer and thermostat, this thermostat also controls the rest of the appliance.
7 USERS INSTRUCTIONS COOKER BURNER 5.1 The cooker burner is fully automatic and requires no manual intervention to light. Ensure that the programmer is in the ON mode, neon glowing, and turn the thermostat to the desired temperature. The cooker light will illuminate and once the desired temperature has been reached it will extinguish.
8 USER INSTRUCTIONS Setting event times Step A 6.7 Press PROG to advance to the next step. The display will be as in diagram 4. Step B 6.8 Press and release the+ or - buttons to change event 1 ON time in increments of one minute. Note: If buttons are held down, the time will change in increments of 10 minutes.
9 USER INSTRUCTIONS 9.1 This is a blocked flue sensing device. This is an important safety device to prevent the products of combustion entering the room due to a flue problem. Under no circumstances must this device be put out of operation whilst the cooker is in use.
10 OVEN COOKING GUIDE PLEASE NOTE - THESE TABLES SHOULD BE USED AS GUIDENCE ONLY AS EACH COOKER AND ITS INSTALLATION WILL VARY SLIGHTLY. 1.1 Meat cooked in a heat storage cooker has very little shrinkage and rarely requires any additional fat for cooking.
11 OVEN COOKING GUIDE NOTE: Pastry recipes may benefit from placing on the floor of the oven for the last 10-15 min of cooking. Shelf positions are counted from the top down 1,2,3, and 4.
12 CARE OF THE COOKER IMPORTANT: Never use caustic, citric, or abrasive cleaners as these will scratch or damage the surface. Always try to wipe up any spillages when they occur. A more satisfactory result will be achieved if the cooker is cool when cleaning.
13 USER COOKER FAULT FINDING COOKER WILL NOT START CHECK THE FUSE IN COOKER & BOILER MAINS SUPPLY HAS NOT BLOWN CHECK COOKER THERMOSTAT IS SWITCHED ON AMBER NEON WILL BE ILLUMINATED IS THE COOKER .
14 USER BOILER FAULT FINDING BOILER WILL NOT WORK SET EXTERNAL PROGRAMMER IS THE BOILER HIGH LIMIT RESET NEON ILLUMINATED ON THE CONTROL PANEL PRESS RESET BUTTON - (DO NOT RESET MORE THAN TWICE IF FAU.
15 REDFYRE CUSTOMER AFTER SALES SERVICE INFORMATION A step by step guide to reporting a fault with your appliance A qualified field SERVICE ENGINEER is available to attend a breakdown or manufacturing fault occurring w hilst the appliance is under guarantee.
16 TECHNICAL DETAILS Model Cooker 60 80 100 120 Rated input kw (gross) 17.6 22.2 29.7 37.3 45.5 Rated output kw (gross) - 17.6 23.4 29.3 35.2 Burner Cooker Boiler - 60k Boiler - 80k Boiler - 100k Boiler - 120k Gas Volume m 3/jr 1.68 2.11 2.84 3.56 4.34 Co2 % 8.
17 SITE REQUIREMENTS Sound Levels Whilst the level of sound is low it is important that the following aspects should be considered before installation: (a) The Flue pipe from the appliance should be cast iron (b) Some people are particularly sensitive to even low noise levels so this aspect should be discussed with the householder.
18 SITE REQUIREMENTS 51 87 126 167 206 70 158 604 1440 clearance, (Min.) 985 915 970 125 FLOW and RETURN tappings 1 ” BSP CENTRAL HEA TING COOKER DIMENSIONS Gas Electric 1 4.
19 INSTALLATION INSTRUCTIONS 1.1 The Redfyre range of Central Heating cookers is a range of floor mounted storage central heating cookers with a fixed rate cooker burner and the option of four fixed rate central heating outputs depending on heating load.
20 INSTALLATION 1.1 The supply pipe from the cooker is 3/4” BSP threaded male. An isolating gas valve must be fitted adjacent to the cooker and the gas installation pipe work must be installed, insp.
INSTALLATION 21 4.1 Before using any existing chimney or refitting a gas appliance, it is vital to check that the chimney is safe. Oversized, leaking or rough chimneys can be inefficient and dangerous. 4.2 There are two basic existing types of chimney re-lining product suitable for use with gas appliances.
22 FLUE SYSTEMS WIND HIGH LOW HIGH LOW HIGH L O W ROOF PITCH OVER 30 ° ROOF PITCH OVER 30 ° FLAT ROOF 5. WIND EFFECTS ON BUILDINGS 6. IMPORTANT NOTES The following drawing shows the general high and low pressure areas on buildings. Flues should not be terminated in a high pressure area.
23 FLUE TERMINATION IRRESPECTIVE OF THE TYPES OF CHIMNEY SYSTEM, A BRITISH GAS APPROVED TERMINAL MUST BE USED Recommended flue positions for some roof conditions.
