Benutzeranleitung / Produktwartung AC182ACEAA des Produzenten Haier
Zur Seite of 23
Operation & Installation Manual CONVERTIBLE TYPE AIR CONDITIONER Please read this operation manual before using the air conditioner . Please keep this manual carefully and safely .
Contents Cautions ............................................................................... Safety Precautions .................................................................. Name of Parts .....................................................
1 Cautions For the purpose of safety , the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before opening inlet grill. Always grip plug firmly and pull straight out from the outlet.
Cautions T emperature and Humidity Range If the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate to prevent internal circuit damage.
Safety Pr ecautions W ARNING! If the power supply cord of this air conditioner is damaged, it must be replaced by the manufacturer or its authorized service personnel only . Use copper wire only. All the cables shall have got the Local authentication certificate.
4 Name of Parts Fig.1 Indoor Unit 1 4 6 7 3 Fig.2 POWER OPER TIMER COMP EMER 2 3 9 8 Fig.1 1 1 10 Note : For the wired control type unit, the unit state should be checked by the the wired controller , instead of the remote receiver; and if you set the TIMER function, the TIMER LED on the remote receiver will not be on.
Cleaning and Car e CAUTION! Before cleaning the air conditioner ,be sure to turn it off and disconnect the Power Supply Cord. Be sure the Intake Grill is installed securely . When removing and replacing the air filters, be sure not to touch the heat exchanger , as personal injury may result.
Operation and Performance *Heating Performance *Microcomputer-contr olled Automatic Defr osting Heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the room is heated.
Installation W ARNING ! CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air -conditioner .
8 Installation Pr ocedures Under ceiling Outdoor unit Indoor unit 2 cm or more Ceiling Indoor unit 30 cm or more Left Right 1.5m Floor console 30 cm or more 30 cm or more 1.5m 1.5m Left Right may be difference SELECTING THE MOUNTING POSITION (1)Do not install where there is the danger of com- bustible gas leakage.
Installation Pr ocedures Open the intake grill and remove the three or four or six screws.(Fig. 1) Remark: The main unit can be wired before the indoor unit is installed. Select the most appropriate installation order . A. FLOOR CONSOLE TYPE 1. DRILLING FOR PIPING Select piping and drain directions.
Installation Pr ocedures Select whether the drain hose will be connected to the left or right side.(Fig.3) Insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener . (Fig.6) 2. INST ALLING DRAIN HOSE (Fig. 6) W rap the insulation (drain hose) around the drain hose connection.
Fig. 15 3. INST ALLING BRACKETS Install the brackets with nuts, washers and spring washers.(Fig. 15) Spring washer Special nut Bracket 4. INST ALLING INDOOR UNIT Bracket (Right) Bracket (Left) Installation Pr ocedures Select piping and drain directions.
12 Installation Pr ocedures Select whether the drain hose will be connected to the left or right side.(Fig.3) Insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener .(Fig.6) W rap the insulation (drain hose)around the drain hose connection.
Installation Pr ocedures HOW TO CONNECT WIRING T O THE TERMINALS A. For solid core wiring (or F-cable)(Fig.24A) (1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the exposed solid wire. (2) Using a screwdriver , remove the terminal screw(s) on the terminal board.
14 Installation Pr ocedures ELECTRICAL REQUIREMENT Electric wire size and fuse capacity: T able 5 ELECTRICAL WIRING 1. INDOOR UNIT SIDE (1) Remove the electric component box. (2) Pull out the electric component box. Fig.28 (3) Remove the electric component box cover .
Installation Pr ocedures ELECTRICAL WIRING (1) The power sour ce capacity must be the sum of the room air conditioner curr ent and the current of other electrical appliances. When the current contracted capacity is insufficient, change the contracted capacity .
Installation Pr ocedures (2) Insert the hinges on the bottom of the intake grill into the holes in the base assembly . Then mount the arms to the three areas on the top of the intake grill. Fig. 35 Fig. 34 (1) Cut the right side of the intake grill. This is only when the pipe exits from the right side 3.
Followings are not problems Sound of water flowing is not a problem. Sound of cracking is heard. Smell are generated. During operation, white fog or steam comes out from the indoor unit. No outlet air or fan speed can't be changed in dry mode. In cooling operation, unit switches to blowing operation.
Before ask for services, please first check your unit against the following. Air conditioner won't start. Poor cooling or heating Is power supply switch turned on? Power supply switch is not set at ON.
19 T r ouble Shooting Error display ( For *.ERA ) Resumable if lower than 100 degree For remote type, flash times 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 20 21 Failure description Indoor ambient temp. sensor failure Indoor coil temp. sensor failure Outdoor ambient temp.
Resumable if lower than 100 degree Error display ( For *.EAA ) T r ouble Shooting 20 For remote type, flash times 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 20 Failure description Indoor ambient temp. sensor failure Indoor coil temp. sensor failure Outdoor ambient temp.
HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P .
Ein wichtiger Punkt beim Kauf des Geräts Haier AC182ACEAA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Haier AC182ACEAA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Haier AC182ACEAA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Haier AC182ACEAA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Haier AC182ACEAA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Haier AC182ACEAA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Haier AC182ACEAA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Haier AC182ACEAA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Haier AC182ACEAA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.