Benutzeranleitung / Produktwartung GSZ/VSZ 13 SEER des Produzenten Goodman
Zur Seite of 55
GSZ/VSZ 13 SEER S plit System Heat Pump s • Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information.
PRODUCT IDENTIFICA TION 2 The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. WA RNI NG WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit.
PRODUCT IDENTIFICA TION 3 The United States Environmental Protection Agency (“EPA”) has issued various regulations re- garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines.
PRODUCT DESIGN 4 GSZ/VSZ13 models are available in 1 1/2 through 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt single phase applications. Select GSZ13 models are available in 208/230 and 460 volt 3-phase applications. These models use R-410A refrigerant.
PRODUCT DESIGN 5 Mo d el D i m en si o n s - W x D x H G / V SZ 130181A * 26 x 26 x 32 ¼ G / V S Z 130241A * 26 x 26 x 32 ¼ G / V S Z 130241B* 26 x 26 x 32 ½ G / V SZ 130301A * 26 x 26 x 32 ¼ G / .
HEA T PUMP SPECIFICA TIONS 6 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
HEA T PUMP SPECIFICA TIONS 7 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
HEA T PUMP SPECIFICA TIONS 8 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
HEA T PUMP SPECIFICA TIONS 9 NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
10 COOLING PERFORMANCE DA T A G/VSZ130181A* M O D E L : G /V S Z 1 3018 1A * / A R *F 182416 ** EXPA ND ED PER FOR M AN CE D ATA COOL I NG OP E RA TI ON O utdoor Am bi e n t Te m pe r ature 65 75 85 9.
11 COOLING PERFORMANCE DA T A G/VSZ130181A* M O D E L: G /V S Z 130181A * / A R * F182416* * EXPAN DED PER F O RM A NCE D ATA COOL I NG OPE RA T I ON O utdoor Am bient Te m pe r at ur e 65 75 85 95 10.
12 COOLING PERFORMANCE DA T A G/VSZ130241A* M O D E L: G /V S Z 130241A * / A R * F 182416 * * EX PANDE D PERF ORM ANCE DAT A C O O LIN G O P E R A T IO N O utdoo r Am bi e nt Te m pe r at ur e 65 75 .
13 COOLING PERFORMANCE DA T A G/VSZ130241A* M O D E L : G /V S Z 13 024 1A * / A R * F 1 824 16 * * EX PAN DE D PERF O RM ANCE DATA C OOL I NG OP E RA TI ON O utdoor Am bi e nt Te m pe r a ture 65 75 .
14 COOLING PERFORMANCE DA T A EXPAN DED PERF OR M AN CE DATA MODE L : G/ V S Z 130241B*/ AR * F 182416* * C OOLI NG OPE RA T I ON O ut door Am bie nt Te m pe r a tur e 65 75 85 95 105 115 E nt e r ing Indoor W et B ulb Te m pe r atur e ID B A i r f lo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 5 9 63 67 71 M Bh 22 .
15 COOLING PERFORMANCE DA T A G/VSZ130241B* EXPAN DED PERF OR M AN CE DATA MODE L : G/ V S Z 130241B*/ AR * F 182416* * C OOLI NG OPE RA T I ON O ut door Am bie nt Te m pe r a tur e 6 5 75 8 5 9 5 105.
16 COOLING PERFORMANCE DA T A G/VSZ130301A* M O D E L: G /V S Z 1 30301A * / A R * F 30301 * * E XP AND ED P ERF ORM AN CE D AT A COOL I NG OP E RA TI ON O utd o or Am b i e nt T e m pe r ature 65 75 .
17 COOLING PERFORMANCE DA T A G/VSZ130301A* M O D E L : G /VSZ 1 3030 1A * / A R * F 303 01* * EXPA NDED PERFO RM AN CE DA TA COOL I NG OP ER A T I ON O utdoor Am bi e n t Te m pe r at ur e 65 75 85 9.
18 COOLING PERFORMANCE DA T A G/VSZ130361A* M O D E L : G /V S Z 13 03 61A * / A R *F 36 42 16* * EXP ANDED PERF ORM ANCE D AT A C OOLIN G OPE R ATIO N O utdoor Am bient Te m pe r at ur e 65 75 85 95 .
