Benutzeranleitung / Produktwartung 240379 des Produzenten Graco Inc.
Zur Seite of 22
308846 Re v . D First choice when quality counts. t 8115A This gun and hose for Delta Spray Air Spray packages and Delta Spray HVLP packages This gun and hose for PRO 3500sc Electrostatic packages INSTRUCTIONS–P ARTS LIST INSTRUCTIONS This manual contains important warnings and information.
1A 308846 Instruction Manual – Parts List Changes This page contains a summary of changes or additions that do not appear in the contents of the manual. Improve pressure control instructions (Graco ref. V6557). Change 30psi HVLP fluid regulator and gauge to 60psi (Graco ref.
1B 308846 Notes.
2 308846 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 308846 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury . D This equipment is for professional use only . D Read all the instruction manuals, tags, and labels before operating the equipment.
4 308846 Setup CAUTION This equipment is compatible with most water-based materials. See the wetted parts in the T echnical Data section and your fluid and solvent manufacturer ’s compatibility information. Do not use acid catalyzed materials; they are incom- patible with the acetal used in this pump.
5 308846 Setup Hose Connections This package is shipped with the hoses connected. Before you disconnect any hoses, make a note of the proper connections. Flush Pump Before First Use The pump was tested in water . If the test solution could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent.
6 308846 Operation Using the Gun See the gun instruction manual for gun operation, care, flushing, cleaning, and technical data. Read the entire gun manual before operating the sprayer . Pressure Relief Procedure See Fig. 1 The system remains pressurized until pressure is manually relieved.
7 308846 Operation Priming the System See Fig. 1 1. Close the gun air regulator (F). 2. If your system has a fluid pressure regulator (G), close it. 3. Open the recirculating valve (J). 4. Open the bleed-type master air valve (K). 5. Slowly set the pump air regulator (E) pressure to 20 to 30 psi (140 to 210 kPa, 1.
8 308846 Operation Using the Recirculation Feature See Fig. 1 The recirculation tube drains unused fluid back into the fluid container , ensuring an even flow at the gun. Recirculation also provides gentle fluid agitation. T o recirculate fluid, open the recirculation valve (J) while you are spraying.
9 308846 Maintenance See the separate component instruction manuals for individual component maintenance procedures. Access to some system components requires that you remove the shields. The following steps are for shield removal. Shield replacement is the reverse of these steps, so make sure you take notes on the proper hose connections.
10 308846 Parts List Stand-Mount Packages with Fluid Pressure Regulators Model No. 240367 , Delta Spray air spray package Model No. 240368 , Delta Spray HVLP package Model No. 240369 , PRO 3500sc electrostatic package Model No. 240370 , PRO 4500sc electrostatic package Model No.
11 308846 Parts Drawing 23 Grounding Detail 8047A 10 13 26 37 17 5 1 9 12 6 7 4 4 8 16 16 18 18 19 24 25 27 28 31 30 38 222300 shown 39 40 17 34 21 22 32 33 32 29 41 42 43 44 45 46 47 44 22, 23 Stand-Mount Packages with Fluid Pressure Regulators Model No.
12 308846 Parts List Stand-Mount Packages with Surge T anks Model No. 240379 , Delta Spray air spray package Model No. 240380 , Delta Spray HVLP package Model No. 240381 , no hoses or gun Ref. No. Part No. Description Qty . 1 240210 SHIELD ASSY , front Contains 1a to 1h, shown in Fig.
13 308846 Parts Drawing Grounding Detail 8048A 10 13 26 37 23 17 5 1 9 12 7 4 8 16 16 18 19 24 25 17 34 21 22 32 33 32 29 41 42 43 44 45 39 4 44 22, 23 3 27 28 30 31 40 32 Stand-Mount Packages with Surge T anks Model No. 240379 , Delta Spray air spray package Model No.
14 308846 Accessory Fluid Filter Kit Fluid Filter Kit 240440 Ref. No. Part No. Description Qty . 101 1 14361 FIL TER, fluid 1 102 1 13322 CONNECTOR, male 1 103 054188 TUBE; PTFE; R 3/8” O.
15 308846 Accessory Suction T ube Kit Suction T ube Kit 240465 Ref. No. Part No. Description Qty . 201 232692 KIT ASSEMBL Y , suction tube 1 202 19341 1 NIPPLE 1 203 193459 TUBE, recirculation 1 204 103473 TIE, wire 5 The Suction Kit, listed above, can be installed for drawing fluid from a container that is not directly under the unit.
16 308846 T echnical Data Category Data Maximum fluid working pressure 100 psi (0.7 MPa, 7 bar) Maximum incoming air pressure 100 psi (0.7 MPa, 7 bar) Maximum operating temperature 120 _ F (49 _ C) Gun See separate gun instruction manual. Pump See separate pump instruction manual.
17 308846 Dimensions 8171A 34.0 in. (864 mm) 17.5 in. (445 mm) 16.5 in. (419 mm).
18 308846 Notes.
19 308846 Notes.
20 308846 Manual Change Summary This manual went from Rev . A to Rev . B to make the following changes: D Model No. 240371 (regulated packages with no hoses or gun) and Model No. 240381 (surge tank packages with no hoses or gun) are added. See the front cover and the Parts Lists on pages 10 and 12.
Ein wichtiger Punkt beim Kauf des Geräts Graco Inc. 240379 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco Inc. 240379 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco Inc. 240379 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco Inc. 240379 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco Inc. 240379 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco Inc. 240379 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco Inc. 240379 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco Inc. 240379. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco Inc. 240379 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.