Benutzeranleitung / Produktwartung CP7317RS des Produzenten Altinex
Zur Seite of 16
CONTROLLERS CP7317RS RS – 232 CONTROLLER USER’S GUIDE MANUAL PART NO. 400-0017-003 PRODUCT REVISION: 0.
CONTROLLERS 1 INTRODUCTION Thank you for purchasing the CP7317RS RS-232 Controller. We are sure you will find it a reliable and useful product. Superior performance for the right price backed by solid technical and customer support is what we have to offer.
CONTROLLERS 2 PRECAUTIONS / SAFETY WARNINGS 1 Please read this manual carefully before using your CP7317RS RS-232 Controller. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your CP7317RS and to prevent fire and shock hazard.
CONTROLLERS 3 ABOUT CP7317RS - RS-232 CONTROLLER 2 The CP7317RS RS-232 Controller is designed to provide expanded capabilities to any control system. The CP7317RS is designed to accept RS- 232 commands from a control device and output those commands as relay contacts or digital high or low.
CONTROLLERS 4 CP7317RS DESCRIPTION 4 CP7317RS FEATURES 4.1 RS-232 PORT This port (located next to the power outlet) is a fully programmable, bi-directional, and full duplex port that has the ability to operate at any baud rate up to 9600. The general standard on transmission is 8 bits, no parity, and 1 stop bit.
CONTROLLERS 5 The following table shows the pin-outs on the connector corresponding to the following I/O port pin numbers. Connector Pin No. 1 2 3 4 5 6 7 8 9 I/O Port Pin No. 1 3 5 7 9 Ground 2 4 6 8 There are 4 ports with 8 I/O pins and one ground pin, #5 on each port.
CONTROLLERS 6 4.7 PROGRAMING COM MANDS The commands below are used for presetting the default status of the unit. Note: AFTER USING THE PROGRAMMING COMMANDS LISTED BELOW, THE CP7317RS SHOULD BE POWERED OFF AND THEN ON. [SETIp,b,n] This command sets individual pins of each I/O port to input or output status.
CONTROLLERS 7 b This letter defines the status of a pin, while its position in a string number corresponds to the pin number on the I/O Port of the CP7317RS . For example b 4 represents the status of Pin 4 on the I/O connector. The valid pins on I/O port are from 1 to 9 except 5.
CONTROLLERS 8 FIGURE 6: Input/Output Port Pin Configuration n This letter designates the status of the pin as either high or low during “Power up” of the unit. when n = 1 the pin is set as high when n = 0 the pin is set as low Example: Set pin 1 of port 3 as low during POWER ON.
CONTROLLERS 9 n This letter designates the status of the relay during “Power up”. n=1 relay is open n=0 relay is closed Example: Set relay 6 of port 2 to be open at power up.
CONTROLLERS 10 Bit No. Connector Pin No. 7 4 8 9 n Data that defines the status of the pin n=1 or n=0. [SETDp, b 1 b 6 b 2 b 7 b 3 b 8 b 4 b 9 ] SET all pins on the particular I/O port of the unit. This command defines if I/O port pins will be high or low.
CONTROLLERS 11 [READDp] Read Digital status of a particular port. The feedback is in the following format [10011100] 1 is for high 0 is for low. The feedback provides status of all pins. Left most character is a bit pin number 1. p Port number, this is an ASCII character from 1 to 4 that matches the port number on the back of the CP7317RS .
CONTROLLERS 12 4.10.1. MEMORY 1 I/O port/memory is A Sub-Register address is from 00 to 255 Sub-Register definitions 00 This location should be set to FFh i f memory initialization is required. During the power up sequence this location is checked for software revision.
CONTROLLERS 13 33 Power up status of relays on port 2,3,4. If bit is set to 0 then relay will be closed on power up. If bit is set to 1 then relay will be open on power up. 34 Left bracket for beginning command code. Factory set to “[“. 35 Right bracket for ending command code.
CONTROLLERS 14 08 00-07 locations for return code for port 1 pin 2 for transition from 0 to 1. This return code should include any necessary brackets. .
CONTROLLERS 15 ALTINEX POLICY 5 5.1 LIMITED WARRANTY Altinex warrants that its products and cables are free from defects in materials under normal use and service. This warranty is limited to repairing at company’s factory any part or parts of the product, which upon company’s examination shall disclose to be, thus defective.
Ein wichtiger Punkt beim Kauf des Geräts Altinex CP7317RS (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Altinex CP7317RS noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Altinex CP7317RS - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Altinex CP7317RS reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Altinex CP7317RS erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Altinex CP7317RS besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Altinex CP7317RS verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Altinex CP7317RS. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Altinex CP7317RS gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.