Benutzeranleitung / Produktwartung 5500XL des Produzenten Generac Power Systems
Zur Seite of 18
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Problems? Questions? Before t aking your unit back to the store, call the generator helpline at 1-800-270-1408 M-F 8-5 CT Model No.
Generac Portable Product s 5500XL Extended Life Generator 2 EQUIPMENT DESCRIPTION This generator is an engine-driven, revolving field, alternating current (AC) generator . It was designed to supply electrical power for operating compatible electrical lighting, appliance, tool and motor loads.
Generac Portable Product s 5500XL Extended Life Generator 3 Never handle any kind of electrical cord or device while standing in water , while barefoot, or while hands or feet are wet.
Generac Portable Product s 5500XL Extended Life Generator 4 12 V olt DC, 10 Amp Receptacle Recharge a discharged 12 V olt automotive type battery through this receptacle.
Generac Portable Product s 5500XL Extended Life Generator 5 BEFORE ST ARTING THE ENGINE Add Oil W ARNING! Any attempt to crank or start the engine before it has been properly filled with the recommended oil may result in an engine failure. Place generator on a level surface.
Generac Portable Product s 5500XL Extended Life Generator 6 OPERA TING THE GENERA T OR CAUTION! Never start or stop the unit with electrical loads connected to the receptacles AND with the connected devices turned ON. St arting the Engine DANGER! Never run engine indoors or in enclosed poorly ventilated areas.
Generac Portable Product s 5500XL Extended Life Generator 7 Stopping the Engine Unplug all electrical loads from generator panel receptacles. Never start or stop engine with electrical devices plugged in and turned on. Put the Idle Control switch in the Off position.
Generac Portable Product s 5500XL Extended Life Generator 8 COLD WEA THER OPERA TION Under certain weather conditions (temperatures below 40°F [4°C] and a high dew point), your generator may experience icing of the carburetor and/or the crankcase breather system.
Generac Portable Product s 5500XL Extended Life Generator 9 120 V olt AC, 30 Amp Locking Recept acle Use a NEMA L530 plug with this receptacle. Connect a 3wire cord set rated for 125 V olts AC at 30 Amps to the plug (Figure 8). Use this receptacle to operate 120 V olt AC, 60 Hz, single phase loads requiring up to 3,600 watts (3.
Generac Portable Product s 5500XL Extended Life Generator 10 DONT OVERLOAD THE GENERA T OR Overloading a generator in excess of its rated wattage capacity can result in damage to the generator and/or connected electrical devices.
Generac Portable Product s 5500XL Extended Life Generator 11 GENERAL MAINTENANCE RECOMMENDA TIONS The owner/operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored.
Generac Portable Product s 5500XL Extended Life Generator 12 Problem Ca use Corre ction Engine is running, but no A C output is av ailabl e. 1. Circuit breakers i s open. 2. Poor connection or de fective cord set. 3. Connected devi ce is bad. 4. Fault in gen erator.
Generac Portable Product s 5500XL Extended Life Generator 13 Item Part # Qty Description 1 A92070 1 Control Panel 2 23897 4 #10 (M5) Flat W asher 3 49226 4 M5 Lock Washer 4 91526 4 M5-0.8 x 12mm Screw 5 82538 1 Idle Control Switch 6 82881 4 7/16" Lock W asher 7 43181 4 M3-0.
Generac Portable Product s 5500XL Extended Life Generator 14 ELECTRICAL SCHEMA TIC.
Generac Portable Product s 5500XL Extended Life Generator 15 WIRING DIAGRAM.
Generac Portable Product s 5500XL Extended Life Generator 16 EXPLODED VIEW UNIT.
Generac Portable Product s 5500XL Extended Life Generator 17 Item Part # Qty . Description 1 A92432 1 CRADLE 2 A92531 1 SUPPORT , Engine 3 A92731 1 SUPPORT , Engine & Muffler 4 92247 1 HOUSING , E.
LIMITED W ARRANTY FOR "GN" ENGINE DRIVEN PORT ABLE GENERA TORS GENERAC PORT ABLE PRODUCTS (hereafter referred to as the COMP ANY) warrants to the original purchaser that the alternator and c.
Ein wichtiger Punkt beim Kauf des Geräts Generac Power Systems 5500XL (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Generac Power Systems 5500XL noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Generac Power Systems 5500XL - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Generac Power Systems 5500XL reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Generac Power Systems 5500XL erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Generac Power Systems 5500XL besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Generac Power Systems 5500XL verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Generac Power Systems 5500XL. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Generac Power Systems 5500XL gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.