Benutzeranleitung / Produktwartung Series A des Produzenten Graco
Zur Seite of 16
3A2799A EN Instructions - Parts XHF Spray Gun For spraying viscous materials at high flow rates. For professional use only. Part No. 262854, Series A Includes an XHD ™ RAC ® Guard and XHD429 SwitchTip ™ 7250 psi (50 MPa, 500 bar) Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual.
2 3A2799A Contents W a r n i n g s ................................. 3 Operation ................................. 5 System Requirements ..................... 5 Ground the System ....................... 5 Gun Trigger Lock ........................ 5 Pressure Relief Procedure .
Warnings 3A2799A 3 Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks.
Warnings 4 3A2799A EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system com- ponent.
Operation 3A2799A 5 Operation Keep the wallet-sized warning card provided with this gun with the operator at all times. The card contains important treatment information should an injection injury occur. Additional cards (part no. 222385) are available at no charge from Graco.
Operation 6 3A2799A Operation 1. Connect a fluid hose (A) to the gun inlet. Use high pressure swivel 207946 if desired (order sepa- rately). See Fig. 2. 2. With SwitchTip (8) and tip guard (9) removed, start the pump. Flush the pump according to the instruc- tions supplied with it.
Operation 3A2799A 7 Gun Care Cleaning during the day 1. Relieve pressure, page 5. 2. Use a solvent-soaked brush to clean the spray tip. Clean the front of the tip frequently during the day to help reduce buildup. 3. Clean the tip and tip guard at the end of each work day.
Operation 8 3A2799A Flush the Gun NOTE: This procedure requires a grounded pail of com- patible flushing fluid. 1. Relieve pressure. 2. Remove the tip guard and spray tip. Soak and clean the parts. 3. Single component systems only: Remove the pump intake from the original pail.
Service 3A2799A 9 Service Disassembly for Repair or Cleaning NOTE: If replacing only the needle and seat, step 4 and 5 are not required. However, removing them allows you to clean the gun more thoroughly. 1. Relieve pressure. 2. Disconnect the fluid hose (A) and swivel (if used).
Service 10 3A2799A 5. Loosen the setscrew (15) then remove the fluid housing (22) from the gun body (1). See F IG .8 . 6. While supporting the spring guide (16) to prevent bending the needle (2c), loosen the setscrews (17) then remove the spring guide (16).
Service 3A2799A 11 3. Place the gasket (2b) on the valve seat (2a). Grease the threads of the valve seat (2a) then install into the fluid housing (22). Torque to 20-25 ft-lb (27-34 N•m). See F IG .1 3 . 4. Install the spring guide (16) and seat it against the needle.
Service 12 3A2799A 7. Position the trigger (24) on the gun body. Insert the pivot pin (23) into the top hole (A) and secure with the screw (13) on the other side.
Parts 3A2799A 13 Parts --- Not for sale. ▲ Replacement Danger and Warning labels, tags and cards are available at no cost. 9 8 2a 2b 2c 22 2e 2d 17 17 18 26 26 19 20 15 13 21 23 1 24 16 ti19282a 1 Must install as shown with the notch on the bottom.
Parts 14 3A2799A Needle and Seat Kits The needle and seat are available only in kits that include items 2a through 2e. The standard non-diffused needle and seat kit, 237260, includes all OEM parts and has the number 125 stamped on the needle and seat.
Technical Data 3A2799A 15 Technical Data * Sound pressure measured 3.3 feet (1 meter) from equipment. ** Sound power measured per ISO-9614-2. Maximum Working Pressure ..................... 7250 psi (50 MPa, 500 bar) Fluid orifice size ................
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. )RUSDWHQWLQIRUPDWLRQVHHZZZJUDFRFRPSDWHQWV 2ULJLQDOLQVWUXFWLRQV This manual contains English.
Ein wichtiger Punkt beim Kauf des Geräts Graco Series A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco Series A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco Series A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco Series A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco Series A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco Series A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco Series A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco Series A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco Series A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.