Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual For Models: P217 P218 P219 P220 P221 P227 P230 Series P 200A -18mm versions Contents: Installation Instructions: page 2 P.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
P217A HORSEPOWE R REQUIREM ENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.3 0.2 0.3 0.4 0.4 500 0.5 0.4 0.5 0.7 0.9 1000 1.0 0.7 1.1 1.4 1.8 1450 1.5 1.0 1.5 2.1 2.6 1750 1.8 1.2 1.9 2.5 3.1 3000 2.9 2.0 3.0 4.0 5.0 3200 3.1 2.1 3.2 4.2 5.3 3450 3.
P218A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.5 0.3 0.5 0.7 0.8 500 1.0 0.7 1.0 1.3 1.7 1000 1.9 1.3 2.0 2.7 3.4 1450 2.
P219A HORSEPOWER REQUIREM ENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.6 0.4 0.6 0.8 1.0 500 1.2 0.8 1.2 1.7 2.1 1000 2.4 1.7 2.5 3.3 4.1 1450 3.
6 Specifications Model P220A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
P221A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.3 0.2 0.3 0.5 0.6 500 0.7 0.5 0.7 0.9 1.2 1000 1.3 0.9 1.4 1.8 2.3 1450 1.9 1.3 2.0 2.7 3.3 1750 2.3 1.6 2.4 3.2 4.0 3000 3.7 2.5 3.8 5.0 6.3 3200 3.9 2.7 4.0 5.4 6.7 3450 4.
P227 HORSEPOWER R EQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.3 0.2 0.3 0.4 0.5 500 0.6 0.4 0.6 0.8 1.0 1000 1.2 0.8 1.2 1.7 2.1 1450 1.7 1.2 1.8 2.4 3.0 1750 2.1 1.4 2.2 2.9 3.6 3000 3.3 2.3 3.4 4.6 5.7 3200 3.5 2.4 3.6 4.9 6.1 3450 3.
P230 HORSEPOWER REQUIREMEN TS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.2 0.1 0.2 0.2 0.3 500 0.3 0.2 0.3 0.4 0.5 1000 0.6 0.4 0.7 0.9 1.1 1450 0.9 0.6 0.9 1.3 1.6 1750 1.1 0.8 1.1 1.5 1.9 3000 1.8 1.2 1.8 2.5 3.1 3200 1.9 1.3 2.0 2.6 3.3 3450 2.
10 Exploded View P217/P218/P219/P220/P221/P227/P230 Pump s.
ITEM PART NO. DESCRIPTION QTY. 1 6A 08468 Plunger Base 3 16B 08455 Plunger Pipe 3 16C 08456 Tension Screw 3 1 6D 07676 Copper Gasket 3 17 08442 Wrist Pin 3 18 07770 O-Ring 3 19 08356-0010 Oil Seal 3 2.
12 Rep air Kit s P217/P218/P219/P220/P221/P227/P230 Pump s Plunger Packing Kit Part # 09164 Item # Part # Description Qty. 23 08477 V-Sleeve, weep 3 2 3A 08087 V-Sleeve, brown 3 24 07904 Pressure Ring 3 Valve Assembly Kit Part # 09116 Item # Part # Description Qty.
13 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace.
REPAIR INSTRUCTIONS - P217/P218/P219/P220/P221/P227/P230 PUMPS 10 NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.
15 Reassembly sequence of the P217/P218/P219/P220/P221/P227/P230 pumps 1 ) If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before replacing. 2 ) Replace seal case (20) with o-rings (21) over plungers. Generously lubricate o-rings and oil seal before reassembly.
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period.
Ein wichtiger Punkt beim Kauf des Geräts Giant P230 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Giant P230 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Giant P230 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Giant P230 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Giant P230 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Giant P230 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Giant P230 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Giant P230. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Giant P230 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.