Benutzeranleitung / Produktwartung Package Heat Pump Units des Produzenten Goodmans
Zur Seite of 28
• Refer to Service Manual RS6300011 (Horizontal) for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information.
PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit.
PRODUCT IDENTIFICA TION 3 GPH1324H41AB GPH1330H41AB GPH1336H41AC GPH1342H41AB GPH1348H41BB GPH1360H41BB The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
4 PRODUCT DESIGN GPH Package Units are designed for outdoor installations only in either residential or light commercial applications. The connecting ductwork (Supply and Return) can only be connected for horizontal airflow.
PRODUCT DESIGN 5 36" 36" 24" P L E N U M U N I T P L A T F O R M C U R B Rooftop Installation - Horizontal (H) NOTE: To ensure proper condensate drainage, unit must be installed in a level position.
6 PRODUCT DESIGN ELECTRICAL DA T A (*Blower Only , Heat Mode) All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration. If heaters are not installed with above wire size, overheating and fire could occur.
PRODUCT DIMENSIONS 7 34.075 66.5 42 4. 51 2 14 . 0 00 14 . 0 00 SUP PLY 6.50 0 RE TU RN 4.500 BACK VI EW (DUC T O PENI NGS ) A 14 . 0 00 B GPH13[24-60]H41** Ch as s i s M o d el A B GP H13 24H 41* * 22 . 0 00 29 . 932 GP H13 30H 41* * 22 . 0 00 29 . 932 GP H13 36H 41* * 24 .
P ACKAGE HEA T PUMP SPECIFICA TIONS 8 GPH13[24-36]H41AB GPH1336H41AC (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min.
P ACKAGE HEA T PUMP SPECIFICA TIONS 9 (2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted. * Calculated external filter size based on air velocity of 300 ft/min. Wire size should be determined in accordance with National Electrical Codes.
ACCESSORIES 10 P a rt Nu m b e r De s cr i p t i on O T 18- 60 A O ut door T her mosta t Ki t w /Loc kout S tat O T /EHR18-60 Em e r genc y Heat Rel ay K i t HKR E l ectr ic H eat Ki t PCCP101- 103 Ro.
BLOWER PERFORMANCE DA T A 11 Dry Coil Data NOTES: 1. Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 2. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil. 3. Data shown does not include filter pressure drop, approx.
12 BLOWER PERFORMANCE DA T A 30 40 50 60 70 80 90 110 1 2 0 100 13 0 140 15 0 100 90 80 70 60 50 40 30 20 10 OUT P U T B TU/ H R x 10 0 0 BT U OUTPUT vs TEMPERAT URE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C FM FORMULA S BTU OUTPUT = CFM x 1.
13 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41* * EX PAN DE D P ER F O R M ANC E D ATA COOLIN G OP E RA TION De sign S ub c ool i ng , 1 2 ±3 °F @ t he li q ui d ac c es s f i tt ing c on nec tio n AHRI 9 5 t e st c o ndi ti ons. Des i gn Superhe a t 8 ±3 °F @ the c o mp r e s s or s uc tion a c cess fit ting c onne c t i on.
14 COOLING PERFORMANCE DA T A GPH1324H41** MOD EL: GP H 1324H41** EX PAN DE D P ER FO R M ANC E D ATA COOLIN G OP E RATION De sign Subc ool i ng , 12 ±3 °F @ the l i q ui d a cces s f i tt i ng connecti o n AHRI 95 t e st c o nd i ti ons. Des i g n Supe rhea t 8 ±3 °F @ the c om pr e s s or suction acc e ss fit ting c onne ct i on.
15 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions .
16 COOLING PERFORMANCE DA T A GPH1330H41** MOD E L : GP H 1330H41* * E XP A ND ED PE RF O RM A N CE DA T A C OOLIN G OP E R ATION De s i gn S ubc ooli ng , 1 2 ± 3 °F @ the li quid ac c e s s f i tt i ng co nne c tion AH RI 95 t es t c o nditions .
17 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L : GP H 1336H41* * E XP A ND E D PE RF ORMA N CE DA TA C OOL IN G OP E RATION De s i gn Subc oo l i n g , 1 2 ±3 °F @ the liqui d ac c es s f i tt ing c o nnec ti on AHRI 9 5 t es t c o ndi ti o ns.
18 COOLING PERFORMANCE DA T A GPH1336H41** MOD E L: GP H 1336H41** E XP A ND ED PE RF ORM A N CE DA T A COOL IN G OP E RATI O N De sign Subc o ol i ng , 12±3 °F @ the l i q ui d ac c es s f it t i n g conne c tio n AHRI 9 5 t es t c o ndi tion s.
19 COOLING PERFORMANCE DA T A GPH1342H41** MOD EL: GP H 1342 H41** EX PAN DE D P ER F O R M ANC E D ATA CO O LI N G OP E RA T I O N De s ign S ub c oo ling , 1 2± 3 °F @ t he li qu id a c ce s s f i t t i ng c on ne ct ion A R I 9 5 t e s t con d it ion s .
20 COOLING PERFORMANCE DA T A GPH1342H41** MOD E L : GP H 1342H41** EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT I ON De sig n Subc oo l i ng , 12 ±3 ° F @ the l i q ui d ac c es s f i tt i n g c onnec ti on AHRI 95 t es t c o ndi tio ns.
21 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns.
22 COOLING PERFORMANCE DA T A GPH1348H41** M O DE L: G PH1 3 4 8 H 4 1 ** EX PAN DE D P ER F O R M AN C E D ATA COO LIN G O P E RAT ION De s i gn S ubc ooli ng , 1 2 ±3 °F @ the l i qui d a c c e ss f i tt i ng c onne c tion AHRI 95 t es t c o n di ti o ns.
23 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41 * * EX PAN DE D P ER F O R M ANC E D ATA C OOL ING OP ER AT IO N D esi g n Su b co o l i n g , 12 ±3 ° F @ th e l iq u i d acc ess f itt in g co n n ec ti o n A H R I 95 t est c ond i t i o n s.
24 COOLING PERFORMANCE DA T A GPH1360H41** MOD E L : GP H 1360H41** E X P A ND ED PE RF ORM A N CE DA T A C O OL I NG OP ER AT IO N D esi g n Su b co o l i n g, 12 ±3 ° F @ t h e l iq u i d ac c ess f itt in g co n n ec ti o n A H R I 95 t est c o n d i ti o n s.
P ACKAGE HEA T PUMP SPECIFICA TIONS 25 GPH13[24-36]H41** E X PAN D ED PE RFO R M AN CE DAT A MOD E L : G P H 1324H 41* H E AT ING OPE RA TION O utdoor Am bi e nt Te m pera tur e 65 60 55 50 47 45 40 35 30 25 20 17 1 5 1 0 5 0 - 5 -10 M B h 2 7 . 72 6 .
P ACKAGE HEA T PUMP SPECIFICA TIONS 26 PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1.
WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. 27 WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T.
28 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH V OLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OUR CES M AY BE PRESEN T.
Ein wichtiger Punkt beim Kauf des Geräts Goodmans Package Heat Pump Units (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Goodmans Package Heat Pump Units noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Goodmans Package Heat Pump Units - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Goodmans Package Heat Pump Units reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Goodmans Package Heat Pump Units erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Goodmans Package Heat Pump Units besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Goodmans Package Heat Pump Units verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Goodmans Package Heat Pump Units. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Goodmans Package Heat Pump Units gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.