19 COOLING PERFORMANCE DA T A G/VSZ130361A* M O D E L : G /V S Z130361A * / A R * F 364 216 * * EXPAND ED PERFO RM AN CE DA T A C OOL IN G OP E R AT ION O utd oor Am bie nt Te m pe r atur e 65 75 85 9.
20 COOLING PERFORMANCE DA T A G/VSZ130361B* EX P AND E D P ER F O RM A NC E DAT A M O D E L: G / V S Z1 3 0 36 1B * / A R * F 36 42 1 6 * * CO OL I NG OPE RATION Out d oor Ambi e nt Te mper a tur e 65.
21 COOLING PERFORMANCE DA T A G/VSZ130361B* EXP AND ED P ER FO RMANC E DAT A M O D EL: G / V SZ1 30 36 1B * / A R* F36 42 16 * * CO OL ING O PE RA T ION Out door Am bi e nt Te mpe r a ture 65 75 85 95.
22 COOLING PERFORMANCE DA T A GZ130363A* EXPAN DED PERFORMAN CE DAT A M ODEL: GS Z 130363A* / AR*F 3 64216** COOLING OP E RATION O u td oo r Am bie n t Te m pe r ature 65 75 85 9 5 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 33.
23 COOLING PERFORMANCE DA T A GZ130363A* EXPAN DED PERFORMAN CE DA T A M ODEL: GS Z 130363A* / AR*F 3 64216** COOLING OP E RATION O u td oo r Am bie n t Te m pe r ature 65 75 85 9 5 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 7 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 34.
24 COOLING PERFORMANCE DA T A G/VSZ130421A* M O D E L : G /V S Z 130421A * / A R * F 36421** EX PANDED PERF ORM ANCE DATA COOL I NG OP ER A T I ON O utdoo r Am b i e nt Te m pe r ature 65 7 5 85 95 1 .
25 COOLING PERFORMANCE DA T A G/VSZ130421A* M O D E L: G /V S Z 130421 A * / A R * F 36421* * E XPANDE D PERF ORM ANCE DATA COOL I NG OP ERA T I ON O utdoo r Am bie nt T e m p e r ature 65 75 85 95 10.
26 COOLING PERFORMANCE DA T A G/VSZ130481A* M O D E L : G /V S Z 130481A * /A R *F 48601* * EXPAN DED PER FORM AN CE DA T A COOL I NG OP ERA T I ON O utdoor Am bi e nt Te m pe r at ur e 65 75 85 95 10.
27 COOLING PERFORMANCE DA T A G/VSZ130481A* M O D E L : G /VSZ 130481A * /A R *F 48601** EXPAN DED PERFOR M ANC E DATA COOL I NG OP ERA T I ON O utdoor Am bi e nt Tem pe r at ur e 65 75 85 95 105 115 .
28 COOLING PERFORMANCE DA T A GSZ130483A* EXPAN DED PERFORMAN CE DA T A M ODEL: GS Z 130483A* / AR*F 4 86016** COOLING OP E RATION O u td oo r Am bie n t Te m pe r ature 65 75 85 9 5 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 7 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 45.
29 COOLING PERFORMANCE DA T A GSZ130483A* EXPAN DED PERFORMAN CE DA T A M ODEL: GS Z 130483A* / AR*F 4 86016** C OOLING O P E RA TION O u td oo r Am bie n t Te m pe r ature 65 75 85 95 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 7 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 46.
30 COOLING PERFORMANCE DA T A GSZ130484A* EXPAN DED PERFORMAN CE DA T A M ODEL: GS Z 130484A* / AR*F 4 86016** COOLING OP E RATION O u td oo r Am bie n t Te m pe r ature 65 75 85 9 5 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 7 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 45.
31 COOLING PERFORMANCE DA T A GSZ130484A* EXPAN DED PERFORMAN CE DA T A M ODEL: GS Z 130484A* / AR*F 4 86016** COOLING OP E RATION O u td oo r Am bie n t Te m pe r ature 65 75 85 9 5 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 7 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 46.
