Benutzeranleitung / Produktwartung ARPF des Produzenten Goodman Mfg
Zur Seite of 13
C US ® Made in the USA by: Goodman Manufacturing Compan y , L. P. IO-230F 2550 North Loop West, Suite 400 - Houston, Texas 77092 08/04 ww w .goodmanmfg.
2 IO-230F 08/04 INDEX INTRODUCTION .................................................................... 2 REPLACEMENT P AR TS ........................................................ 2 SAFETY INSTRUCTIONS ..............................................
3 IO-230F 08/04 WARNING THIS PRODUCT IS F ACT OR Y SHIPPED FOR USE W ITH A 208-230/1/60 ELECTRICAL PO WER SUPPL Y . THIS AIR HANDLER MUST NOT BE RECONFIGURED T O OPERA TE W ITH ANY OTHER PO WER SUPPL Y . WARNING WHEN INST ALLING OR SER VICING THIS EQUIPMENT , SAFETY CLOTHING , INCLUDING HAND AND EYE PROTECTION, IS STRONGL Y ADVISED.
4 IO-230F 08/04 When matched with a Goodman or Amana brand condenser or heat pump, an ARI certified rating is available for many combinations. The AEPT models are equipped with an ECM TM moto r . An ECM TM motor is more efficient than a standard PSC motor and offers features such as soft-start, controlled off-delays, and constant CFM.
5 IO-230F 08/04 maximum heat and allow the system to reach steady state conditions. Insert two thermometers, one in the return air and one in the supply air. The temperature rise is the supply air temperature minus the room air temperature. Use HKR specification sheets to determine the HKR available for a given air handle r.
6 IO-230F 08/04 Wire Sizing W ire size is important to the operation of your equipment. Use the following check list when selecting the appropriate wire size for your unit. • Wire size must carry the Minimum Circuit Ampacity (MCA). Refer to the NEC (USA) or CSA (Canada) for wire sizing.
7 IO-230F 08/04 Piping Size For the correct tubing size, follow the specification for the condenser/heat pump. WARNING THIS COIL IS SHIPPED UNDER PRESSURE.
8 IO-230F 08/04 To increase the superheat (measured at the condenser base valve), turn the stem clockwise (in). Similarl y , to decrease the superheat, turn the stem counterclockwise (out).
9 IO-230F 08/04 To complete the conversion, slide the evaporator coil into t he chass i s and a tt ach t he t h r ee ( 3 ) access pane l s . (Figure 7). CONVERSION TO HORIZONT AL The “B” series product is not suitable for horizontal application and must not be used for this type of installation.
10 IO-230F 08/04 IMPOR T ANT NOTE: THE EV APORA T OR COIL IS COA TED WITH OILS THA T MA Y DISSOL VE STYROFOAM AND CER T AIN TYPES OF PLASTICS. THEREFORE, A REMOV AL PUMP OR FLOA T SWITCH MUST NOT CONT AIN ANY OF THESE MA TERIALS.
11 IO-230F 08/04 Humidity Control When using a Humidistat (normally closed), cut jumper PJ6 on the control board. The Humidistat will only affect cooling airflow by adjusting the Airflow to 85%. Two Stage Heating When using staged electric heat, cut jumper PJ4 on the control board.
12 IO-230F 08/04 C W2 O Y R YO C G R E W2 TYPICAL H/P ROOM THERMOSTAT HEAT PUMP AR/ARUF/ARPF/ARPT 18-60 10 KW & BELOW (OPTIONAL) OUTDOOR THERMOSTAT CLOSE ON TEMPERATURE FALL RED GREEN WHITE BLUE AR UNIT R Y O W BL #18 GA. 5 WIRE #18 GA. 7 WIRE SEE NOTE #3 R G BR W BL R E D Y E L L O W O R A N G E W H I T E B L U E #18 GA.
13 IO-230F 08/04 Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size or efficienc y . We have designed these units to significantly reduce the most frequent causes of product failure.
Ein wichtiger Punkt beim Kauf des Geräts Goodman Mfg ARPF (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Goodman Mfg ARPF noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Goodman Mfg ARPF - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Goodman Mfg ARPF reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Goodman Mfg ARPF erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Goodman Mfg ARPF besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Goodman Mfg ARPF verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Goodman Mfg ARPF. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Goodman Mfg ARPF gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.