Benutzeranleitung / Produktwartung 765000 des Produzenten Graham Field
Zur Seite of 24
765000 AL TERNA TING PRESSURE MA TTRESS SYSTEM WITH ACTIVE SENSOR TECHNOL OGY USER MANUAL Impor tant: Do not operate the Mattress System without rst reading and understanding this manual! Save this manual for future use. Info: The most current version of this manual can be found online at www.
2 765000-INS-LAB-RevC11 CONTENTS INTRODUCTION..................................................................................... 3 INTENDEDUSEOFTHISDEVICE ........................................................ 3 CONTRAINDICA TION .
765000-INS-LAB-RevC11 3 INTRODUCTION Use this manual for set-up and operation of the Lumex ® AltaDyne ® Sensor Plus 765000 Alternating Pr essur e Mattr ess System with Active Sensor T echnology . Read all instructions befor e using the mattr ess system.
4 765000-INS-LAB-RevC11 IMPORT ANT SAFETY PRECA UTIONS The safety statements pr esented in this chapter r efer to the basic safety information that should be obser ved by those using this Mattr ess System.
765000-INS-LAB-RevC11 5 WARNING T o reduce the risk of bur ns, electrocution, r e, or per sonal injur y: W ARNING:Donotleavethisproductunattendedwhen pluggedin.
6 765000-INS-LAB-RevC11 W ARNING:Patiententrapmentwithbedsiderails maycauseinjuryordeath.Thebedframeandits components,includingthemat.
765000-INS-LAB-RevC11 7 EQUIPMENT SYMBOLS Manufacturer “BF”symbol: Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment Functi.
8 765000-INS-LAB-RevC11 PRODUCT DESCRIPTION PUMP AND MA TTRESS SY STEM pumpandmattresssystem CPRvalves quickconnectors (mattress-pump connectors) mattress footend symbol pump PUMP.
765000-INS-LAB-RevC11 9 PUMP: FRONT P ANEL Fr ont panel of pump is shown below . Descriptions of buttons and indicators follow . T uningbutton; indicatorsatleftofbutton Powerfailu.
10 765000-INS-LAB-RevC11 Tuning button: The tuning button ne-tunes the mattr ess system's auto-adjusted pr essur e. Thr ee tuning settings ar e available: 0 System auto-adjusted pr essur e .
765000-INS-LAB-RevC11 11 Maxfir m button: The pump will automatically enter maxrm mode ever y time the power is turned on. Maxrm mode ensur es the pump is able to r each its maximum operating pr essur e. Maxrm mode will last for 20 minutes, and then the system will automatically enter auto-adjust mode.
12 765000-INS-LAB-RevC11 Low pr essur e indicator: The low pressur e indicator (yellow LED) illuminates, and the alarm sounds, when an abnormally low pr essur e level occurs. If the low pr essur e indicator persistently illuminates inappr opriately: 1.
765000-INS-LAB-RevC11 13 INST ALLA TION UNP ACKING 1. Car efully r emove all components fr om the carton. 2. Inspect all components. 3. If damage is evident to the contents, please notify the carrier and your Graham-Field equipment pr ovider . PUMP AND MA TTRESS SETUP 1.
14 765000-INS-LAB-RevC11 W ARNING:Locateallcordssothattheywillnotbe steppedon,trippedover ,orotherwisesubjectedto damageorstress. W ARNING: Donotuseahouseholdextensioncordifthe electricalcorddoesnotreachthepoweroutlet.
765000-INS-LAB-RevC11 15 OPERA TION GETTING ST AR TED 1. T urn the main power switch to the ON position. 2. Pr ess the fr ont panel power button. The power indicator will illuminate.
16 765000-INS-LAB-RevC11 TRANSPORT CAP In case of power failur e or transport: Disconnect the quick connector and cap the mattr ess with the transport cap to slow deation. Info: This system is equipped with cell-on-cell technology to provide added support and prevent bottoming out in the event of a power failure.
765000-INS-LAB-RevC11 17 MAINTENANCE CLEANING W ARNING: To reducetheriskofincreasedbacterial growth,infection,illness,orinjuryfromcontamination, tho.
18 765000-INS-LAB-RevC11 Fuse replacement tool needed: small screwdriver 1. If you suspect a blown fuse, disconnect the plug fr om the wall outlet immediately . 2. Use a small scr ewdriver to r emove the cover of the fuse holder (fuse locations ar e shown in pictur e at right).
765000-INS-LAB-RevC11 19 SPECIFICA TIONS Pump Specication Power Supply (Info: see rating label on product) AC 120V 60 Hz 0.17A (for 120V system) Fuse Rating T1A, 250V Cycle time Fixed / 10 minutes Dimensions (L x W x H) 1 1.4" x 7.9" x 4.
20 765000-INS-LAB-RevC11 LIMITED WARRANTY GF Health Pr oducts, Inc. warrants the Lumex ® AltaDyne ® Sensor Plus 765000 Alternating Pr essur e Mattr ess System with Active Sensor T echnology for a period of twelve months for defects in workmanship and materials.
765000-INS-LAB-RevC11 21 APPENDIX A: EMC INFORMA TION Guidance and Manufacturer’s De claration- Electromagnetic Emissions: This device is intended for use in the electromagnetic environment specified below . The user of this device should make sure i t is used in such an environmen t.
22 765000-INS-LAB-RevC11 Guidance and Manufact urer ’ s Declaration- Electromagn etic Immunity: This device is intended for use in the electromagnetic environment spec ified bel ow . T he user of t his device should ma ke sure it is us ed in such an environment.
765000-INS-LAB-RevC11 23 a The ISM (indu str ial, sc ient ific and medical) bands between 150 kHz and 80 MHz are 6,765 MHz to 6,795 MHz;13,553 MHz to 13,567 MHz; 26,957 MHz to 27,283 MHz; and 40,66 M Hz to 40,70 MHz.
USA Corporate Headquar ters: GF Health Products, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 telephone: 770-368-4700 fax: 770-368-2386 www .grahamfield.
Ein wichtiger Punkt beim Kauf des Geräts Graham Field 765000 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graham Field 765000 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graham Field 765000 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graham Field 765000 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graham Field 765000 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graham Field 765000 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graham Field 765000 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graham Field 765000. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graham Field 765000 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.