Benutzeranleitung / Produktwartung 309935d des Produzenten Graco
Zur Seite of 28
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2003, Graco Inc. is r egistered to I. S. EN ISO 9001 309935D Operation / Fonctionnement / Funcionamiento Electric Air less Spra y ers Pulvér isateurs électriques type Air less Pulv erizadores eléctr icos sin aire 3300 psi (227 bar , 22.
Warnings 2 309935D Wa r n i n g s The f ollowing ar e general w ar nings related to the se tup , use, g rounding, mainten ance and repair of this equip ment. Additional, mo re sepcific warnings ma y be fo und through out the body of this manual wher e applicable .
WARNING 309935D 3 WA R N I N G EQUIPMENT MISUSE HAZARD Misuse can ca use death or serious injury . • Do not exceed the maximum workin g pressure or temperature rating of the lo west rated system component. Re ad T echnical Data in all equipment man uals.
Mise en garde 4 309935D Mise en gar de Les mises en gardes suivantes sont des mi ses en garde de sécurité relatives à la configuration, utilis ation, mise à la terre, maintenance e t réparation de ce matériel. D’aut res mises en garde pl us spécifiques figurent da ns ce manuel aux endroits co ncernés.
MISE EN GARDE 309935D 5 MISE EN GARDE D ANGER EN CAS DE MA UV AISE UTILISA TION DE L ’ÉQUIPEMENT T oute mauvaise utilisation du matériel peut pr ov oquer des b le ssures gra ves , voire mortelles. • Ne pas dépasser la pression ou tempér ature de ser vice maximum spécifiée de l’élément le plus f ai- ble du syst ème.
Advertencias 6 309935D Ad ver tencias A continuación se ofrecen adve rtencias en general relacionad as con la seguridad de la puesta en marcha , utilización, conexión a tierra, mant enimiento y reparación de este equ ipo. Además, puede e ncontrar advertencias adicionales a lo largo de este ma nual siempre que sea pert inente.
ADVERTENCIAS 309935D 7 AD VERTENCIAS PELIGROS DEBIDOS A LA UTILIZA CIÓN INCORRECT A DEL EQUIPO El uso incorrecto pued e causar la muer te o heridas gra v es. • No e xceda la presión máxima de t rabajo o la temper atura del co mponente con menor v alor nominal del sistema.
8 309935D English F rançais Español 1 Displa y Afficheur Visualización 2 ON/OFF switch Bouton MARCHE/ARRÊT Interruptor de encendido/apagado 3 Pressure control Commande de la pression Dispositivo d.
309935D 9 Grounding / Mise à la te rre / Cone xión a tierra English F rançais Español The spra yer m ust be grounded. Grounding reduces the risk of static and electric shock b y providing an escape wire for the electrical current due to static build up or in the ev ent of a shor t circuit.
10 309935D P ower Requirements Extension Cords • Do no t modify plug! If it wi ll not fit in outlet, ha v e grounded outlet installed b y a qualified elec tri- cian. Do no t use an adapte r . • 100 -120V units r equire 100-120 V A C, 50/60 Hz, 11A, 1 phase.
309935D 11 Pai l s • Solvent and oil/based fluids: follo w local code. Use only con- ductive met al pails, placed on a grounded surf ace such as concrete . • Do not place pail on a nonconduc- tive surf ace such as paper or card- board which interrupts ground ing continuity .
Pressure Relief Procedure / Décompression / Desco mpresión 12 309935D Pressure Relief Procedure / Dé compression / Descompresión Pressure Relief 1 T ur n power OFF . Wa i t 7 seconds for pow er to dissipate. 2 Lock gun trigger safety . Remov e guard and SwitchTip .
Setup / Installati on / Puesta en marcha 309935D 13 Setup / Installation / Puesta en mar c ha 1 Connect Graco airless h ose to spr ay er . Tighten securely . 2 Connect other end of hose to gun. 3 Tighten securely . 4 Remov e tip guard. 1 Brancher un fle xible Gr aco type airless sur le pulvér isat- eur .
Setup / In stallation / Puesta e n marcha 14 309935D 5 Check inlet strainer f o r clogs and debris. 6 Fill throat packing nut with TSL to prev ent premature packing wear . Do this each time you spra y . 7 T ur n power OFF . 8 Plug power supply cord into a properly grounded electrical outlet.
