990-5022A, Revision 2 6/99 PowerStack 450 Quick Reference Guide English About Your New PowerStack UPS This Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags and surges from reaching your computer and other valuable electronic equipment.
990-5022A, Revision 2 6/99 Table of Contents Safety .......................................................................................................................................................................................................
.
990-5022A, Revision 2 6/99 1 Safety This section contains important instructions that should be followed during installation and maintenance of the PowerStack 450 and batteries. It is intended for customers who setup, install, relocate, or maintain APC equipment.
990-5022A, Revision 2 6/99 2 • Do not use a ramp inclined at more than 10 ° . • This equipment is intended for installation in a temperature-controlled (0 ° - 40 ° C) indoor area, free of conductive contaminants.
990-5022A, Revision 2 6/99 3 Initial Inspection Inspect the APC PowerStack 450 UPS upon receipt. Notify the carrier and dealer if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly.
990-5022A, Revision 2 6/99 4.
990-5022A, Revision 2 6/99 5 Setup Note: The UPS will not power up initially unless the AC voltage is in the normal operating range. Rear View Plug the power cord into the power supply. Connect equipment to the output receptacles. • Do not power laser printers through the UPS.
990-5022A, Revision 2 6/99 6 LEDs and Audible Alarms The on-line LED illuminates when the UPS is supplying utility power to the loads. On Battery During on-battery operation, the on-battery LED illuminates and the UPS sounds an audible alarm consisting of four beeps every 30 seconds.
990-5022A, Revision 2 6/99 7 Operating Modes Shutdown Mode In shutdown mode the UPS stops supplying power to the load, waiting for the return of utility power. If there is no utility power present, external devices (e.g., servers) connected to the computer interface can command the UPS to shut down.
990-5022A, Revision 2 6/99 8 Replacing the Battery Pack This UPS has an easy to replace hot-swappable battery pack. Note: Please read the cautions in the APC Safety Guide . Replacement Batteries See your dealer or call the number in this manual for information on replacement battery pack kits, order RBC18 .
990-5022A, Revision 2 6/99 9 Specifications Acceptable input voltage 0 - 150 VAC Input voltage (on-line operation) Nominal Range Maximum Range User adjustable through PowerChute® plus . 74-119 VAC 69-126 VAC Output voltage) Nominal Range Maximum Range User adjustable through PowerChute® plus .
990-5022A, Revision 2 6/99 10 9. Include a letter with your name, RMA#, address, copy of the sales receipt, description of the trouble, your daytime phone number, and a check (if necessary). 10. Mark the RMA# on the outside of the package. 11. Return the UPS by insured, prepaid carrier to the address given to you by Customer Service.
Ein wichtiger Punkt beim Kauf des Geräts American Power Conversion 450 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie American Power Conversion 450 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für American Power Conversion 450 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von American Power Conversion 450 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über American Power Conversion 450 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon American Power Conversion 450 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von American Power Conversion 450 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit American Power Conversion 450. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei American Power Conversion 450 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.