Benutzeranleitung / Produktwartung DVC-500 des Produzenten Harman Stove Company
Zur Seite of 36
R1 .
2 This appliance is also approved for installation into a shop. LISTED SOLID FUEL BURNING ROOM HEA TER - MODEL: “DVC 500” Serial Number: WHI- W/N 03625 .
3 INDEX W arnings 4 Introduction 5 Assembly 6 Installation 7 DVC500 Microprocessor Control 15 Operation 17 Maintenance 19 Fuel 23 W iring Diagram 25 Control and Safety Sensors 26 Parts 27 Specications 30 T roubleshooting 31 Please read this entire manual before you install and use your new room heater .
4 Always empty th e hopper when not bu rning for more than a week. When left standing for long periods with wet coal, the pusher block will rust and corrode, causing it to seize. If the stoker is then turned "on", damage to the pusher assembly and feed motor could r esult.
5 INTRODUCTION This remarkable design by Harman features the V erti-ow Direct V ent Stoker System. This unique, high efciency unit uses only outside air for combustion. Micro-processor controls provide for an au- tomatic wide range of heat output from 7,000 to 75,000 BTU .
6 Assembly 1. Install the hopper latch as shown at left. 2. Install 3 rebricks on the cast iron angle behind the grate as shown. 3. Cement in grates as shown below .
7 4 GLASS RE- T AINER CLIPS 4 GLASS RET AINER BOLTS GLASS GLASS GASKET DOOR HINGE PINS BRASS HANDLE HANDLE BOLT WOOD HANDLE P A W BOLT SET SCREW V iewing glass The glass in your Harman stove is a special ceramic glass. • Do not abuse the glass by striking or slamming the door .
8 T ips On Installation Before the positioning of the unit can be de- cided a few questions should be considered? 1. Can the unit be vented properly and installed safely? 2. W ill exhaust be vented where fumes can build up or be drawn into lower levels of the structure 3.
9 7. Check the exterior of the termination for best t and screw to exterior and caulk with high grade exterior caulking. 8. Complete any other exterior ue piping neces- sary , using 4" pellet venting. 9. Back inside, place the 2 halves of the interior wall trim plate over ue pipe.
10 Installation.
1 1 Basement Installation T o install a DVC 500 in a basement you will need additional DVC vent sections. These sections are made with a 316-grade stainless steel liner and a 20 gauge galvaneeled outer shell. Each joint is sealed with a gasket and is bolted together with 4 bolts.
12 Installation.
13 Installation.
14 Installation Harman Dir ect V ent Coal Flue Pipe V enting System 1" Clearance to Combustibles Exterior T ermination for wall thickness up to 8 inches 1-10-08310 Exterior T ermination for wall .
15 ESP CONTROL Feed Adjuster Sets the maximum feed rate, 1 to 5 T est Runs all motors at full speed for two minutes to check operation. After two minutes the feeder stops and the distribution blower alternates fr om high to low every four seconds to r emind you that you ar e still in "T est Mode".
16 ESP Contr ol Hopper Lid Latch Ash Door Latch Handle Glass Door Latch Handle Side Panel Latch.
17 T esting Operation: T urn the Feed Adjuster to "T est" mode, (g. 13.) This will cause all motors to run 100% for 2 minutes. The lights on the control panel will be lit for each motor . If you leave it on "test" the blowers will cycle as an audible reminder .
18 This setting will pr oduce medium heat with the Dis- tribution Blower on "low". This setting will pr oduce a room temperatur e of 70 de- gr ees with the Distribution Blower at "medium" speed. This setting will pr oduce continuous maximum heat output with the Distribution Blower at full speed.
19 W ARNING OPENING THE VIEWING DOOR OR ASH DOOR WITHOUT TURNING THE FEED ADJUSTER T O THE "ASH OUT" POSITION MA Y CAUSE COMBUSTION GASES AND FL Y ASH T O ESCAPE. Ash Out Position Fig. 18 Removing Ash While Unit Is Burning: CAUTION: ASH P AN HANDLE WILL BE HOT , WEAR GLOVES .
20 WEEKL Y MAINTENANCE FINES TRA Y COVER Empty Fines T ray The small Fines Tray in the side of the stoker should be removed and emptied T o remove the Fines T ray , rst open the door on the left rear of the stove. Next, loosen the thumb screws holding the Fines T ray Cover , g# 20.
21 A 3-month cleaning will give you a base line as to how often your DVC500 needs to be cleaned. Cleaning intervals will differ in each installation because of the ash and moisture content of the coal and the amount of coal burned. NOTE: Unit should be off & cooled down enough to perform these maintenance items: 1.
22 The End Of Season Shut Down List. 1. Allo w th e s tove to ru n ou t o f co al in orde r t o ex tin- gu ish the re . T his save s hav in g to rem ove the co al from the hopper manually and most importantly , drives the moisture out of the stove that may be present in the coal.
23 Motors Fuel The DVC500 is designed to burn Anthracite Rice Coal, which is approximately 3/8" long and wide by 3/16 thick. Anthracite coal is considered either White Ash or Red Ash. White Ash Coal will have 13 to 14,000 btu's per lb. White ash coal usually has less ash and will burn longer .
24 The DVC500 grate system is composed of four pieces: the grate holder, (2)-63 hole grate inserts, and grate angle. The grate angle is bolted to the grate holder with (2) 3/8 x 1 1/4 bolts. Before installing the grate holder , 3/8" round gasket must be checked in the groove on the bottom side of the grate holder , as shown in Fig 31.
25 Maintenance Schedule It is recommended that End of Season Cleaning and the Annual Service are coordinated to happen at the same time for best results.
26 Control and Safety Sensors ESP The ESP (Exhaust Sensing Probe) is a temperature sensing probe located in the exhaust outlet. The ESP works with the Control to perform all burn rate func- tions as well as high and low limit control.
02/1 1 .
02/1 1 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
02/1 1 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
30 Specications W eight 500 Pounds BTU Output Range 7000 to 75,000 Heating Capacity 2200 Square Feet Fuel Anthracite Rice Coal Hopper Capacity 93 Pounds Distribution Blower Size 135 cfm Flue 4".
31 2 Blink Status Details: DVC 500-C Firebox Static Pr essure Safety Protocol The DVC-500 operates with a negative pressure rebox as a safety feature. The control continuously adjusts the draft motor speed to maintain a safe re- box negative static.
32 Cau se s A nd /Or Re aso ns For (2 -bl in k) Shu td own : The DVC-500 operates with a negative pressure rebox as a safety feature. Any loss of this negative pressure will start the safety protocol, ( A two blink status warning ) The following list of potential reasons for warnings is in order of most likely to least likely to occur: 1.
33 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer .
34 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor . A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation.
35 .
Proudly P rinted On 100% Recycled P aper.
Ein wichtiger Punkt beim Kauf des Geräts Harman Stove Company DVC-500 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Harman Stove Company DVC-500 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Harman Stove Company DVC-500 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Harman Stove Company DVC-500 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Harman Stove Company DVC-500 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Harman Stove Company DVC-500 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Harman Stove Company DVC-500 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Harman Stove Company DVC-500. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Harman Stove Company DVC-500 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.