Benutzeranleitung / Produktwartung GEM42 des Produzenten Heat & Glo LifeStyle
Zur Seite of 29
1 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas • Do not try to light any appliance. • Do not touch any electrical switch.
2 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide .
3 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 TABLE OF CONTENTS Safety and W arning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes .
4 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante.
5 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 ITE M / PI ÈC E DESCRI PTI O N SE RIA L # / N° DE SÉRI E P A RT NUM BER / N° DE PI ÈCE 1 H e at Sh iel d / Pro t ect i on (Bou clier ) de C.
6 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 (NG , LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces Service Parts Intermittent Pilot Ignition V alve Assembly GEM42 Beginning Ma.
7 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 Appliance Certification The Heat & Glo fireplace model discussed in this Installers Guide has been tested to certification standards and listed by the applicable laboratories.
8 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 2 Getting St arted Introducing the Heat & Glo Gas Fireplaces Heat & Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
9 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 Figure 1. Diagram of the GEM42 TOP S TANDOFFS TO P VENT COLLARS TRIM DOOR RA TNG P LA TES AND LABELS GAS CONTROLS GAS LIN E ACCESS ELECT RICAL ACCESS HEA T- ZONE KNOCKOUTS HEA T-OUT KNOCKOUT ORI F IC E ACCESS P ANEL 3” (76.
10 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 3 Inst alling the Fireplace Step 1. Locating the Fireplace The following diagram shows space and clearance require- ments for locating a fireplace within a room. ABCD E 47-1/2” 18” 39” 55.
11 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 Framing should be constructed of 2 X 4 lumber or heavier . A . ................. 47-1/2” B . ................. 47-3/4” C . ................. 17-1/2” D . ........................ 6 5” E** .
12 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 NOTE: PIPES OVERLAP 1-1/4 INCHES A T EACH JOINT . Figure 4. DVP-Series Direct V ent Component Specifications (5-inch inner pipe / 8-inch outer pipe) D V P 9 0 S T 12- 9/1 6 11- 1 /4 7-1/4 1-1/4 TYP 1/2 TY P 8- 9/16 DVP3 6 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN.
13 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 Figure 5. V ent System Component s and T ermination Kit s Step 3. Inst alling the V ent System A. V ent System Approvals These models are approved to use DVP-series direct vent pipe components and terminations (see Figures 4 and 5).
14 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 FL UE RES TRIC TOR Figure 9 PILO T SHIEL D PIL OT BRACKE T PILO T SH IELD SHO U L D BE CLOS ED AN D T OUC HING THE P ILOT BR ACKET Figure 10 PI LOT SHIE LD BE ND P ILOT SHIE LD UP 3/8” TO AL LOW A IR FL OW TO FEED THE P ILOT FLAME Flue Restrictor Instructions 1.
15 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 VENTING WITH ONE (1) 90° ELBOW V (FT .) H (FT .) 2' MIN. (.609m) 3' MAX. (.912m) 2.5' MIN. (.762m) 6' MAX. (1.82m) 3.5' MIN. (1.06m) 9' MAX. (2.73m) 4.5' MIN.
16 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 VENTING WITH THREE (3) 90° ELBOWS V (FT .) H (FT .) 2' MIN. (.609m) 3' MAX. (.912m) 2.5' MIN. (.762m) 6' MAX. (1.82m) 3.5' MIN. (1.06m) 9' MAX. (2.73m) 4.5' MIN.
17 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 B. Inst alling V ent Components V enting Out the T op V ent The glass must be taken off again for positioning the logs when the unit is finally installed in place and finished around it. Re-install the glass door .
18 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 4. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes. NOTE: Model DVP-TRAP does not need an exterior fir- estop on an exterior combustible wall.
19 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 ! C. V ent T ermination For Horizont al T erminations - T o attach and secure the termination to the last section of horizontal vent refer to the Cinch Pipe and T ermination Cap installation instructions.
20 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 21. V ent T ermination Minimum Clearances A = 1 2" ....................... clearances above grade, veran- da, porch, deck or balcony B = 1 2" .
21 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 For V ertical T erminations - T o locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint. • Make the outline of the roof hole around the centerpoint nail.
22 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 Step 5. Installing the Optional Heat-Out or Heat-Zone Kits Figure 24 3. Cut and frame a 12” wide x 10” tall (305 x 254mm) hole in the exterior wall. The center of the hole will be 22-15/16” (583mm) above the base of the fireplace.
23 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 • At the gas line access hole, use insulation to re-pack the space around the gas pipe. • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.
24 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 ! ! Figure 26. Intermittent Pilot Ignition (IPI) Wiring Diagram NOTE 1: Ignition module, valve, pilot and wall switch operate on 3 volts. 120 V AC is required at junction box unless equipped with battery back-up.
25 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 FI NI SH W AL L MA TE RI AL M US T BE NO N-C OMB USTI B LE - T O P A ND SI DE S 60” 52 ” NON-COM B UST IBLE Step 10.
26 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 Facing Requirements Facing Thickness from 3/4” to 1-1/4” Facing material within this thickness range can be brought to 1/2” behind the door top and sides. These non-combus- tible finishing materials must never overlap or obstruct the air outlet/inlet grille areas.
27 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 Inst alling the T rim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face. The joints between the finished wall and the fireplace top and sides can only be sealed with a 300° F .
28 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace. Review safety warnings and cautions • Read the Safety and Warning Information section at the beginning of this Installers Guide .
29 Heat & Glo • GEM42 • 371-900 Rev . N • 2/05 4 Maint aining and Servicing Y our Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will de.
Ein wichtiger Punkt beim Kauf des Geräts Heat & Glo LifeStyle GEM42 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Heat & Glo LifeStyle GEM42 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Heat & Glo LifeStyle GEM42 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Heat & Glo LifeStyle GEM42 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Heat & Glo LifeStyle GEM42 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Heat & Glo LifeStyle GEM42 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Heat & Glo LifeStyle GEM42 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Heat & Glo LifeStyle GEM42. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Heat & Glo LifeStyle GEM42 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.