32 COOLING PERFORMANCE DA T A G/VSZ130601A* M O D E L : G /V S Z 130601A * / A R * F48601* * EXPAND ED PERFO RM ANC E DATA COOL I N G OPE R ATI ON O utdoor Am bi e nt Te m pe r at ur e 65 75 85 95 105.
33 COOLING PERFORMANCE DA T A G/VSZ130601A* EX PANDED P ERF ORM ANCE DAT A C OOL I N G OP E R AT ION M ODEL: GS Z 130601A * / AR*F 48601** O utdoor Am bi e nt Tem pe r at ur e 65 75 85 95 105 11 5 E nter i ng Indoor Wet B ul b Te m pe ra ture ID B A ir f low 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 M Bh 55.
34 COOLING PERFORMANCE DA T A GSZ130603A* EXPAN DED PERFORMAN CE DA T A M ODEL: GS Z 130603A* /AR*F 4 86016** COOLING OP E RATION O u td oo r Am bie n t Te m pe r ature 65 75 85 9 5 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 7 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 55.
35 COOLING PERFORMANCE DA T A GSZ130603A* EXPAN DED PERFORMAN CE DA T A M ODEL: GS Z 130603A* /AR*F 4 86016** C OOLING O P E RA TION O u td oo r Am bie n t Te m pe r ature 65 75 85 95 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 7 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 57.
36 COOLING PERFORMANCE DA T A GSZ130604A* EXPAN DED PERFORMAN CE DA T A M ODEL: GS Z 130604A* /AR*F 4 86016** COOLING OP E RATION O u td oo r Am bie n t Te m pe r ature 65 75 85 9 5 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 7 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 55.
37 COOLING PERFORMANCE DA T A GSZ130604A* EXPAN DED PERFORMAN CE DA T A M ODEL: GS Z 130604A* /AR*F 4 86016** COOLING OP E RATION O u td oo r Am bie n t Te m pe r ature 65 75 85 9 5 105 115 E nte r i ng I ndoor Wet B ul b Te m pe rature ID B A ir flow 59 63 67 71 59 63 67 7 1 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6 7 71 M Bh 57.
38 SPLIT SYSTEM HEA TING PERFORMANCE M OD EL : G/ V S Z 13 01 81A * / AR* F 1 8 24 1 6 ** HEAT I NG O PE RA T I O N O utdoor Am bi e nt Te m p e r at u r e 65 60 5 5 50 4 7 45 4 0 35 30 25 2 0 17 15 1 0 5 0 - 5 -1 0 MB h 21. 4 20 .2 1 9. 0 17. 8 17 .0 16 .
39 SPLIT SYSTEM HEA TING PERFORMANCE EXP ANDED PERFORMANCE DA T A *Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature Hi g h pre s su r e i s m eas u red at t h e l iqu id s er v ic e v al v e ( t h e s ma lle r val v e ) .
40 SPLIT SYSTEM HEA TING PERFORMANCE EXP ANDED PERFORMANCE DA T A *Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature Hi g h pre s su r e i s m eas u red at t h e l iqu id s er v ic e v al v e ( t h e s ma lle r val v e ) .
41 SPLIT SYSTEM HEA TING PERFORMANCE EXP ANDED PERFORMANCE DA T A *Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature Hi g h pre s su r e i s m eas u red at t h e l iqu id s er v ic e v al v e ( t h e s ma lle r val v e ) .
42 EXP ANDED PERFORMANCE DA T A SPLIT SYSTEM HEA TING PERFORMANCE *Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature Hi g h pre s su r e i s m eas u red at t h e l iqu id s er v ic e v al v e ( t h e s ma lle r val v e ) .
43 SPLIT SYSTEM HEA TING PERFORMANCE EXP ANDED PERFORMANCE DA T A *Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature Hi g h pre s su r e i s m eas u red at t h e l iqu id s er v ic e v al v e ( t h e s ma lle r val v e ) .
