Benutzeranleitung / Produktwartung Refrigeration System H-IM-82B des Produzenten Heatcraft Refrigeration Produc
Zur Seite of 20
H-IM-82B July 2008 P ar t No . 25001901 Re frigeration S y st em Installa tion Refriger ation S y stem F or Outdoor Applications Installation and Opera tion Guide Replaces H-IM-82A (6/06) © 2008 Heatcraft Refrigeration Products LL C T able of C ontents 1.
2 1. Owner's Operating Instructions P er formanc e / Elec trical Data T able 3. Specications Model Refrigerant Refriger ant Charge (oz.) T otal Heat of Rejection (BTUH) Appro x.
3 25" x 25" panel opening required f or evaporator section of medium cabinet sizes . * 21.5" with weather hood. Figur e A. Medium Cabinet Dimensions without weather hood Models PT T 021, 031, 044, 047, 063, 072 Dimensional Diagrams Figur e B.
4 1. Owner's Operating Instructions Some general rules for the evaporat or section placement which must be follow ed are: 1. Ensure that the structural integrity of the box can withstand the weight of the top mounted equipment. 2. The air pattern must cov er the entire r oom.
5 1. Owner ’ s Op era ting Instructions T able 4. Contr ol F ac tory Default S ettings PT T Models T emperature Set Points Defrost Start T imes Defrost Duration (Maximum) Drip Time F an Delay Defrost T ermination Set Point Cooler Models All cabinet sizes 35˚F Every 3 hours of compressor run time 60 min.
6 1. Owner's Operating Instructions The Outdoor c omes standard with the following additional c omp onents: • Crankcase Heater • Drain Line Heater • W eather Hood • F an Cycling (Pressure on 1 fan models , Pressure and A mbient on 2 fan models).
7 1. Owner's Operating Instructions F igure 1. Curb placed on r oof of walk-in cooler . F igure 2. Roof membrane placed ov er curb. F igure 3. PT T unit placed on roof of walk -in color . (see rigging instructions). F igure 4. Weather hood installed after electrical ser vice connection.
8 Ser vice Inf ormation All units are designed for maximum dur ability , reliability and simplicity . comes to you ready f or operation, fully charged and with all controls pr eset at the factor y . T he following inf ormation is provided as an aid in the even t that service is required.
9 MAIN FUNCTIONS HO W T O S E E TH E SE T PO IN T 1. Push and immediately r elease the SE T key: the display will show the Set point value . HOW T O CHANGE THE SETPOINT 1. Push the SET key f or more than 2 seconds to change the Set point value; 2. The value of the set point will be displa yed and the LED starts blink ing; 3.
10 Reprinted with permission from Dixell . DISPLA Y CF T emperature measurement unit °C=Celsius; °F=F ahrenheit. W ARNING: When the measurement unit is changed the SET point and the values of the pa.
11 Reprinted with permission from Dixell . 3. Coolers Air Defrost Sequence of Oper ation for C o olers Air defrost units are pr eprogr ammed for 3 hours of compressor run time between defr osts. These periods are not reprog rammable. After 3 hours , the temperature c ontrol will turn the compressor o .
12 4. Ser vice Inf ormation T able 5. Sy stem T roubleshooting Chart PROBLEM POSSIBLE CAUSES POSSIBLE CORRECTIVE STEPS Compressor 1. Main switch open. 1. Close switch. will not run 2. F use blown. 2. Check electrical circuits and motor winding for shorts or grounds .
13 Replacement P ar ts by 4. Ser vice Inf ormation *Kits include control, sensors , mounting hardware and instructions. **PSC motor option (H designation on end of model name): part 25307801 = 25308601, par t 25307701 = 25308501, part 25303201 = 25399201, par t 25300101 = 25308501.
14 5. Wiring Inf ormation Cooler - Air Defr ost Sy stems - Single Phase Diagram 1. Wiring Diagram f or System, Air Defr ost 208-230/1/60 (B): Models PT T047H2B, PTT063H2B, PTT072H2B, PT T099H2B, and PTT128H2B. Medium and Large Cabinet Models Wiring . 208-230/1/60 voltages.
15 Diagram 2. Wiring Diagram f or System, Electric Defrost 208-230/1/60 (B): Models PT T021L6B, PTT031L6B, PTT044L6B, PT T052L6B, and PTT069L6B. Fr eezer - Electric Defrost Sy stems - Single Phase Medium and Large Cabinet Models Wiring . 208-230/1/60 voltages Indoor and Outdoor Models with Dixell XR-60C Con troller 5.
16 5. Wiring Inf ormation Diagram 3. Wiring Diagram f or System, Electric Defrost 208-230/1/60 (B): Models PT T021L6B, PTT031L6B, PTT044L6B, PT T052L6B and PTT069L6B.
17 Large Cabinet Models Wiring . 208-230/3/60 voltage. Diagram 4. Wiring Diagram f or System, Air Defr ost 208-230/3/60 (C): Models PTT099H2C and PT T128H2C. Cooler - Air Defr ost Sy stems - Three Phase YELLOW BLACK RT N L C BLACK BLUE BLACK BLUE -(3) Hours of compressor run time between defrosts.
18 Fr eezer - Electric Defrost Sy stems - Three Phase Diagram 5. Wiring Diagram f or System, Electric Defrost 208-230/3/60 ( C): Models PT T052L6C and PT T069L6C only .
19 RT -- ROOM THERMOST A T CFM -- CONDENSER F AN MOTOR CC -- COMPRESSOR CONT ACTOR EFM -- EV APORATOR F AN MOTOR LEGEND HL -- HEA TER LIMIT THERMOST AT DH -- DEFROST HEA TER GND -- GROUND RC -- RUN CA.
2175 W est P ark Place Blvd. • S tone Mountain, GA 30087 (800) 321-1881 • F ax: (770) 465-5990 • w ww .heatcraftrpd.com Since product improv ement is a continuing eort, we reserve the right to make changes in specications without notice .
Ein wichtiger Punkt beim Kauf des Geräts Heatcraft Refrigeration Products Refrigeration System H-IM-82B (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Heatcraft Refrigeration Products Refrigeration System H-IM-82B noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Heatcraft Refrigeration Products Refrigeration System H-IM-82B - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Heatcraft Refrigeration Products Refrigeration System H-IM-82B reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Heatcraft Refrigeration Products Refrigeration System H-IM-82B erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Heatcraft Refrigeration Products Refrigeration System H-IM-82B besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Heatcraft Refrigeration Products Refrigeration System H-IM-82B verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Heatcraft Refrigeration Products Refrigeration System H-IM-82B. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Heatcraft Refrigeration Products Refrigeration System H-IM-82B gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.