Benutzeranleitung / Produktwartung HPGF15 des Produzenten Hobart
Zur Seite of 24
701 S. RIDGE AVENUE TROY, OHIO 45374-0001 www.hobartcorp.com FORM 34709 (September 2001) N S T R U C T I O N S I MODEL HPGF15 GAS PRESSURE FR YERS ML-126825.
– 2 – © HOBART CORPORATION, 2001 IMPOR T ANT FOR Y OUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
– 3 – T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION . . . . . . . . . . . . . . . . . . . . . .
– 4 – Installation, Operation and Care of MODEL HPGF15 GAS PRESSURE FR YERS SA VE THESE INSTR UCTIONS FOR FUTURE USE GENERAL Your Hobart Gas Pressure Fryer will produce a uniform, high-quality product time after time. It operates at a low temperature (325°F [163°C]) and high pressure (14 psi).
– 5 – LOCATION The equipment area must be kept free and clear of combustible substances. The pressure fryer, when installed, must have minimum clearance from combustible and noncombustible construction of 1" (2.5 cm) at the sides and 3" (7.
– 6 – Installing Casters Place the fryer on its side, being careful to avoid scratching the surface. Use only the casters supplied with your pressure fryer. Thread the four casters to the flanges on the bottom corners of the fryer. Use the open-ended wrench supplied to tighten (apply wrench at the flat surfaces on leg extensions) (Fig.
– 7 – Exhaust Pipe Thread the 1 1 / 4 " diameter exhaust pipe (supplied) to the top of the exhaust tank (Fig. 3) located at the rear of the fryer. Fig. 3 GAS CONNECTIONS All gas supply connections and any pipe joint compound used must be resistant to the action of liquified petroleum gases.
– 8 – TESTING THE GAS SUPPLY SYSTEM When test pressures exceed 1 / 2 psig (3.45 kPa), the fryer and its individual shutoff valve must be disconnected from the gas supply piping system.
– 9 – Fig. 4 Fig. 5 PL-40936-1 EXHAUST VENT HAS BEEN REMOVED TO SHOW V AL VE CLEARL Y PL-40937-1 GAS V AL VE IN ON POSITION.
– 10 – 0 30 25 20 15 10 5 PL-52686 PRESSURE GAUGE OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK.
– 11 – FILLING THE KETTLE WITH LIQUID SHORTENING Oil Capacity: 40 lb/5 gal (18 kg/19 L). Use only a pure vegetable hydrogenated oil prescribed for use in pressure fryers, such as Mel Fry, Crystal, FryMax or Gold Label. Never add suet. Close drain valve (Fig.
– 12 – FRYING PROCEDURE FOR ALL FOODS Pressure is created by the containment of moisture escaping from the product being fried. Dry products that produce little or no moisture will not create sufficient pressure to fry that product. Pressure will not build without product in the kettle.
– 13 – 9. When pressure gauge reads 0, turn the handle counterclockwise until it stops before opening the lid. CAUTION: Seal damage can occur if handle is not completely unscrewed. Do not force the lid to open. ALWAYS swing the lid to the side. DO NOT raise the lid.
– 14 – PRESSURE-RELIEF VALVE The pressure-relief valve is located on the fryer lid. This relief valve is nonadjustable and preset at the factory to release the kettle pressure automatically if over 15 psi. This valve is also equipped with a ring (Fig.
– 15 – Other Items Which May Be Prepared in the Pressure Fryer TEMP. TIME FOOD (°F) (Min.) Chicken Fried Steak 325 8 Liver 325 4 Sweet Breads 325 4 Fish Fillets (Frozen & Prebreaded) 325 5 Sh.
– 16 – PL-40901 5. When clean, close drain valve and return oil to kettle. 6. Remove drain elbow. 7. Check oil level and turn fryer on. Cooking can resume when the white cooking light goes out. Filtering Oil at the End of the Production Day This procedure must be done while the kettle is still warm.
– 17 – Fig. 13 PL-41468-1 DIAPHRAGM Fig. 12 11. Continue with the cleaning instructions described in the CLEANING section of this manual. 12. Close drain valve and return oil to kettle. 13. Remove drain elbow. 14. Check oil level. The fryer is ready for the next production period.
– 18 – Cleaning After Every Production Period Exhaust Tank Drain the exhaust tank at the end of every production period while the liquid is hot. The exhaust tank drain valve is located behind the front access door at the lower right. 1. Attach drain pipe extension (supplied) and drain exhaust tank by turning drain valve handle up (Fig.
– 19 – Fig. 16 SOLENOID HEX NUT PRESSURE RELIEF PRESSURE REGLATOR HOUSING O-RING CLEAN-OUT PORT O-RING THUMB SCREW TEFLON GASKET (IINSIDE FITTING) PL-53523-E Fig.
– 20 – 5. The flexible diaphragm of the lid-locking device is visible when viewing the underside of the kettle lid. Make certain diaphragm material is not torn or punctured. If it is, contact your local Hobart service office for immediate replacement.
– 21 – Fig. 21 PL-40939-2 REMOVE BOL T Fig. 22 5. Remove 4 screws holding exhaust tank in place (see Fig. 21) and remove exhaust tank. 6. Flush exhaust tank with hot water. 7. Reverse procedure to reinstall exhaust tank. EXHA UST VENT 1-1/4" DIA.
– 22 – MAINTENANCE WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK.
– 23 – Cleaning Port Plug Screw The O-Ring seal on the cleaning port plug screw (Fig. 24) needs to be replaced if liquid is leaking around the screw. Fig. 24 VENT When fryer is off and cool, annually examine the flue and clear any obstructions. Contact personnel qualified to install and repair gas equipment for all other maintenance problems.
– 24 – POSSIBLE CAUSES 1. No product or very dry product loaded. 2. Power switch is in the OFF or FILTER position. 3. Lid not tightened. 4. Lid O-Ring not sealing. Replace O-Ring. 1. Dirty exhaust line to solenoid. 2. Dirty line from kettle pressure regulator to exhaust tank.
Ein wichtiger Punkt beim Kauf des Geräts Hobart HPGF15 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Hobart HPGF15 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Hobart HPGF15 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Hobart HPGF15 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Hobart HPGF15 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Hobart HPGF15 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Hobart HPGF15 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Hobart HPGF15. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Hobart HPGF15 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.