Instr uctions - P ar ts A utomatic Plural Component, Imping ement Mix Spra y Gun For use with non-flammab le foam and pol yurea. Not f o r use in e x plosive atmospheres. 3500 psi (24.2 MP a, 242 bar) Maxim um Fluid Working Pressure 80-130 psi (0.55-0.
Contents 2 310649C Contents Manual Con v entions . . . . . . . . . . . . . . . . . . . . . . . . 2 Air Purge Guns . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Round Pattern Gu ns . . . . . . . . . . . . . . . . . . . . . . 3 Flat P atte rn Guns .
Air Purge Guns 310649C 3 Air Pur g e Guns Round P attern Guns Flat P attern Guns Related Manuals F or complete saf ety , operat ion, and repair inf or mat ion, ref er to the applicab le man ual listed below . Mix Chamber Gun P ar t No., Series P ar t No.
Mechanical Purge Guns 4 310649C Mec h anical Pur g e Guns Standar d Round P attern Guns Direct Impingement Round P attern Guns Direct Impingement Flat P attern Guns Related Manuals F or complete safety , operation, a nd repair informatio n, refer to the applicable manual listed be low .
Warning 310649C 5 W ARNING SKIN INJECTION HAZ ARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce ski n. This may look lik e just a cut, but it is a serious injur y that can resu lt in amputation. Get immediate surgical treatmen t.
Isocyanate Hazard Kee p A and B Components Sep arate 6 310649C Isoc y anate Hazar d K eep A and B Components Separate BURN HAZARD Equipment surf aces and fluid that’ s heated can become v er y hot during operation. T o av oid se vere burns, do not to uch hot fluid or equipm ent.
Grounding 310649C 7 Gr ounding Chec k your local electrical code and pr opor tioner man- ual f or detailed grounding instructions. Ground the sp ray gun through connection to a Graco-appro ved grounded fluid supply hose. Piston Safe ty Loc k Engage piston sa fety lock whene ver y ou stop spray- ing, to av oid accidental triggering.
Overall Vi ew 8 310649C Overall Vie w Key: A A Side Fluid V a lve (ISO) B B Side Fluid V a lve (RESIN) CA i r C a p D Fluid Housing E Gun Fluid Manifold F Cleanoff Air V alve G Piston Safety Loc k H C.
Installation 310649C 9 Installation Mounting gun to r od Mounting gun to stationary suppor t or robot arm 1. T o mount the gun o n a 1/2 in. diameter rod, inser t the bar (A) thr ough the hole in the gun body as shown. 2. Secure the gun to the bar b y tightening 1/4 in.
Installation 10 310649C Connecting airline and accessories 1. On each gun air su pply line, install an air pressu re regulator . • It is recommende d that the tip clean off air , gun actuation, and gun deactuation air be supplied and regulated separ ately .
Setup 310649C 11 Setup 1. Close fluid v alves A and B . 2. Connect A (ISO) and B (RESIN) fluid hose s to fluid manif old. 3. Engage pist on safety loc k .
Setup 12 310649C 7. Actuate gun to chec k fo r full mix chamber trav el. F ront of air cap (C) sh ould be approximat ely flush with front retainin g r ing (U). 8. Open cleanoff air valv e (K) 1/4-1/2 tur n and actuate air line to check that clean off air is flowing.
Pressure Relief Procedure 310649C 13 Pressure Relief Pr ocedure Read wa r nings, page 5. Relie ve pressure bef ore cleaning or repairing gun. 1. Engage pist on safety loc k . CA UTION Air supply is required f or gun actuation. Do not dis- connect gun air suppl y until fluid pressure is relie ved.
Shutdown 14 310649C Shutdo wn F or complete shutdown proce dure, ref er to Fusion Gun manual 309550 or 309856..
Shutdown 310649C 15.
Parts 16 310649C Pa r t s Air Pur g e Gun 24 15 ‡ 8 7 ‡ 27 ‡ 19 1 ‡ 25 ‡ 9 ‡ 10 23 ‡ * ‡ 11 3 ‡ ‡ 26e ‡ 26c ‡ 26d 12c 12f 12e 12b 12d TI4521b 50 ‡ 37 TI2557A Flat Pattern Detail Round Pattern Gun Shown 19 10 39 40 † * 3 T orque to 235-24 5 in-lb (26.
Parts 310649C 17 * These par ts are only av a ilable in repair kits. T o select a kit, ref er manual 3095 50. † These par ts are not av ailable singly . ‡ These par ts are included in F ront End Replacemen t Kit 246361. These par ts are included in Safety St op Assembly 248064 (include s 1 of item 24).
Parts 18 310649C Mechanical Pur ge Gun TI4523b 92 8 46* †‡ 25 39 19 32 16* 8 31 14* 15 10 17 59 3 18 1 35 ‡ 11 ‡ 23 ‡ 46* †‡ 21* ‡ 20 ‡ 44 ‡ *24 †‡ 7 † 12a 12b 12d 12g 50 12c 12e 12f 34 40 T orque to 125-135 in-lb (14-15 N•m).
Parts 310649C 19 * These par ts are only av a ilable in repair kits. T o select a kit, ref er to Gun Repair Kits in man ual 309856. † These par ts are not av ailable singly . ‡ These par ts are included in Fluid Housing Asse mbly Kit 248004 (i ncludes 1 of items 24 and 46).
Mounting Dimensions 20 310649C Mounting Dimensions Gun mounting plate dimensions in. (mm) F IG . 1 ti4751b 1.30 (33.0) 0.625 (15.88) 0.625 (15.88) 1 (25.
Technical Data 310649C 21 T ec hnical Data All brand names or mar ks are used f or identification purposes and are trademarks of Gra co Inc. or their respectiv e own er s. Accessories Category Data Maximum Fluid W orking Pressure 3500 psi (24.2 MP a, 242 bar) Minimum Air Inle t Pressure 80 psi (0.
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructions. This manual contains English.
Ein wichtiger Punkt beim Kauf des Geräts Graco 310649C (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco 310649C noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco 310649C - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco 310649C reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco 310649C erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco 310649C besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco 310649C verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco 310649C. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco 310649C gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.