R1 P61A-2 ! Pellet ! S tove ! Owners ! Manual SA VE ! THESE ! INSTRUCTIONS. Inst allation ! & ! Operating ! Manual R5 ìCe ! manuel ! est ! disponible ! en ! FranÁais ! sur ! demandeî SAFETY ! NOTICE PLEASE ! READ ! THIS ! ENTIRE ! MANUAL ! BEFORE ! YOU ! INST ALL ! AND ! USE ! YOUR ! NEW ! ROOM ! HEA TER.
2 P61A !! Pellet ! Stove Fig. ! 1.
3 P61A ! Pellet ! Stove T esting ! Lable 2 Assembly ! & ! Installation 4 Installation 5 V enting !!!!!!!!!! 6 Automatic ! Operation 1 2 ESP ! Control 1 6 Maintenance 1 7 T rouble ! Shooting 2 2 Fe.
4 P61A !! Pellet ! Stove !!!!! ! ! Assembly ! and ! Installation Unpacking The ! P61 ! is ! bolted ! to ! the ! skid ! to ! prevent ! movement during ! shipping. To ! free ! the ! stove ! from ! the ! skid ! you ! must ! remove the ! hold-down ! bolts ! in ! the ! rear ! of ! the ! pedestal ! base.
5 P61A ! Pellet ! Stove Installing Place ! the ! stove ! on ! a ! noncombustible ! floor ! protector that ! extends ! 6 ! inches ! to ! the ! front, ! 6 ! inches ! to ! the ! sides and ! 1 ! inch ! to ! the ! rear ! of ! the ! stove. ! The ! minimum ! floor protector ! material ! is ! 24 ! gauge ! sheet ! metal.
6 P61A !! Pellet ! Stove V enting Requirement s ! for ! T erminating ! the ! V enting W ARNING: ! V enting ! terminals ! must ! not ! be ! re- cessed ! into ! a ! wall ! or ! siding. NOTE: ! Only ! PL ! vent ! pipe ! wall ! pass-throughs and ! fire ! stops ! should ! be ! used ! when ! venting ! through combustible ! materials.
7 P61A ! Pellet ! Stove V enting A ! combustion ! blower ! is ! used ! to ! extract ! the ! com- bustion ! gases ! from ! the ! firebox. ! This ! causes ! a ! negative pressure ! in ! the ! firebox ! and ! a ! positive ! pressure ! in ! the venting ! system ! as ! shown ! in ! fig.
8 P61A !! Pellet ! Stove #2 ! Preferred ! method This ! method ! also ! provides ! excellent ! venting ! for normal ! operation ! but ! requires ! the ! stove ! to ! be ! installed farther ! from ! the ! wall.
9 P61A ! Pellet ! Stove #4 ! Installing ! into ! an ! existing chimney ! ( ! US ! only ! ) This ! method ! provides ! excellent ! venting ! for ! normal operation. !! This ! method ! also ! provides ! natural ! draft ! in the ! event ! of ! a ! power ! failure.
10 P61A !! Pellet ! Stove #6 ! Installing ! into ! an ! existing fireplace ! chimney ! ( ! US ! and Canada ! ) This ! method ! provides ! excellent ! venting ! for ! normal operation. !! This ! method ! also ! provides ! natural ! draft ! in the ! event ! of ! a ! power ! failure.
11 P61A ! Pellet ! Stove #8 ! Installing ! through ! the ! ceiling ! vent Through ! the ! ceiling ! vent, ! follow ! PLvent manufacturers ! recommendations ! when ! using ! wall ! and ceiling ! pass ! through. Fig. ! 14 No ! insulation ! or other ! combustible materials ! are allowed ! within ! 3" of ! the ! PL ! vent ! pipe.
12 P61A !! Pellet ! Stove The ! P61A ! pellet ! stove ! is ! more ! than ! just ! automatic ! ignition, ! it ! is ! also ! automatic ! temperature ! control. The ! automatic ! system ! will ! allow ! the ! fire ! size ! to ! be ! adjusted ! to ! match ! the ! heating ! needs ! and ! even ! put the ! fire ! out ! if ! necessary .
13 P61A ! Pellet ! Stove Starting ! First ! Fire Ignitor ! Switch ! to"AUTO"(up ! position) Make ! sure ! the ! unit ! is ! plugged ! into ! a ! 120 V AC, ! 60 ! HZ ! electrical ! source. ! The ! power ! light should ! be ! the ! only ! light ! lit.
14 P61A !! Pellet ! Stove The ! P61A ! Pellet ! Stove ! is ! capable ! of ! manual ! operation. ! This ! also ! allows ! the ! operator ! to manually ! control ! operation ! during ! an ! emergency ! (i.e. ! ignitor ! failure, ! when ! using ! a ! 502H ! battery backup, ! or ! when ! using ! certain ! generators.
