User manual HIGH WALL SPLIT AIR CONDITIONER AHW 164.
2 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference.
3 Do not use your air conditioner when: The power cord is damaged. There is a change of liquids falling on the unit. It is close to a heat source. There is a risk of interference from foreign objects. This air conditioner is not made for DIY repair . In case of any abnormal occurrence (smoke, smell, .
4 HOW I T WORKS d b c a 7 5 6 8 1 2 3 4 The compressor (6) in the exterior unit compresses the refrigerant into a high-temperature, high-pressure gas. When this gas flows along the cooling fins of the condenser (7), heat is exuded and the gas condenses into a liquid, which is led to the evaporator (1) in the interior unit.
5 REM OTE CONTRO L LCD display: Auto mode Sleep Cool Dehumidify F an mode T emperature F an mode F an speed indicator Auto (fan, vane control) Airflow direction Clock Order of timer operation Timer Timer on Timer off T emperature set Using the remote control The remote control signal has a range of up to 8 m.
6 OPER A TION General • T urn the appliance on with the ON/OFF button . This activates the most recent setting. • The ON/OFF button turns the appliance off; the type of operation set at that time is stored in the memory . • The MODE button cycles through the various modes in this order: auto , cool , dehumidify , fan .
7 Dehumidify 1. Press the MODE button until the dehumidify symbol appears. 2. Set the desired temperature with the up and/or down -button. 3. The FAN SPEED button does not work in dehumidify mode. The fan speed will always be low in this mode. F an mode 1.
8 Air flow direction Fins (vertical vanes) Press the IN FLAP button to let the fins turn left/right for an air flow direction that is comfortable to you. Va n e s Press the OUT FLAP button to change the horizontal direction of the air flow , the vanes take these positions in sequence: .
9 FIL TE RS T o open: at the A recesses, pull the front part up. The front part will stay horizontal (turn up 60 °). T o close: press the front part down at the sides at B and in the middle at C. Make sure it is properly closed (click). 1. Hold the front part open (or put it in horizontal position) and remove the filter(s).
10 CLE ANING T urn the appliance off and disconnect the power . Interior unit Check that the condensation outlet drains properly . Dust regularly with a dry cloth or slightly damp paper towel. Never use chemicals or solvents. Never spray a liquid in or over the appliance.
11 Attention: Make sure to have the professional after-sales service person of our company or the authorized dealer to instal the units. • The units may not be installed in places where there might be leakage of combustible gases: fire hazard. • Make sure that an earth leakage circuit breaker is installed.
12 • The earth wire must be connected to the indoor unit and the outdoor unit. • The installation of the power cables must be done by qualified electricians and comply with the regulations of the local power supply authorities and with the standards for electric appliances.
13 TROU BLE SH OOTING Check the following before requesting after sales service from your dealer: The air conditioner does not operate at all. Is the unit connected to a power supply? Has the time been set? Is there a power failure or a blown fuse? Poor cooling performance.
14 RA T I N G LA B E LS Data provided is subject to modifications and is not legally binding. Made in P .R.C. Cooling capacity www.amcor group.com Refrigerant Weight net ~44 - 50 dB(A) R410A IP 20 18 kg / 40 lb Dehumification up to 40 L/day 84 pts/day 1040 m 3 /h 36700 cu.
15 NOTES.
China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgroup.
Ein wichtiger Punkt beim Kauf des Geräts Amcor AHW 164 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Amcor AHW 164 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Amcor AHW 164 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Amcor AHW 164 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Amcor AHW 164 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Amcor AHW 164 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Amcor AHW 164 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Amcor AHW 164. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Amcor AHW 164 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.