Dehumidifier Service Manual CAUTION -Before servicing the unit, read the "safety precautions" in this manual. -Only for authorized service personnel.
—2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ...........................................................................................................................3 1.2 FEATURES AND DIMENSIONS ......................................................
—3— 1. PREF A CE This Service Manual provides various service information, including the mechanical and electrical parts. This dehumidifier was manufactured and assembled under the strict quality control procedures. The refrigerant is charged at the factory.
—4— 1.3 SPECIFICA TIONS *NOTE: Specifications are subject to minor change without notice for further improvement. CAPACITY(Pints/24hrs) 30 50 65 POWER SUPPLY(Phase,V,Hz) 1Ø, 115V,60Hz INPUT(W) 560 560 800 RUNNING CURRENT(A) 5.1 5.4 7.6 ENERGY FACTOR(L/kw.
— 5 — 1 2 3 4 5 6 7 8 9 Off Max High Low Fan Speed Humidity Control Auto Shut-Off Humidity Control • When y ou first use the dehumidifier , tur n the humidity control to 5 or 6. If you still ha ve moisture , turn the humidity control to a higher setting.
— 6 — 1.5.1 HO W DOES THE DEHUMIDIFIER WORK? Moist, humid air is drawn over a cold refrigerated dehumidifying coil. Moisture in the air condenses on this coil and drains into a bucket (or through the bucket into a hose and drain).
—7— 1.5.5 HUMIDITY CONTROLLER 1.5.5.1 Mechanical Type The humidity control can be set anywhere between Off and Max for normal operation. If you need more dehumidification, turn the Humidity Control toward Max. If you need less dehumidification, turn the Humidity Control toward Off.
—8— 2. CIRCUIT DIA GRAM • MODEL : BHD-301- C Q'TY PER SET 1 1 1 1 1 1 1 1 1 1 1 RE- MARKS S S S S S S S S S S S 1 2 3 4 5 6 7 8 9 10 11 DESCRIPTION POWER CORD ASSEMBLY SWITCH, ROCKER MOTOR .
—9— W I R I N G W I R I N G D I A G R A M D I A G R A M M A I N P C B M A I N P C B C N - S / VA L V E C N - S / VA L V E C N - F A N C N - F A N R E V E R S I N G R E V E R S I N G C O I L C O I .
3.1 MECHANICAL P AR TS 3.1.1 BUCKET AND AIR FIL TER 1. Turn the Humidity Control off(Mechanical type) or press the power button off. (Electronic type) 2. Disconnect the power supply. 3. Remove the bucket. (See Figure 9) 4. Pull out the air filter. (See Figure 10) 3.
3.2 CONTR OL P ARTS 3.2.1 PO WER CORD ASSEMBL Y 1. After opening the control box, remove the screw that holds the ground wire. (See Figure 15) 2. Disconnect the remaining leads of the power cord from the PWB(PCB) ASSEMBLY, MAIN, then remove it from the control box.
— 12 — 3.2.6 COIL ASSEMBL Y , SOLENOID (BHD-501- B , BHD-651- C ) 1. Disconnect the housing of the COIL ASSEMBLY, SOLENOID from the PCB(PWB) ASSEMBLY, MAIN. 2. Remove the screw that fastens the COIL ASSEMBLY, SOLENOID. (See Figure 19) 3. Pull it out upwards.
3.2.8 F AN AND MO T OR 1. Turn the nut left and full out the Fan by hands carefully. 2. Remove 2 screws that fasten Heat Exchange. 3. Lift the H/E and open the H/E around 45 degree clockwise carefully. (See Figure 22) 4. Unfasten 3 screws that secure the Motor and earth wire.
—14— 3.3 REFRIGERA TING CYCLE 3.3.1 CONDENSER, EV APORA T OR AND CAPILLAR Y TUBE 1. Remove the insulation on the Heater/Evaporator (H/E) assembly 2.
—15— 1. When replacing a refrigeration component, be sure to discharge the refrigerant system by using a refrigerant recovery system. 2. After discharging the unit completely, remove the desired component, and unbraze the pinch-off tubes. 3. Solder service valves into the pinch-off tube ports, leaving the valves open.
— 16 — Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment. pinch-off tool capable of making a vapor-proof seal, leak detector, tubing cutter, hand tools to remove components, service valve.
CONDITION 1. Dehumidifier does not start. (Both compressor and fan motor do not operate.) 2. Motor runs but compressor does not run. 3. Does not defrost control. 4. Insufficient dehumidification CAUSE No power Poor plug contact at outlet. Bucket is full.
—18— CONDITION 5. Noisy operating 6. Water drips 7. Compressor cycles on overload protector. (OLP) CAUSE Fan Loose foreign material inside the housing. Tube hits frame. Fan blade hits frame Internal compressor noise. Loose set screws Worn bearings of Motor Assembly The bucket is not installed properly.
—19— 5. EXPLODED VIEWS • MODEL: BHD-301-C 131400 349600 149980 165010 346811 359012 264110 148391 144410 752140 152302 436500 249950 266010 130410 235512 149410 435300 330870 266003 238310 13531.
—20— • MODEL: BHD-501-B W0CZZ-2 165010 268711-2 264110 249950 35211A 352113 552204 567502 554160 550140 354210 554030 135312 131400 148391 144410 752140 152302 436500 130410 2 355 12 266010 2383.
—21— • MODEL: BHD-651-C W0CZZ-2 165010 268711-2 264110 249950 35211A 552204 352113 567502 554160 550140 354210 135312 554030 131400 349600 149980 346811 359012 148391 144410 752140 152302 436500.
—22— 6. REPLA CEMENT P AR TS LIST • MODEL: BHD-301-C 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A10285D 330870 DRAIN PAN ASSEMBLY 3087A10019C 14.
—23— • MODEL: BHD-501-B 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A18012C 330870 DRAIN PAN ASSEMBLY 3087A10019C 148391 TANK ASSEMBLY,BUCKET 483.
—24— • MODEL: BHD-651-C 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A18012C 330870 DRAIN PAN ASSEMBLY 3087A10019E 148391 TANK ASSEMBLY,BUCKET 483.
— 25 — MEMO.
— 26 — MEMO.
Specifications and performance data subject to change without notice. HEA T CONTROLLER, INC. 1900 WELL W OR TH A VENUE • JA CKSON, MICHIGAN 49203 THE QU ALITY LEADER IN CONDITIONING AIR P/No.
Ein wichtiger Punkt beim Kauf des Geräts Heat Controller BHD-501-B (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Heat Controller BHD-501-B noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Heat Controller BHD-501-B - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Heat Controller BHD-501-B reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Heat Controller BHD-501-B erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Heat Controller BHD-501-B besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Heat Controller BHD-501-B verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Heat Controller BHD-501-B. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Heat Controller BHD-501-B gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.