Benutzeranleitung / Produktwartung MX130 S2 des Produzenten Fujitsu
Zur Seite of 256
Upgrad e and Mai ntena nce Manu al - English PRIMERGY MX130 S2 Server Upgr ade and Mai ntena nce Ma nual Edition November 201 1.
Comments … Suggestions … Corrections … The User Documentation Department w ould like to know your opinion of this manual. Y our feedback helps us optimize our documentation to suit your individual needs. Feel free to se nd us your co mments by e-mail to manuals@ts.
MX130 S2 Upgrade and Maintenance Manual 3 Before reading this manua l For your safety This manual cont ains important i nformation for safely and correctly using this product.
4 Upgrade and Maintenance Man ual MX130 S2 These uses include control of nuclear reactions in nuclear power plant s , automatic airplane fl ight control, air traffi c control, traffic c ontrol in mass transport systems, medical devices for life support, and missi le guidance control in weapons systems (hereaf ter , " high safety use ").
MX130 S2 Upgrade and Maintenance Manual 5 Content s V ersion history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 1.1 Where to find which info rmation? . . . . .
6 Upgrade and Maintenance Man ual MX130 S2 Contents 4.3 Opening the front cage . . . . . . . . . . . . . . . . . . . . . 52 4.4 Closing the front cage . . . . . . . . . . . . . . . . . . . . . . 53 4.5 Closing the server . . . . . . . . . . . . . . . .
MX130 S2 Upgrade and Maintenance Manual 7 Contents 7 HDDs and accessible drives . . . . . . . . . . . . . . . . . . 79 7.1 Basic procedure . . . . . . . . . . . . . . . . . . . . . . . . 81 7.2 Mounting order . . . . . . . . . . . . . . . . . . . . . .
8 Upgrade and Maintenance Man ual MX130 S2 Contents 7.9 Inst alling addition al 3.5-inch HDD in 5.25-inch ODD/HDD bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 7.9.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . .
MX130 S2 Upgrade and Maintenance Manual 9 Contents 7.16 Removing slimline ODD out of 5.25-inch ODD/HDD bracket . . . . . . . . . . . . . . . . . . . . . . . 125 7.16.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 125 7.16.2 Preliminary steps .
10 Upgrade and Maintenanc e Manual MX130 S2 Contents 9 Expansion car ds . . . . . . . . . . . . . . . . . . . . . . . . 159 9.1 Basic procedure . . . . . . . . . . . . . . . . . . . . . . . . 160 9.2 Expansion car ds . . . . . . . . . . . . . . . . . .
MX130 S2 Upgrade and Maintenance Manual 11 Contents 10.2 Installing memory modules . . . . . . . . . . . . . . . . . . 182 10.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 182 10.2.2 Preliminary steps . . . . . . . . . . . . .
12 Upgrade and Maintenanc e Manual MX130 S2 Contents 12.2 T rusted Plat form Module (TPM) . . . . . . . . . . . . . . . . 204 12.2.1 Install ing the TPM board . . . . . . . . . . . . . . . . . . . . 204 12.2.1.1 Required tools . . . . . . . . . . . . .
MX130 S2 Upgrade and Maintenance Manual 13 Contents 14.1.1 Overview of used cables . . . . . . . . . . . . . . . . . . . . . 234 14.2 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 14.2.1 Power cabling . . . . . . . . . . . . . .
14 Upgrade and Maintenanc e Manual MX130 S2 Contents.
MX130 S2 Upgrade and Maintenance Manual 15 V ersi on history Issue number Reason for update Initial r elease.
16 Upgrade and Maintenanc e Manual MX130 S2 V ersion history.
MX130 S2 Upgrade and Maintenance Manual 17 1 Intro duction This Upgrade and Maintenance Manual prov ides instructions for the following procedures: ● Upgrading the server configuration by adding optional hardware components ● Upgrading the server configurati on by replacing existing hardware components with superior ones.
