Benutzeranleitung / Produktwartung 313255K des Produzenten Graco
Zur Seite of 34
Instr uctions-P ar ts Merkur ® Heated Spra y P ac ka g es 313255K EN For finishing and coating appli cations requiring heated ma terials, in hazardous or non-hazardous locations. For pr ofessional use onl y . See pages 5 to 7 f or model inf ormation, including maxi- mum w orking pressures and appro v als.
Related Manua ls 2 313255K Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings 313255K 3 Wa r n i n g s The f ollowing w arnings are fo r the setup , use , grounding, maint enance, and rep air of this equipment. The e xclama- tion point symbol ale r ts you to a gener al warning and the hazar d symbol ref ers to proc edure-specific risk.
Warnings 4 313255K EQUIPMENT MISUSE HAZARD Misuse can ca use death or serious injury . • Do not oper ate the unit when f atigue d or under the influence of drugs or alcohol. • Do not exceed the maximum w orkin g pressure or temperature rating of the lowest rated system component.
Models 313255K 5 Models Chec k the identification plat e (ID) f or the 6-digit part number of y our pac kage. Use the f ollowing matrix and tab les to define the compon ents of yo ur pack age.
Models 6 313255K Merkur 28:1 Heated P ac ka ges (G28Wxx and G28Cxx) Maximum Inlet Air Pressure: 100 psi ( 0.7 MPa, 7 bar) Maximum Fluid W orking Pressure: 2800 psi (19.3 MP a, 193 bar) Merkur 30:1 Heated P ac ka ges (G30Wxx and G30Cxx) Maximum Inlet Air Pressure: 100 psi ( 0.
Models 313255K 7 Merkur 48:1 Heated P ac ka ges (G48Wxx) Maximum Inlet Air Pressure: 100 psi (0 .7 MP a, 7 bar) Maximum Fluid W orking Pressure: 4800 psi (33.
Installation 8 313255K Installation Key: A Air Shutoff V alve (optional accessor y) B Air Filter (optional accessor y) C Air Line Moisture T rap and Drain V alve (optional accessor y) D Fluid Heater E.
Installation 313255K 9 General Inf ormation F IG . 1 is only a guide f or selecting and installing system components and accessories . Contact you r Graco dis- tributor f or a ssistance in designing a system to suit your par ticula r needs.
Installation 10 313255K Supplied Components See F IG . 1. Components vary b y pac kage ordere d. See tab les on pages 6 to 7. Y our package ma y include: • The red-h andled bleed-type master air valve (U) is required in your syste m to reliev e air trapped between it and the air moto r and gun when the v a lve is closed.
Installation 313255K 11 Gr ounding The equipment m ust be ground ed. Grounding reduce s the risk of static and electric shock b y provid ing an escape wire f or the electrical curren t due to static b uild up or in the e v ent of a sh or t circuit. 1.
Installation 12 313255K Electrical Housing Access Tilt the heater a wa y from the pump f or easier access to the scre ws on the cov e r of the electrical housing. Hose Connections See F IG . 1, page 8. 1. Attach one end of the air hose t o the gun air regula- tor (T , G40 spra y guns only).
Operation 313255K 13 Operation Pressure Relief Pr ocedure 1. Enga ge the tr igger lock. 2. See F IG . 1. T ur n off the b leed-type ma ster air v alv e (U). 3. Disengage the trigger loc k. 4. Hold a metal par t of the gun firmly to a grounded metal wast e container .
Operation 14 313255K We t C u p Bef ore star ting, fill wet cup 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solv ent. Prime the Pump 1. See F IG . 1. Lock gun trigger. Remo ve tip guard and spra y tip from gu n (H). Refer to gun manual.
Operation 313255K 15 Adjust the Atomization 1. Do not turn on atomizing air supply . Fluid pressure is controlled b y the air pressur e supplied to the pump (pump a ir regulator) .
Operation 16 313255K 3. See F IG . 7. For narrower patter n, tu r n patter n adjustment v alv e knob (AA) countercloc kwise (out). If pattern is still not nar row enough, increase air pressure to gun slightly or use different size tip . Shutdown F ollow Pressure Re lief Pr ocedure , p age 13.
Maintenance 313255K 17 Maintenance Preventive Maintenance Schedule The oper ating conditio ns of y our particular system determine how often maintenance is req uired. Estab lish a prev entive maintenance sched ule by recording when and what kind of maintena nce is needed, and then deter mine a regular schedule f or checking y our system.
Troubleshooting 18 313255K T roub leshooting NO TE: Check all possible prob lems and causes before disassemb ling the pump . F * T o deter mine if the fluid hose or gun is obstructed, relie v e the pressure. Disconnect the fluid hose and place a con- tainer at the p ump fluid outlet to catch an y fluid.
