GDS8 & GHS8 33-3/8" 80% Gas Furnace Unit s • Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information.
PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
3 PRODUCT IDENTIFICA TION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
4 PRODUCT DESIGN NFPA 54/ANSI Z223.1 - latest edition. In Canada, the fur- naces must be vented in accordance with the National Stan- dard of Canada, CAN/CSA B149.1 and CAN/CSA B149.2 - latest editions and amendments. NOTE: The vertical height of the Category I venting system must be at least as great as the horizontal length of the venting system.
5 PRODUCT DIMENSIONS MO D EL A B G H S 80 453 A XC* 14 1/ 2 " 1 2 1/ 2" GH S 80 7 04 B X C * 17 1 / 2 " 1 6" GH S 80 9 05 C X C * 21" 1 9 1/ 2" MO D EL A B G D S 80 453 A.
6 PRODUCT DESIGN GHS8 For installations in Canada, the GHS furances are certified only to 4,500 ft. * Negative pressure readings are in inches of water column (*w.
7 PRODUCT DESIGN GDS8 Part Nu mber B1 3701 45 O p en S et t in g ( ° F ) 300 GDS 804 53A XC* 2 GDS 807 03A XC* 2 GDS 809 04B XC* 2 GDS 811 55C XC* 2 R O LL O U T L IMI T SW IT C H ES M od e l P a r t N o . O pe ns * G DS804 53A X C * B13 70142 - 0. 60 G DS807 03A X C * B1 37158 - 0.
8 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the GHS8 furnaces, in horizontal applications and for the GDS8 for downflow applications. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device).
9 PRODUCT DESIGN Thermost at s: NOTE: Complete lineup of thermostats can be found in the Thermostat Specification Sheets. Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards.
10 PRODUCT DESIGN Counterflow Filters "A" Min Return Air Opti onal Ac ce ss Door This furnace has provisions for the installation of return air filters at the counterflow top return. The furnace will accommodate the following filter sizes depending on cabinet size: Refer to Minimum Filter Area tables to determine filter area requirement.
FURNACE SPECIFICA TIONS 11 Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation.
FURNACE SPECIFICA TIONS Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information. NOTES: * These furnaces are manufactured for natural gas operation.
13 BLOWER PERFORMANCE SPECIFICA TIONS GHS8 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as high-speed cooling. Installer must adjust blower cooling speed as needed.
BLOWER PERFORMANCE SPECIFICA TIONS 14 GDS8 NOTES: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as hig-speed cooling. Installer must adjust blower cooling speed as needed.
15 BLOWER PERFORMANCE SPECIFICA TIONS 30 40 50 60 70 80 9 0 11 0 12 0 100 13 0 14 0 15 0 10 0 90 80 70 60 50 40 30 20 10 OUTP UT BTU/H R x 10 00 BTU OUTPUT vs T EM PERATURE RISE CHART TEMPERAT URE RISE 600 C FM 700 900 1000 1100 1200 140 0 1600 1800 2000 220 0 240 0 C F M FORMULAS BTU OUT PUT = CFM x 1.
16 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPL E POW ER SOUR CES MA Y BE P RESENT .
Ein wichtiger Punkt beim Kauf des Geräts Goodman Mfg GDS8 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Goodman Mfg GDS8 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Goodman Mfg GDS8 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Goodman Mfg GDS8 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Goodman Mfg GDS8 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Goodman Mfg GDS8 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Goodman Mfg GDS8 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Goodman Mfg GDS8. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Goodman Mfg GDS8 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.