18 Upgrade and Maintenanc e Manual MX130 S2 Introductio n 1.1 Where to find which information? While the Upgrade and Maintenanc e Manual focuses on upgrade and maintenance procedures to bring the server back to normal operation, additional manuals provide det ailed background information on server components and BIOS settings.
MX130 S2 Upgrade and Maintenance Manual 19 Introductio n 1.2 Notational conventions The following notati onal conventions are used in this manual: T ext in italics indi c ates commands or menu items f.
20 Upgrade and Maintenanc e Manual MX130 S2 Introductio n.
MX130 S2 Upgrade and Maintenance Manual 21 2 Bef ore you start Before you start any upgrade or maintenance t ask, please proceed as follows: Ê Carefully read the safety instructions in c hapter "Important information" on page 31 . Ê Make sure that all necessary m anuals are available.
22 Upgrade and Maintenanc e Manual MX130 S2 Before you start Please contact your local Fujits u customer service partner for details on how to order expansion kits or spare part s. Us e the Fujitsu Illustrated S pares Catal og to identify the required spare p art and obtain technical data and order information.
MX130 S2 Upgrade and Maintenance Manual 23 Before you start 2.1 Classification of procedures The complexity of maintenance procedures varies signifi cantly . Procedures have been assigned to one of three unit categories, indicating the lev el of diffi c ulty and required qualific ation.
24 Upgrade and Maintenanc e Manual MX130 S2 Before you start 2.1.2 Upgrade and Rep air Units (URU) Upgr ade and Re pair U nits are non hot-plug components that can b e ordered separately to be install ed as options ( Upgrade Units ). Upgrade and repair procedures involve shutting down and opening the s erver .
MX130 S2 Upgrade and Maintenance Manual 25 Before you start 2.1.3 Field R eplaceable Units (FRU) Removing and inst alling Field Replaceable Units involves comp lex maintenance procedures on integral server components. Procedures will require shutting down, opening and disassembling the server .
26 Upgrade and Maintenanc e Manual MX130 S2 Before you start 2.2 A v erag e task du rati on The average task duration inc l uding preliminary and concludi ng s tep s is indicated at the beginning of eac h procedure next to the procedure class.
MX130 S2 Upgrade and Maintenance Manual 27 Before you start 2.3 T ools you need at hand When preparing the maintenanc e task, ensure that all required tools are available according to the overview below . Y ou will find a list of required tools at the beginning of each procedure.
28 Upgrade and Maintenanc e Manual MX130 S2 Before you start 2.4 Documents you need at hand Maintenance procedures may include references to additional document ation. When preparing the main tenance task, ensure that all required manuals are available according to th e ov erview below .
MX130 S2 Upgrade and Maintenance Manual 29 Before you start Glossa ry available from the S er verV iew Suite DVD 2 or online at http://manuals.ts.fujit su.
30 Upgrade and Maintenanc e Manual MX130 S2 Before you start.
MX130 S2 Upgrade and Maintenance Manual 31 3 Import ant informa tion V CAUTION! Before install ing and starting up a devic e, please observ e the safety instructions listed i n the following section. This will help you to avoid making serious errors that could imp air your health, damage the device and endanger the data base.
32 Upgrade and Maintenanc e Manual MX130 S2 Important information ● If the device is brought in from a c old environment, condensation may form both inside and on the outs i de of the device. W ait until the device has acclimatized to room temp er ature and is absolutely dry before starting i t up.
MX130 S2 Upgrade and Maintenance Manual 33 Important informatio n ● Ethernet cabling has to comply wi th EN 50173 and EN 50174-1/2 st andar ds or ISO/IEC 1 1801 standard respectively . The minimum requirement is a Category 5 shielded cable for 10/100 Ethernet, or a Category 5e cable for Gigabit Ethernet.
34 Upgrade and Maintenanc e Manual MX130 S2 Important information ● Do not damage or modify internal c ables or devices. Doing so may cause a device failure, fire, or electric shock and will v oid the warranty and exempt the manufacturer from all liability .