Setup / Installati on / Puesta en marcha 309935D 15 9 T ur n prime valv e down. 10 Place siphon tube set in grounded metal pai l par tially filled with flus hing fluid. Attach ground wire to pail and to true ear th ground. Do 1. - 5. of Star tup to flush out storage oil shipped in spra yer .
Startup / Dém arrage / Puesta en marcha 16 309935D Star tup / Démarrage / Puesta en mar cha 1 T ur n pressure control to lowest pr essure. 2 T ur n pow er ON . 3 Increase pressure 1/2 to star t motor and allow fluid to circulate through drain tube for 15 seconds; turn pressure down.
Startup / Démarrag e / Puesta en marcha 309935D 17 5 Hold gun against grounded metal flushing pail. T rigger gun and increase fluid pres- sure to 1/2. Flush 1 minute. Inspect for leaks . Do not stop leaks with hand or a rag! If leaks occur , do Pressure Relief .
Startup / Dém arrage / Puesta en marcha 18 309935D 1 Inser t SwitchTip. 2 Inser t metal seal and OneSeal. 3 Screw assemb ly onto gun. Tighten. 1 Monter la buse SwitchTip . 2 Mettre un joint métallique et un joint type OneSeal. 3 Visser l’ensemble sur le pistolet.
Startup / Démarrag e / Puesta en marcha 309935D 19 Sp r ay Clear Clog 1 Spray test patter n. Adjust pres- sure to e liminate heavy edges. Use smalle r tip size if pressure adjustment can not eliminate heavy edges. 2 Hold gun per pe ndicular, 10-12 in.
Digital Tracking System / Système de sui v i numéri que / Siste ma de rastreo digital 20 309935D Digital T racking System / Système de suiv i numérique / Sistema de rastreo digital Operation Main Menu Short press mov es to next displa y . Press and hold (5 seconds) chan ges units or resets data.
Digital Trac king System / Système de suivi numé rique / Sistem a de rastreo digit al 309935D 21 Operation Main Menu 4 Press and hold to re set to zero, or short press DTS button to mov e to Lif etime Gallons (o r Liters x 10).
Digital Tracking System / Système de sui v i numéri que / Siste ma de rastreo digital 22 309935D Secondary Menu 1D o Pressure Relief, steps 1 - 4 if they hav e not already been done. 2 Press DTS button and turn power s witch ON. 3 The model (e.g. U795 ) and MO T OR ON scroll past and then total motor run hours is display ed.
Digital Trac king System / Système de suivi numé rique / Sistem a de rastreo digit al 309935D 23 Secondary Menu Change Display Units: 5 Press and hold DTS button to clear error co de to zero . 6 Shor t press DTS button. The W-D O G scrolls past and OFF is display ed.
Cleanup / Ne ttoyag e / Limpieza 24 309935D Cleanup / Netto y age / Limpieza 1D o Pressure Relief, steps 1 - 4. Remov e siphon tube set from paint and place in flush- ing fluid. NO TE: Use water f or water base paint and mineral spirits for oil base pa int.
Cleanup / Nettoy age / Limpieza 309935D 25 5 T ur n prime valv e down and allow flushing fluid to circu- late fo r 15 seconds to clean drain tube. 6 Raise siphon tube abov e flushing fluid and run spray er for 15 to 30 seconds to drain fluid. 7 Close drain valve .
Cleanup / Ne ttoyag e / Limpieza 26 309935D 9 Remov e filters from gun and spra yer , if installed. Clean and inspect. Install filters. 10 If flushing with water , flush again with mineral spirits, or Pump Armor, to lea ve a protective coating to pre- vent freezing or corrosion.
Warranty 309935D 27 Wa r r a n t y Graco warrants all equipment referenced in this document which is manuf actured by Graco and bearing its name to be free from de fe c t s i n material and workmanship on the date of sale to the origin al purc haser for use.
Warranty 28 309935D T O PLA CE AN ORDER , contact your Gr aco distributor , or call 1-800- 690-2894 to identify the nearest distrib utor . All written and visual data conta ined in this d ocument reflects the latest prod uct information available at the time of publica tion.
Ein wichtiger Punkt beim Kauf des Geräts Graco 309935d (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco 309935d noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco 309935d - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco 309935d reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco 309935d erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco 309935d besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco 309935d verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco 309935d. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco 309935d gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.