© 2007 - 2012 Goodman Manufacturing Compa ny , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com - or - www .amana-hac.com P/N: IO-431 Date: May 2012 ASPF AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
2 Important Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and com- ply with all safety information and instructions accompanying these symbols.
3 IMPORTANT: To register your Goodman ® brand unit, go to www.goodmanmfg.com and click on “Warranty Registration”. Complete registration as prompted. To register your Amana ® brand unit, go to www.amana- hac.com and click “Warranty Registraion”.
4 Return Ductwork DO NOT TERMINATE THE RETURN DUCTWORK IN AN AREA THAT CAN INTRODUCE TOXIC, OR OBJECTION- ABLE FUMES/ODORS INTO THE DUCTWORK. The return ductwork is to be introduced into the air handler bottom (upflow configuration). Return Air Filters Each installation must include a return air filter.
5 H I G H V O LTA G E ! Fail ure to do so may cause prop ert y dama ge , pe r s o n a l i n ju r y or dea t h . Dis connec t ALL pow er befor e s ervi cing.
6 Low Voltage Connections Several combinations of low voltage schemes are available, depending on the presence of a heat kit and whether the heat kit is single-stage or multi-staging. The low voltage con- nections are determined by whether the outdoor unit is a con- denser or heat pump.
7 Downflow Conversion Conversion to downflow MUST be performed in an area that allows access to all sides prior to placing the air handler in its final location. To prevent the evaporator coil pan from “sweat- ing” the DPI accessory insulation kit is to be used when per- forming this conversion.
8 ASPF Model Insulation Kit 1830 DPI H36-42 3137 / 42 60 DPIH48-6 1 Table 8 The following describes converting to “Horizontal Left-Hand”. Conversion MUST be performed in an area that allows ac- cess to all sides prior to placing the air handler in its final location ( See Figure 6 ).
9 Use of a condensate removal pump is permitted when nec- essary. This condensate pump should have provisions for shutting off the control voltage should a blocked drain occur.
10 ASPF Thermostat Connections NOTES: 1) OUTDOOR THERMOSTAT (OT-1) SHOULD BE THE FIRST TO CLOSE AND THE LAST TO OPEN. 2) JUMPER W1 AND W2 TOGETHER IF OT-2 IS NOT USED.
11 HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
12 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH .
13 HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
14 THIS P AGE LEFT INTENTIONALL Y BLANK.
15 SPLIT SYSTEMS AIR CONDITIONING AND HEA T PUMP HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDA TIONS We strongly recommend a bi-annual maintenance checkup be performed before the heating and cooling seasons begin by a qualified servicer .
16 © 2007 - 2012 Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com - or - www .amana-hac.com NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Ein wichtiger Punkt beim Kauf des Geräts Goodman Mfg ASPF Air Handlers (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Goodman Mfg ASPF Air Handlers noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Goodman Mfg ASPF Air Handlers - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Goodman Mfg ASPF Air Handlers reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Goodman Mfg ASPF Air Handlers erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Goodman Mfg ASPF Air Handlers besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Goodman Mfg ASPF Air Handlers verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Goodman Mfg ASPF Air Handlers. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Goodman Mfg ASPF Air Handlers gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.