MX130 S2 Upgrade and Maintenance Manual 35 Important informatio n Batteries ● Incorrect replacement of batteries ma y lead to a risk of explos ion. The batteries may only be replaced with i dentic al batteries or with a type recommended by the manufacturer .
36 Upgrade and Maintenanc e Manual MX130 S2 Important information ● High humidity and airborne dust levels are to be avoided. El ec tric shocks and/or server failures may be caused by liquids such as water , or metallic items, such as pape r clip s , entering a drive.
MX130 S2 Upgrade and Maintenance Manual 37 Important informatio n I Y ou can prevent damage from the ODD and the CDs/DVDs/BDs, as well as premature wear of the disks, by observing the following suggestions: – Only insert disks in the drive when needed and remove them af ter use.
38 Upgrade and Maintenanc e Manual MX130 S2 Important information ● Any devices or tools that are used must be free of electrostatic charge. ● Wear a suit able grounding cable that connects you to the external chassis of the system unit. ● Always hold component s with ESDs at the edges or at the point s marked green (touch points).
MX130 S2 Upgrade and Maintenance Manual 39 Important informatio n 3.2 ENERGY ST A R I Energy S tar is applicable onl y for 230 V mains volt age. ENERGY ST AR does not apply to the Japanese market. In typical confi gurations the PRIMERG Y MX130 S2 satisfies the stringent requirements of the Ecolabel Energy St ar for Computers V ersion 5.
40 Upgrade and Maintenanc e Manual MX130 S2 Important information The system has a hibernate mode (S4 mode) from which it can be woken up via WOL (W ake-up On LAN). In order to use this feature, however , the S4 mode must be activated/enabled i n the corr esponding operating system installed.
MX130 S2 Upgrade and Maintenance Manual 41 Important informatio n Exiting the hibernate/ idle state (S4 mode) Y ou switch on the system again ei ther manually using the On/Off button or usi ng the WOL function (WOL= W ake-up On LAN).
42 Upgrade and Maintenanc e Manual MX130 S2 Important information 3.3 C E conformi ty The system complies with the requirements of the EC directives 2004/108/EC regarding "Electromag netic Compatibi lity" and 2006/95/EC "Low V oltage Directive".
MX130 S2 Upgrade and Maintenance Manual 43 Important informatio n 3.4 FCC Class A Compliance S t atement If there is an FCC statement on the device, it appli es to the product s covered in this manual, unless otherwise specifi ed herein. The statement for other products will appear in the ac companyi ng documentation.
44 Upgrade and Maintenanc e Manual MX130 S2 Important information 3.5 Environm ent al protection Environmentally-friendly prod uct design and development This product has been designed in accordance with the Fujit s u standard for "environmental ly friendly product design and dev elopment".
MX130 S2 Upgrade and Maintenance Manual 45 Important informatio n Labels on plastic casing part s Please avoid sticking your own labels on plastic parts wherever possible, since this makes it dif fi cult to recycle them. Returns, recycling and disposal Please handle returns, recycling and dis pos al in accordance with loc al regulations.
46 Upgrade and Maintenanc e Manual MX130 S2 Important information.
MX130 S2 Upgrade and Maintenance Manual 47 4 Basic h a rdware proce dures 4.1 Using diagnostics information The "PRIMERGY MX130 S2 Server Operating manual" gives an introduction to server features and provides an overview of available hardware options.
48 Upgrade and Maintenanc e Manual MX130 S2 Basic hardware procedures 4.2 Ope nin g the ser ver V CAUTION! ● Before removing or installi ng covers, turn off the server and all peripheral devices. Also unplug al l power c ables from the outlet. Failure to do so can cause electric shock.
MX130 S2 Upgrade and Maintenance Manual 49 Basic hardware procedures Figure 2: Power button on the front panel Ê Shut down the server . I If the system is running an ACPI-compliant operating system, pressing the On / Off button will perform a graceful shutdown.
