Benutzeranleitung / Produktwartung 236-900 des Produzenten Graco Inc.
Zur Seite of 16
308–332 Rev . D Supersedes Rev . C and PCN D First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. ST AINLESS STEEL, 15:1 RA TIO Monark Sprayers 2700 psi (18.
T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . .
INJECTION HAZARD Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed into the eyes or onto the skin can also cause serious injury .
4 308-332 FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 308-332 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 4.
6 308-332 Installation Be sure that all operators read and understand this entire manual and the separate manuals supplied with components and accessories before using this equip - ment. Reference numbers and letters in parentheses refer to the figures and the parts lists on pages 10–13.
7 308-332 Installation Fig. 3 KEY A Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Master Air V alve (for accessories) E Air Line Filter F Pump Air Regulator G Gun Air Re.
Operation Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in - jected through the skin and cause serious injury .
Fig. 4 W all Mount Pumps (Model 236–065) 16 21 34 6 10a 10b 29 Pail Mount Pumps (Model 236–069) 10a 29 10b 6 16 40 1 42 Operation Slowly open the pump air regulator (10b) until the pump starts. Run the pump slowly until fluid comes from the drain valve (6).
10 308-332 Parts Part No. 236–065 W all Mount Pump with Fluid Regulator Includes items 1–50 Part No. 236–898 W all Mount Pump without Fluid Regulator Includes items 1–28, 43–50 02802A 1 See Detail at left.
11 308-332 Parts Part No. 236–065 W all Mount Pump with Fluid Regulator Includes items 1–50 Part No. 236–898 W all Mount Pump without Fluid Regulator Includes items 1–28, 43–50 Ref. No. Part No. Description Qty . Ref. No. Part No. Description Qty .
12 308-332 Parts Part No. 236–069 Pail Mounted Pump with Fluid Regulator Includes items 1–50 Part No. 236–900 Pail Mounted Pump without Fluid Regulator Includes items 1–28, 33, 40–50 2 8 9 Apply thread sealant to male threads, except at swivel connections.
13 308-332 Parts Part No. 236–069 Pail Mounted Pump with Fluid Regulator Includes items 1–50 Part No. 236–900 Pail Mounted Pump without Fluid Regulator Includes items 1–28, 33, 40–50 Ref. No. Part No. Description Qty . Ref. No. Part No. Description Qty .
14 308-332 Notes.
15 308-332 T echnical Data Category Data Maximum working pressure 2700 psi (18.5 MPa, 185 bar) Maximum incoming air pressure 180 psi (1.25 MPa, 125 bar) Ratio 15”1 W etted parts: Pump See manual 308.
16 308-332 Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
Ein wichtiger Punkt beim Kauf des Geräts Graco Inc. 236-900 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco Inc. 236-900 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco Inc. 236-900 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco Inc. 236-900 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco Inc. 236-900 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco Inc. 236-900 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco Inc. 236-900 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco Inc. 236-900. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco Inc. 236-900 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.