Instructions–Parts List Monark r Air Motor For use with Graco fluid handling pumps. 180 psi (1.2 MPa, 12 bar) Maximum Air Working Pressure Model 206955, Series K For ST ANCHION TUBE mounting Model 2.
2 307043 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Motor Service 6 . . . . . . . . . . . . . .
3 307043 W ARNING SKIN INJECTION HAZARD Spray from the gun/dispensing valve, leaks or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
4 307043 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
5 307043 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 4. Proper grounding is an essential part of maintaining a safe system.
6 307043 Air Motor Service Pressure Relief Procedure W ARNING SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying/dispensing acciden- tally . Fluid under high pressure can be injected through the skin and cause serious injury .
7 307043 Air Motor Service 7. Pull the piston assembly (G) from the air motor base (F), and set it aside. 8. Remove the bearing housing assembly (26 or 27) for all Models except Model 206955. Remove and wipe the seat clean with a cloth. For model 206955, remove retainer ring (3) and bearing (4).
8 307043 Air Motor Service 13. Straighten the lockwires (L*) and remove them from the upper valve nuts (J*). Screw the upper valve nuts off. Remove the trip rod yoke (O), actuator (V), and trip rod (C). 14. Unscrew the bottom valve nuts (K*), and remove the poppets (N*).
9 307043 Air Motor Service 6. Install the toggle pins (Z) in the yoke (O). As- semble the toggle assembly (U) by placing a well greased spring onto the toggle arm (T) and then the toggle rocker (S).
6 *12 13 9* 10* 11 n 31 n 14 *15 2 21 20 5 18 32 34 33 05704 n 3 n 7 25 24* 8* 9* 1 22 30 4 23* 17 19 Y 36 35 28 29 n 27 NOTE: Seal lips face upward 26 10 307043 Parts HINGED CLAMP MOUNTING: SANIT AR .
11 307043 Parts HINGED CLAMP MOUNTING: SANIT AR Y Model 207546, Series H , Air Motor Assembly Includes items 1–36 Ref. No. Part No. Description Qty . Ref. No. Part No. Description Qty . 1 1 14422 SCREW , phillips hd mach; no. 8–32 x 0.375 in. (10 mm) long.
05705B 10 *16 17 13* 14* 15 n 30 n 18 20 24 25 9 21 31 33 32 n 7 n 11 29 28* 12* 13* 1 Y 37 *19 8 27* 23 26 35 34 NOTE: Seal lips face upward 3 4 n 2 5 36 6 12 307043 Parts ST ANCHION TUBE MOUNTING Mo.
13 307043 Parts ST ANCHION TUBE MOUNTING Model 206955, Series K, Air Motor Assembly Includes items 1–37 Ref. No. Part No. Description Qty . Ref. No. Part No.
05706B n 7 *12 13 9* 10* 11 n 31 n 14 *15 3 46,18 36 6 22, 37 32 34 33 n 4 n 19 26 25* 8* 9* 1 Y 43 5 24* 17 23 40 39 29 30 n 28 NOTE: Seal lips face upward 27 21 20, 38, 44 2 14 307043 Parts Model 20.
15 307043 Parts Model 205997, Series K Air Motor Assembly Includes: 1, 3–19, 23, 25–34, 36–43 Model 215363, Series D Air Motor Assembly Includes: 1, 3–19, 21, 23, 25–34, 37–43 Model 222791, Series D Air Motor Assembly Includes: 1–23, 25–34, 39–43 Ref.
16 307043 Accessories BLEED-TYPE MASTER AIR V AL VE (REQUIRED) 300 psi (21 bar , 2.1 MPa) Maximum Working Pressure Relieves air trapped in the air line between the pump air inlet and this valve when closed.
17 307043 Dimensional Drawings 05709 1 1.75 in. (298.4 mm) 13.25 in. (336.6 mm) 15.75 in. (400.1 mm) for 206955 5.75 in. (146.1 mm) Mounting Hole Layouts Three 0.34 in. (8.6 mm) diameter holes on 6.38 in. (162.1 mm) bolt circle 3 T ie Rod Pumps 05707 05708 45_ 45_ 2.
18 307043 Graco Standard W arranty Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from de fec ts in material and workmanship on the date of sale to the original purchaser for use.
Ein wichtiger Punkt beim Kauf des Geräts Graco 207546 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Graco 207546 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Graco 207546 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Graco 207546 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Graco 207546 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Graco 207546 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Graco 207546 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Graco 207546. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Graco 207546 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.