24 WATER SYSTEMS 1.1 The appliance is suitable for fully pumped open vent & sealed systems only and the installation must comply with the requirements of BS 6798 and BS 5449.
25 OPEN SYSTEMS PLUMBING ‘Y’ PLAN.
26 OPEN SYSTEMS PLUMBING ‘S’ PLAN.
27 ELECTRICAL SUPPLY Electrical Supply 230V 1 Phase 50Hz (Fused 3 amp) Note: THIS APPLIANCE MUST BE EARTHED All electrical wiring must be carried out by a qualified electrician in accordance with current I.E.E. Regulations and any Local Regulations that may apply.
28 COOKER INTERNAL WIRING.
29 WIRING ‘S’ PLAN Independent control or space and water heating circulation in a fully pumped system with two motorised valves (see System Diagrams 1 and 2) This scheme provides the optimum degree of control over a fully pumped installation.
30 WIRING ‘Y’ PLAN Independent control of space and water heating circulation ina fully pumped system with one motorised diverting valve (See System Diagram 3) This scheme provides control over a fully pumped instalation by means of a single motorised diverting valve.
31 SERVICING To maintain the appliances high thermal efficiency and reliable operation, it must be serviced annually which is also a requirement of the appliances guarantee. If the boiler is used to provide central heating and hot water, we recommend that the appliances annual service is carried out just before the start of the heating season.
32 SERVICING To remove the cooker burner, the boiler burner needs to be removed first following the section on boiler burner removal a) Remove the lower panel as detailed above. b) Remove the boiler burner as detailed previously. c) Disconnect the cooker burner 6 way plug, the ignition lead, and the ionisation lead from the control box.
33 SERVICING a) Remove the upper programmer retaining panel, four screw and starlock washers at the four corners of panel. b) Supporting the panel ease forward and release 6 way plug (two lugs). Carefully put panel at one side. c) Access to the underside of the control panel will need to be gained by following the section above.
34 SERVICING f) Replace in reverse order ensure heat shield large opening is at the top of the panel. g) Reset the programmer to the current time and program to customer requirements. See Fig. 11 a) Remove the lower control panel and remove the smaller blocked flue thermostat panel 2 screws.
35 SERVICING The boiler access door is behind the programmer mounting panel. Carefully remove the programmer mounting panel secured with fixing screws and disconnect the electrical plug. Remove the boiler access door by unscrewing the 4 wing nuts - check rubber seal and renew if necessary.
36 SERVICE ENGINEER GUIDE TO FAULT FINDING NO CHECK OPERATION OF LIMIT THERMOSTAT AND NEON INDICATOR NO IS THERE 230V ON TERMINAL OF MAINS INLET PLUG IS THERE 230V ON TERMINAL L OF COOKER PROGRAMMER I.
37 SERVICE ENGINEER GUIDE TO FAULT FINDING IS THERE 230V ON TERMINAL S3 OF MAINS INLET PLUG IS THERE 230V ON TERMINAL 2 OF BOILER STAT (RED WIRE) IS THERE 230V ON TERMINAL ON BOILER LIMIT WITH RED AND PURPLE WIRE.
38 FAULT FINDING ELECTRICITY SAFETY - Switch off electrical supply to unit before making any electrical tests. FAULT POSSIBLE CAUSE ACTION BURNER WILL NOT START Boiler Thermostat or other Ensure all c.
39 SPARE PARTS: BURNER Item Part Description 1 Burner Head 603380 603381 603381 603381 603381 2 Ionisation probe + lead 603382 603382 603382 603382 603382 3 Ignition Electrode 603383 603383 603383 603.
40 SPARE PARTS LIST Item Description Part No. 1 Door Catch Chrome R/H 602884 2 Door Catch Chrome L/H 602883 3 Door Seal 602911 4 Spring 602088 5H inge pin 33097 6 Buffer 99593 7 Enamelled Door Liner 6.
41 SPARE PARTS LIST 16 15 6 5 2 28 14 25 7 4 3 1 29 30 31 32 9 10 11 12 8 13 EXPLODED VIEW.
42 21 22 19 18 20 27 23 23 26.
43 2 6 1 7 3 4 5.
Redfyre Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 444070 Fax: (01392) 444804 E-mail: redfyre@gazco.com A division of Gazco Limited.
Ein wichtiger Punkt beim Kauf des Geräts Honeywell Central Heating Cooker Natural Gas (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Honeywell Central Heating Cooker Natural Gas noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Honeywell Central Heating Cooker Natural Gas - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Honeywell Central Heating Cooker Natural Gas reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Honeywell Central Heating Cooker Natural Gas erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Honeywell Central Heating Cooker Natural Gas besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Honeywell Central Heating Cooker Natural Gas verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Honeywell Central Heating Cooker Natural Gas. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Honeywell Central Heating Cooker Natural Gas gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.