44 SPLIT SYSTEM HEA TING PERFORMANCE *Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature Hi g h pre s su r e i s m eas u red at t h e l iqu id s er v ic e v al v e ( t h e s ma lle r val v e ) . L ow pr e ss u r e i s me a s u re d a t th e gau ge po r t c on nec ti on .
45 SPLIT SYSTEM HEA TING PERFORMANCE *Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature Hi g h pre s su r e i s m eas u red at t h e l iqu id s er v ic e v al v e ( t h e s ma lle r val v e ) . L ow pr e ss u r e i s me a s u re d a t th e gau ge po r t c on nec ti on .
46 See Heating Mode chart on following page. Chart applies to GSZ130481A, GSZ130483A & GSZ130484A. EXP ANDED PERFORMANCE DA T A SPLIT SYSTEM HEA TING PERFORMANCE M O D EL: G / V S Z 1304 81A * / AR * F 486 01** HE AT I NG O P ERA TI O N Outdo or Am b i ent T em p e r atur e 65 60 5 5 50 4 7 45 4 0 35 30 25 2 0 17 15 1 0 5 0 - 5 -1 0 MB h 55.
47 SPLIT SYSTEM HEA TING PERFORMANCE EXP ANDED PERFORMANCE DA T A *Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature Hi g h pre s su r e i s m eas u red at t h e l iqu id s er v ic e v al v e ( t h e s ma lle r val v e ) .
48 SPLIT SYSTEM HEA TING PERFORMANCE EXP ANDED PERFORMANCE DA T A MO D E L : G /VS Z1 3 0 6 0 1 A * / A R * F4 8 6 0 1* * H EA TIN G OPE R A T IO N O utdoor Am bi ent Temp e r a tur e 65 60 5 5 50 4 7 45 4 0 35 30 25 2 0 17 15 1 0 5 0 - 5 -1 0 MB h 72.
49 SPLIT SYSTEM HEA TING PERFORMANCE EXP ANDED PERFORMANCE DA T A *Note: Shaded area is AHRI Rating Conditions at 47° outdoor ambient temberature Hi g h pre s su r e i s m eas u red at t h e l iqu id s er v ic e v al v e ( t h e s ma lle r val v e ) .
50 PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1.
HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPLE POW ER SOUR CES MA Y BE P RESENT . F AI LURE TO DO SO MA Y CAUS E PROP ERTY DAMAGE, PERSONAL IN JUR Y OR DE A TH . WIRING DIAGRAMS 51 Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
WIRING DIAGRAMS 52 HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPLE POW ER SOUR CES MA Y BE P RESENT . F AI LURE TO DO SO MA Y CAUS E PROP ERTY DAMAGE, PERSONAL IN JUR Y OR DE A TH . U SE N. E. C . CL AS S 2 WIRE NO TES: 1) T O IND OO R UNIT L OW VOL T AGE TERMINAL BLOCK & I N DO OR THERM OST A T .
HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPLE POW ER SOUR CES MA Y BE P RESENT . F AI LURE TO DO SO MA Y CAUS E PROP ERTY DAMAGE, PERSONAL IN JUR Y OR DE A TH .
WIRING DIAGRAMS 54 HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPLE POW ER SOUR CES MA Y BE P RESENT . F AI LURE TO DO SO MA Y CAUS E PROP ERTY DAMAGE, PERSONAL IN JUR Y OR DE A TH . Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL T IPLE POW ER SOUR CES MA Y BE P RESENT . F AI LURE TO DO SO MA Y CAUS E PROP ERTY DAMAGE, PERSONAL IN JUR Y OR DE A TH . WIRING DIAGRAMS 55 Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
Ein wichtiger Punkt beim Kauf des Geräts Goodman GSZ/VSZ 13 SEER (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Goodman GSZ/VSZ 13 SEER noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Goodman GSZ/VSZ 13 SEER - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Goodman GSZ/VSZ 13 SEER reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Goodman GSZ/VSZ 13 SEER erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Goodman GSZ/VSZ 13 SEER besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Goodman GSZ/VSZ 13 SEER verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Goodman GSZ/VSZ 13 SEER. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Goodman GSZ/VSZ 13 SEER gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.