Benutzeranleitung / Produktwartung AB424FCAHA des Produzenten Haier
Zur Seite of 31
Please read this operation manual before using the air conditioner . No.0010576722A Indoor Unit Operation & Installation Manual CASSETTE TYPE AIR CONDITIONER Please keep this manual carefully and safely .
Contents Cautions ........................................................................................... Part name of the unit ........................................................................ Maintenance ..................................
Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal.
4. The wiring method should be in line with the local wiring standard. 5. The power cable and connecting cable are self-provided. The requirement of the power cable: H05RN-F 3G 1.5mm 2 The requirement of the connecting cable: All the cables shall have got the European authentication certificate.
3 W ARNING! Carefully r ead the following information in order to operate the airconditioner correctly . Below are listed three kinds of Safety Cautions and Suggestions. W ARNING! CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences.
4 CAUTIONS! Conditioner should not be used for any other purpose other than air conditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged.
5 W ARNING ! CAUTION ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air -conditioner .
Intr oduction to Spar e Parts 6 Drain Hose Swing fender Refrigerant pipe Cable line Earthing line Air filter Outlet Suction grill (located in the suction grill) In cooling operation, to discharge the water from inside the room.
7 3. Dismantle air filter CAUTION! 4. Clean 6. Close inlet grill (A) Remove dust with vacuum filter . 5. Install air filter (1) Put filter into protruding parts at the top of the inlet grill. (2) Connect the two pothooks with inlet grill See 2 [Clean inlet grill] 1.
8 3. T ake of inlet grill 4. Clean CAUTION! NOTE When the filter too much dust T o spray the special detergent for vent fan or utensils. 5. Install inlet grill 6.
9 NOTE The inner part of indoor unit must be cleaned. Consult dealer , because clean must be done by technician. In cooling operation, discharging system discharge water in r oom. 2. 1. Seasonal Reserve Operate the unit with F AN mode on a fair day for about half a day to dry the inside of the unit well.
10 The followings are not malfuncition Hua Hua T r ouble Shooting W ater flowing sound is heard When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds Bi- Bi- or Godo-Godo.
11 **? ON OFF T r ouble Shooting Air does not blow or the fan speed cannot be changed during drying. In DR Y mode, when room temperature becomes 2 C higher than temperature setting, unit rill run intermittently at LO speed regardless of F AN setting During heating,indoor fan is still running even unit is stopped.
12 When T rouble Happens Insufficient cooling or heating The operation controller adjusted as required Air filter too dirty ? Horizontal swing louver upward ? (in HEA T mode) Any obstacle exists at th.
13 When T rouble Happens 1. Error display Indoor unit malfunction display code Please keep this manual carefully and safely . Out door unit malfunction display code When the wire remote controller display E1,Can check the outdoor unit control board LED1 or out door unit malfunction display code to sure outdoor unit malfunction.
14 Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner .
15 A B C D E F Installation tools Standard accessories 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner ,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 1 1.
16 Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock. Be sure to install a leakage breaker to avoid electric shock. Arrange water drainage according to this Manual.
(2) Ceiling height Indoor unit can be installed on ceiling of 2.5-3m in height. (Refer to Field setting and Installation Manual of ornament panel.) (3) Install suspending bolt. Check if the installation place is strong enough to hold weight. T ake necessary measures in case it is not safe.
3. PREP ARA TION FOR THE INST ALLA TION (1) Position of ceiling opening between unit and suspending bolt. 3 18 AB424FCAHA AB484FCAHA (2) Cut an opening in ceiling for installation if necessary . (when ceiling already exists.) (3) Install a suspending bolt.
19 4. INST ALLA TION OF INDOOR UNIT In the case of new ceiling < After installation on the ceiling > (3) Adjust unit to its right position. (Refer to preparation for the installation-(1)) (4) Check unit's horizontal level.
6. INST ALLA TION OF W A TER DRAINAGE PIPE ( As for outdoor piping, please refer to installation Manual of outdoor unit. ) 5. REFRIGERANT PIPING Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit.
7. INST ALLING THE DECORA TED BOARD ON THE BODY OF INDOOR UNIT 6 7 21 4 2 2 1 3 As shown in Fig. 1, make the wind deflector motor of the decorated board face to the orifice of the indoor unit, and then mount the decorated board onto the body of the indoor unit.
22 W iring of Decorated Board a. Connect it to the connector of the wind deflector motor lead on the decorated board (Fig. 5); b. Connect it to the receiving terminal of remote control on the decorated board.
23 Mounting Air Inlet Grid and Angle Covers (1) Mounting the air inlet grid: T ake care not to wind the lead of the wind deflector motor during mounting the air inlet grid. (2)For Model AB184-484FCAHA units, the angle covers should be mounted on the angles.
24 Piping Materials & Heat Insulating Materials As to prevent condensation, heat insulating treatment should be performed. The heat insulating treatment for piping should be done respectively . Piping Material Heat Insulating Material Hard PVC tube VP31.
25 Installation Pr ocedur e T ubing Permissible Length & Height Difference Please refer to the attached manual of outdoor units. T ubing Materials & Specifications Refrigerant Filling Amount Add the refrigerant according to the installation instruction of outdoor unit.
AB094F AAHA AB124F AAHA AB184F AAHA AB244F AAHA AB424F AAHA AB484F AAHA AU52LFIAHA Electrical W iring C1 C2 R R C1 C2 R ST N Lm1 Lm2 Note: 1:L(black) 2:N(white) 3:C(red)----It's no use for Builtin EEV T ype on the indoor unit .
Matrix of the dial switch and indoor unit number Field setting Field setting the unit number Indoor unit number setting Indoor unit number setting switch and confirmation of the settings. There is a 4-position dial switch for setting the indoor unit number and fan speed level on the computer board of the indoor unit.
Item to the checked Pay special care to the following and check after installation Unproper installation may cause Check Is gas leakage check performed? Is unit properly insulated? Is water drainage s.
heating Capacity 710*440*270 710*440*270 840*840*240 840*840*240 860*500*60 860*500*60 950*950*80 950*950*80 42dB(A) 37dB(A) heating Capacity 950*950*80 950*950*80 6.35/12.7 6.35/12.7 9.52/15.88 9.52/15.88 9.52/19.05 9.52/19.05 29 Cooling Capacity Model Power Supply 7200W 8000W 1PH.
Ein wichtiger Punkt beim Kauf des Geräts Haier AB424FCAHA (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Haier AB424FCAHA noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Haier AB424FCAHA - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Haier AB424FCAHA reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Haier AB424FCAHA erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Haier AB424FCAHA besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Haier AB424FCAHA verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Haier AB424FCAHA. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Haier AB424FCAHA gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.