308–367 Rev . B Supersedes Rev . A and PCN B First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 23:1 RA TIO Monark Sprayers 2760 psi (19.
308–367 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembling the Sprayer 4 . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . .
3 308–367 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury . This equipment is for professional use only . Read all the instruction manuals, tags, and labels before operating the equipment.
4 308–367 Assembling the Sprayer Cart Mounted Pump Assemble the suction hose (6) to the elbow (5) at the pump intake. Screw the suction tube (7) onto the other end of the hose. See Fig. 1. Fig. 1 03356 7 6 5 W all Mount Pump 1. Screw the gauges (25) into the air regulators (F , G).
5 308–367 Installation Be sure that all operators read and understand this entire manual and the separate manuals supplied with components and accessories before using this equip - ment. Reference numbers and letters in parentheses refer to the figures and parts drawings.
6 308–367 Installation Fig. 4 KEY A Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Master Air V alve (for accessories) E Air Line Filter F Pump Air Regu.
7 308–367 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in - jected through the skin and cause serious injury .
8 308–367 Operation Starting and Adjusting the Pump W ARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. See Fig. 5. Be sure the air regulators (F , G) and bleed- type master air valve (B) are closed.
9 308–367 Operation 03140 Fig. 5 W all Mount Pumps Cart Mounted Pumps Pail Mounted Pumps 40 46 03142 G F H B 18 J 1 26 G B H 7 F G F H 36 03145A.
10 308–367 Parts See Detail. NOTE: Apply thread sealant to all male threads, except at swivel connections. 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 15 (Ref) 16 17 18 19 19 23 24 25 26 28 29 30 31 32 37 47 A A 37 (Ref) 10 Part No.
11 308–367 Parts Part No. 236–721 Cart Mounted Pump Ref No. Part No. Description Qty . 1 100–016 LOCKW ASHER, spring; 1/4” 2 2 100–022 CAPSCREW , hex hd; 1/4–20 x 3/4” (19 mm) long 2 3 1.
12 308–367 Parts 28 23 52 18 24 29 22 51 20 15 16 17 19 18 17 (Ref) B B 31 32 31 10 9 26 39 43 40 41 42 44 45 46 35 36 29 18 13 7 6 25 5 (Ref) 12 34 33 31 32 31 29 50 49 3 4 5 49 7 6 25 49 14 NOTE: Apply thread sealant to all male threads, except at swivel connections.
13 308–367 Parts Part No. 236–722 Pail Mounted Pump Ref No. Part No. Description Qty . 3 171–987 TEE; 3/8 npt(f) x 1/4 npt(f) run; 3/8 npt(f) branch 1 4 156–823 UNION, swivel; 1/4 npt(m) x 1/4 npt(f) 1 5 202–812 HOSE, air; neoprene; 1/4” (6 mm) ID; cpld 1/4 npt(mbe); 1.
14 308–367 Parts Part No. 236–723 W all Mount Pump See Detail. Included with wall bracket (7). B A 5 22 23 (Ref) 7 23 13 3 1 4 9 18 26 11 10 12 3 (Ref) 16 28 15 32 17 17 14 25 7 (Ref) 29 31 32 19 30 34 36 20 21 24 NOTE: Apply thread sealant to all male threads, except at swivel connections.
15 308–367 Parts Part No. 236–723 W all Mounted Pump Ref No. Part No. Description Qty . 1 159–101 HOUSING, suction tube intake 1 3 214–961 HOSE, suction, fluid; nylon 3/4 npt(mbe); 3/4” (19 mm) ID; 6 ft (1.
16 308–367 The Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
Ein wichtiger Punkt beim Kauf des Geräts Graco Inc. 236722 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco Inc. 236722 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco Inc. 236722 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco Inc. 236722 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco Inc. 236722 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco Inc. 236722 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco Inc. 236722 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco Inc. 236722. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco Inc. 236722 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.