15 P61A ! Pellet ! Stove P61A-2 !! MANUAL !! ST ART !! UP Starting ! First ! Fire Ignitor ! Switch ! to"MANUAL" (down ! position) Make ! sure ! the ! unit ! is ! plugged ! into ! a 120 ! V AC, ! 60 ! HZ ! electrical ! source. ! The power ! light ! should ! be ! the ! only ! light ! lit.
16 P61A !! Pellet ! Stove O O P61A-2 !! AUTOMA TIC ! IGNITION !! ESP !! CONTROL Feed ! adjuster Sets ! the ! maximum ! feed rate T est Runs ! all ! motors ! at ! full speed ! for ! one ! minute to ! check ! operation.
17 P61A ! Pellet ! Stove These ! units ! are ! pre-tested ! at ! the ! factory ! with ! exactly 120 ! V olts ! A.C., ! 60 ! Hz. ! They ! are ! checked ! and ! adjusted !! for firebox ! tightness, ! gasket ! leakage, ! motor ! operation ! and ! ignitor operation.
18 P61A !! Pellet ! Stove The ! room ! sensor ! is ! a ! small ! temperature ! sen- sor ! on ! the ! end ! of ! a ! 60" ! gray ! wire. ! This ! sensor ! is installed ! much ! like ! a ! standard ! wall ! thermostat.
19 P61A ! Pellet ! Stove Removing ! Ashes: When ! approximatly ! 1 ! ton ! of ! pellets ! has ! been burned ! it ! will ! be ! necessary ! to ! empty ! the ! ash ! pan. Ashes ! should ! be ! placed ! in ! a ! metal ! container with ! a ! tight ! fitting ! lid.
20 P61A !! Pellet ! Stove Latch ! "closed ! "with blower ! cover ! in ! place. Burn ! pot ! clean-out ! is closed. Latch ! "open ! "with ! blower cover ! partly ! removed. Burn ! pot ! clean-out ! is open. Exposed !! blower ! wheel and ! flue ! opening, NOTE: ! ESP ! probe ! is visible.
21 P61A ! Pellet ! Stove Burn ! Pot ! Cleaning ! and ! Maintenance 1. !! Scrape ! the ! top ! holed ! surface ! and ! sides ! of ! the ! burn pot.(Fig !! 34) ! It ! is ! not ! necessary ! to ! completely ! remove all ! material ! from ! the ! burn ! pot.
22 P61A !! Pellet ! Stove !! FEEDER ! DOES ! NOT ! FEED 1. ! No ! pellets ! in ! hopper . 2. ! Firebox ! draft ! may ! be ! too ! low ! for ! low ! draft ! pressure switch ! in ! feeder ! circuit ! to ! operate. ! Check ! for ! closed doors , ! loose ! or ! missing ! gasket ! on ! doors ! or ! hopper ! lid, faulty ! pressure ! switch.
23 P61A ! Pellet ! Stove W eight 24 9 ! lbs. Blower 13 5 ! cfm Feed ! Rate .75 ! to ! 7.5 ! lbs. ! per ! hr . Hopper ! Capacity 7 2 ! lbs. Fuel W o od ! Pellets Flue ! Size 3 ! inch Outside ! Air ! Size 2 ! 3/8 ! I.D. ! inch Fuse ! Rating 5 ! amp 32.375" 9" 23.
24 P61A !! Pellet ! Stove Door ! Options Optional ! T rim To ! install, ! lay ! the ! frame ! face ! down ! on ! a ! sof t surface. !! Fasten ! door ! frame ! by ! inserting ! the ! 4 threaded ! post s ! on ! the ! frame ! through ! the ! door .
25 P61A ! Pellet ! Stove OPTIONS Side ! Heat ! Shields Side ! heat ! shields ! are ! available ! to ! reduce the ! clearance ! to ! combustible ! materials. Hopper ! Extension The ! hopper ! extension ! allows ! you ! to put ! more ! pellet ! fuel ! in ! the ! hopper ! and ! extends burn ! time ! on ! one ! load ! of ! pellets.
26 P61A !! Pellet ! Stove P61A-2 ! Wiring ! Diagram.
27 P61A ! Pellet ! Stove Description Part ! Number Hopper ! Gasket(6 ! ft.) 0-88-00248 Ash ! Pan ! Assembly 1-10-05800 Burn ! Pot ! Weldment 1-10-05802 Right ! Rear ! Shield 2-00-06468-1 Left ! Rear !.
28 P61A !! Pellet ! Stove Harman ! S tove ! Company ! warrants ! its ! products ! to ! be ! free ! from ! defects ! in ! material ! or ! workmanship, ! in ! normal ! use and ! service, ! for ! a ! per.
Ein wichtiger Punkt beim Kauf des Geräts Harman Stove Company P61A-2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Harman Stove Company P61A-2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Harman Stove Company P61A-2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Harman Stove Company P61A-2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Harman Stove Company P61A-2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Harman Stove Company P61A-2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Harman Stove Company P61A-2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Harman Stove Company P61A-2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Harman Stove Company P61A-2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.