P200E Shuttle & RAPS200E Airpot/Shuttle Br e w er Series Operation and Instruction Manual Installation W ARNING: ELECTRIC SHOCK HAZARD! INST ALLA TION OF THIS APPLIANCE SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL ONL Y . IMPROPER INST ALLA TION COULD RESUL T IN ELECTROCUTION.
.
Page 2 P200/RAPS200 Brewers Installation (con't.) Electric hook-up 1) The electric ratings for your brewer are printed on its nameplate. T ypical electric ratings are: 120V , 1.65 kW , 15 Amp, 1 phase. 2) The brewer should be connected to its own circuit with a fused disconnect switch or a circuit breaker near the brewer .
Page 3 Operation CAUTION: HOT LIQUID HAZARD W A TER USED FOR BREWING COFFEE IS VER Y HOT . USE CAUTION WHEN BREWING , POURING , OR TRANSPORTING COFFEE. ACCIDENT AL SPILLS MA Y RESUL T IN SEVERE BURNS. 1) Place an empty , warm Shuttle under the brew head.
Page 4 Adjustment s W ARNING: ELECTRIC SHOCK HAZARD DANGEROUS ELECTRIC VOL T AGES ARE PRESENT NEAR ADJUST ABLE COMPONENTS. ALL ADJUSTMENTS SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL ONL Y . All adjustable component s are located under the top cover .
Page 5 Thermost at Adjustment The thermostat controls the water temperature in the t ank. Factory setting is 195 degrees F . This is the ideal temperature for brewing coffee. W ater should never boil in the tank. If water is boiling in the tank, adjust the temperature appropriately .
Page 6 Weekly or Bi-W eekly , Depending on Use (P200 Only): 1) Fill Shuttle with one gallon of hot water . 2) Pour the recommended concentration of urn cleaner into the Shuttle liners (Excessive amounts of cleaner will attack the st ainless steel). Urn cleaners that have been used successfully: DIP-IT , manufactured by Economics Laboratories, Inc.
Page 7 P200/RAPS200 Brewers T o Drain The Water T ank CAUTION: HOT LIQUIDS / BURN HAZARD W A TER IN T ANK IS VER Y HOT . USE CAUTION WHEN DRAINING T ANK. ACCIDENT AL SPILLS MA Y RESUL T IN SEVERE BURNS. 1) Shut off power to brewer . 2) Remove the top panel.
Page 8 T roubleshooting: Filling, Heating, and Brewing Overfilling watert ank even when power is off. Fill valve not sealing properly . Fill valve installed backwards. W ater entering t ank continuously , usually slowly . Disassemble valve and clean out dirt.
Page 9 T roubleshooting: Filling, Heating, and Brewing (con’t.) T ank does not heat. Thermostat faulty or out of calibration. Heater faulty . Make sure thermostat is turned on. Check resistance across elements with wires disconnected. Recalibrate thermostat.
Page 10 T roubleshooting: Filling, Heating, and Brewing (con’t.) Brewing Problems The brewing system consists of the following component s: • St art and Stop switches , located on the front control panel. • Brew Timer , located in the top control section under the top cover .
Page 1 1 P200/RAPS200 Brewers Exploded V iew for the P200-E ITEM DESCRIPTION P ART #.
Page 12 P200/RAPS200 Brewers Exploded V iew for the P200 (G version only) ITEM DESCRIPTION P ART #.
Page 13 P200/RAPS200 Brewers Exploded V iew for the RAPS200-E ITEM DESCRIPTION P ART #.
Page 14 P200/RAPS200 Brewers Exploded V iew for the RAPS200 (G version only) ITEM DESCRIPTION P ART #.
Page 15 P200/RAPS200 Brewers Rough-In Drawing for the P200-E.
Page 16 P200/RAPS200 Brewers Rough-In Drawing for the RAPS200-E.
Page 17 P200/RAPS200 Brewers Wiring Diagram for P200-E/RAPS200-E.
.
W ARRANTY for P200/RAPS200 Series GENERAL W ARRANTY INFORMA TION Grindmaster maintains the highest st andard of quality control in the manufacturing of American Metal W are products. W e use the finest component s and materials, and employ quality engineering standards and tests.
Ein wichtiger Punkt beim Kauf des Geräts Grindmaster P200E (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Grindmaster P200E noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Grindmaster P200E - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Grindmaster P200E reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Grindmaster P200E erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Grindmaster P200E besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Grindmaster P200E verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Grindmaster P200E. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Grindmaster P200E gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.