Benutzeranleitung / Produktwartung 36DV des Produzenten Heat & Glo LifeStyle
Zur Seite of 26
1 - Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. - What to do if you smell gas • Do not try to light any appliance. • Do not touch any electrical switch. • Do not use any phone in your building.
2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or components MA Y BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance.
3 TABLE OF CONTENTS Safety and Warning Information ................................................. 2 Service Parts Lists ...................................................................... 4 Section 1: Approvals and Codes ........................
4 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 12 Log set assembly (NG , LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces Service.
5 ITEM / PIÈCE DESCRIPTION PART NUMBER / N° DE PIÈCE 1 Log 1 / Bûche 1 SRV750-706 2 Log 2 / Bûche 2 SRV569-705 3 Log 3 / Bûche 3 SRV2012-161 4 Log 4 / Bûche 4 SRV2012-162 5 Log 5 / Bûche 5 SRV.
6 Appliance Certification The Heat-N-Glo fireplace model discussed in this Installers Guide has been tested to certification standards and listed by the applicable laboratories. Certification MODEL: ESCAPE-36DV LABORATORY: Underwriters Laboratories TYPE: Direct Vent Gas Fireplace Heater STANDARD: ANSI Z21.
7 2 Getting Started Introducing the Heat-N-Glo Gas Fireplaces Heat-N-Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
8 Figure 1. Diagram of the ESCAPE-36DV TOP VENT COLLARS RATNG PLATES AND LABELS GAS CONTROLS GAS LINE ACCESS Ø 8” (203mm) 20-7/8” (532mm) 25-3/8” (646mm) 1/2” (13mm) 12” (304mm) 3-1/2” (9.
9 3 Installing the Fireplace Step 1. Locating the Fireplace The following diagram shows space and clearance require- ments for locating a fireplace within a room. ABCD E 51-1/2” 22” 46-3/4” 66” 93-3/8” Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Front .
10 Framing should be constructed of 2 X 4 lumber or heavier. A . ......... 51-1/2” B . ................ 46” C . ................ 22” D . ........ 55-1/8”” E . .......... 54-1/8” Figure 3. Framing Dimensions Step 2. Framing the Fireplace Fireplace framing can be built before or after the fireplace is set in place.
11 NOTE: PIPES OVERLAP 1- 1/4 INCHES AT EACH JOINT. Figure 6. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) D V P 9 0 S T 12-9/16 11-1/4 7-1/4 1-1/4 TYP 1/2 TYP 8-9/16 DVP36 DVP48 48 24 36 4 6 DVP4 DVP6 12 DVP12 2 MIN.
12 Figure 7. Vent System Components and Termination Kits Step 3. Installing the Vent System A. Vent System Approvals These models are approved to use DVP-series direct vent pipe components and terminations (see Figures 6 and 7). Approved vent system components are labeled for identifi- cation.
13 FLUE RESTRICTOR Flue Restrictor Instructions 1. The flue restrictors (Figure 10) are located behind the right side panel. There is one each of the 3 ” diame t er and 2” diameter. Use the following table to determine which restrictor to use for the vent run.
14 VENTING WITH ONE (1) 90° ELBOW V (FT.) H (FT.) 1.5' MIN. (.457m) 2.5' MAX. (.762m) 2' MIN. (.609m) 3' MAX. (.912m) 2.5' MIN. (.762m) 6' MAX. (1.82m) 3.5' MIN. (1.06m) 9' MAX. (2.73m) 4.5' MIN. (1.37m) 12' MAX.
15 VENTING WITH THREE (3) 90° ELBOWS V (FT.) H (FT.) 1.5' MIN. (.457m) 2.5' MAX. (.762m) 2' MIN. (.609m) 3' MAX. (.912m) 2.5' MIN. (.762m) 6' MAX. (1.82m) 3.5' MIN. (1.06m) 9' MAX. (2.73m) 4.5' MIN. (1.37m) 12' MAX.
16 B. Installing Vent Components Venting Out the Top Vent The glass must be taken off again for positioning the logs when the unit is finally installed in place and finished around it. Re-install the glass door. Attach vent system to the top starting collars.
17 ! C. Vent Termination For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent refer to the Cinch Pipe and Termination Cap installation instructions. • Push and snap-lock the ends as described at the begin- ning of the Installing Vent Components section.
18 V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 20. Vent Termination Minimum Clearances A = 12" .......................... clearances above grade, ve ran- da, porch, deck or balcony B = 12" ...........
19 For Vertical Terminations - To locate the vent and install the vent sections: • Locate and mark the vent centerpoint on the underside of the roof, and drive a nail through the centerpoint. • Make the outline of the roof hole around the centerpoint nail.
20 Step 5. Installing the Optional Heat-Zone Kit Figure 23 Heat-Zone Kit 1 . Remove the knockout from the top of the fireplace and discard it (see Figure 23). 2. Center the duct collar around the exposed hole and at- tach it to the fireplace with 3 screws.
21 • At the gas line access hole, use insulation to re-pack the space around the gas pipe. • Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing .
22 ! ! Wall Switch You must use two wall switches with this unit. Position the wall switch in the desired position on a wall. Run a maxi- mum of 25 feet (7.8 m) or less length of 18 A.W.G. mini- mum wire and connect it to the fireplace ON/OFF brown switch wires.
23 12” 51” FINISH WALL NON-COMBUSTIBLE 12” 46-1/2” 51” FINISH WALL NON-COMBUSTIBLE Step 10. Finishing Figure 26 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the opening edge of the fireplace.
24 ! Facing Requirements Figure 28. Figure 29. COMBUSTIBLE O.K. COMBUSTIBLE O.K. NON-COMBUSTIBLE When finishing the front of the fireplace, combustible mate- rial must never overlap into the face of the unit. There are two different ways the unit can be set and fin- ished.
25 Step 12. Before Lighting the Fireplace Before lighting the fireplace, be sure to do the following: Remove all paperwork from underneath the fireplace. Review safety warnings and cautions • Read the Safety and Warning Information section at the beginning of this Installers Guide .
26 4 Maintaining and Servicing Your Fireplace Fireplace Maintenance Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season.
Ein wichtiger Punkt beim Kauf des Geräts Heat & Glo LifeStyle 36DV (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Heat & Glo LifeStyle 36DV noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Heat & Glo LifeStyle 36DV - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Heat & Glo LifeStyle 36DV reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Heat & Glo LifeStyle 36DV erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Heat & Glo LifeStyle 36DV besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Heat & Glo LifeStyle 36DV verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Heat & Glo LifeStyle 36DV. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Heat & Glo LifeStyle 36DV gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.