DataTrak Controls and Indicators 313255K 19 DataT rak Contro ls and Indicators Key for F IG . 8 AA Runaw a y Limit, in cycles per min ute (user settable; 00=OFF) AB Lower Displacement (user settab le).
DataTrak Operation 20 313255K DataT rak Operation NO TE: The displa y (AE) will tur n off after 1 minute to sav e batter y life . Press any ke y to wake up the display . Setup Mode 1. See F IG . 8. Press and hold f or 5 seconds until Setup menu appears .
DataTrak Operation 313255K 21 Prime/Flush 1. See F IG . 8. T o enter Prime/Flush mode , press an y ke y to wake up the display , th en press . The Prime/Flush symbol will app ear in the displa y and the LED will flash . 2. While in Prime/Flush mode, runaw a y protect ion is disabled and the batch to taliz er (BT) will not count.
DataTrak Operation 22 313255K T able 1:Dia gnostic Codes Symbol Code Code Name Diagnosis Cause Runawa y (DataT rak only) Pump running faster than set runawa y limit. • I ncreased air pressure. • Increased fluid output. • Exhausted fluid supply .
DataTrak Operation 313255K 23 Replace DataT rak Battery or Fuse Replace Battery 1. Unscrew cab le from the bac k of the reed s witch assembly . See F IG . 10 . 2. Re mov e the cable from the two cable clips. 3. Re mov e DataT rak modu le from brack et.
Parts 24 313255K Pa r t s NO TE: P ar ts v ar y by model. See P ar ts Lists on pages 26 to 28. 64 67 67 63 62 66 84 64 1 60 61 75 69 70 71 72 4 5 83a 83b 6 74 73 81 82 77 2 3a 3b ti13018a (wall mount .
Parts 313255K 25 65 9 22 10 8 G40 Gun Shown t15484b ti13143a ti13114a 16 16 Non-Hazardous Loca tion Electrical Cord Parts (120V Cart Mount Only) 79 80 49 53 68 ti13261a 60 78 (120V only) 51.
Parts 26 313255K G28xxx Models ----- Not sold separately . NO TE: Replacement W arni ng labels, signs, tags, and cards are av ailable at no cost. Ref. No.
Parts 313255K 27 G30xxx Models ----- Not sold separately . NO TE: Replacement W arni ng labels, signs, tags, and cards are av ailable at no cost. Ref. No.
Parts 28 313255K G48Wxx Models ----- Not sold separately . NO TE: Replacement W arni ng labels, signs, tags, and cards are av ailable at no cost. Ref. No.
Kits 313255K 29 Kits W all Mount Kit 24A578 NO TE: Air Controls Mount ing Kit 24E883 (P art 49, see page 26, 27, or 28) also is requir ed f or wall mounting a pac kage that has a co ntrol panel. Heated Car t Mount Kit 256427 102 101 ti12633a Ref No. Description Qty .
Kits 30 313255K Pump and Gun Contr ol P anel Kit Kit 24A581 301 302 303 304 305 306 307 308 312 314 317 309 308 304 310 316 ti13565a 311 307 313 319 321 303 ti13467a 315 Ref. P art Description Qty . 301 114362 V AL VE, ball 1 302 15T643 SWIVEL, tee , 3/8 npt(m) x 1/2T 1 303 ----- TUBE, 1/2 OD , cut to fit, order T ubing Kit 24D496 1.
Kits 313255K 31 Pump Onl y Contr ol P anel Kit Kit 24A583 301 303 314 317 326 311 305 304 310 313 306 307 308 304 ti13567a Ref. P art Description Qty .
Kits 32 313255K DataT rak NO TE: See DataT rak man ual, 313541, f or all DataT rak related part numbers and kit inf ormation, including the reed s witch and solenoid. PTFE Suction Hose Kits For pumping aci d materials tha t are compatible with PTFE. Incl udes suction hose, swivel, and stra iner .
Wall Bracket Mounting Dimensions 313255K 33 W all Brac ket Mounting Dimensions Te c h n i c a l D a t a Maximum fluid working pres sure . . . . . . . . . . . . . . . See Models tab le on page 5. Maximum pump air inlet pressure . . . . . . . . . . . . .
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructions. Thi s manual contains Eng lish.
Ein wichtiger Punkt beim Kauf des Geräts Graco 313255K (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco 313255K noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco 313255K - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco 313255K reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco 313255K erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco 313255K besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco 313255K verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco 313255K. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco 313255K gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.