50 Upgrade and Maintenanc e Manual MX130 S2 Basic hardware procedures Only for Jap an: Disconnecting cable tie Figure 4: Removing the cable tie Ê Pull out on the loc k ing lever on the PSU cabl e tie (1) and loosen the loope (2). Ê Disconnect the power cord from the PSU module and remove it from the cable tie.
MX130 S2 Upgrade and Maintenance Manual 51 Basic hardware procedures 4.2.2 Removing the s e rver c over Figure 5: Unlocking the locking bar Ê Slide the locking bar to the lef t until it rests in place. Figure 6: Removing the server cover Ê Push the server cover to the front.
52 Upgrade and Maintenanc e Manual MX130 S2 Basic hardware procedures 4.3 Opening the front cage Figure 7: Opening the front cage Ê Carefully fold open the front cage. I Pay attention to the S A T A data cable, es pecially to the the s limline ODD SA T A data cabl e when you fold open the front cage.
MX130 S2 Upgrade and Maintenance Manual 53 Basic hardware procedures 4.4 Closing the front cage Figure 8: Closing the front cage Ê Carefully close the front cage. V CAUTION! Ensure that none of the cables are strained or trapped! Ê If you loosened any cables tighten them agai n.
54 Upgrade and Maintenanc e Manual MX130 S2 Basic hardware procedures 4.5 Closing the server V CAUTION! ● Before attaching the c overs, make sure no unnecessary p ar ts or tools are left inside the server .
MX130 S2 Upgrade and Maintenance Manual 55 Basic hardware procedures Figure 10: Closing t he server cove r Ê Slide the server cover shut by engaging the loc king mechanism. 4.5.2 Connecting the server to the mains The PRIMERGY MX130 S2 Server is equipped with a st andard PSU .
56 Upgrade and Maintenanc e Manual MX130 S2 Basic hardware procedures Connecting pow er cord Figure 1 1: Connecting power cord Ê Connect the power cord to the power supply .
MX130 S2 Upgrade and Maintenance Manual 57 Basic hardware procedures Only for Japan: Connecting the cable tie Figure 12: Connecting the cable tie Ê Thread the cable tie through the eye (1). Ê Pull the cable tie tight to secure the power cord (2). The insulated connector cannot now be disconnected from th e server accidentall y .
58 Upgrade and Maintenanc e Manual MX130 S2 Basic hardware procedures 4.6 Switching on the server V CAUTION! ● Before switching on the server , make sure the server cover is closed.
MX130 S2 Upgrade and Maintenance Manual 59 5 Basic sof tware procedures 5.1 St arti ng the maintenance t ask 5.1.1 Disabling BitLocker functionality BitLocker Drive Encryption provides protection for operating s ystem and data drives by encrypting the contents and requiring u s ers to authenticate their credentials to access the information.
60 Upgrade and Maintenanc e Manual MX130 S2 Basic sof tware procedures I Administrator permission required: If you are prompted for an administrator password or confirmation, ty pe the pas sword or provide confirmation. Ê T o temporarily disable BitLocker , click T urn Off BitLocker , and then click Disable BitLocker Drive Encryption .
MX130 S2 Upgrade and Maintenance Manual 61 Basic software procedures 5.1.3 V erifying and configuring the bac k up sof tware solution I This task only applies to the Japanese market.
62 Upgrade and Maintenanc e Manual MX130 S2 Basic sof tware procedures 5.2 Completing the m aintenance t ask 5.2.1 Updating th e syst em boa rd BIOS After replacing the sy stem board, it is essential to upgrade the BIOS to the latest version. The latest BIOS versions are available fr om the Fujit su support internet p ages at: http://ts.
MX130 S2 Upgrade and Maintenance Manual 63 Basic software procedures Ê Press the On / Off button to st art up the s erver . The system will detect the USB stick and the BIOS recovery process will be performed. V CAUTION! Do not interrupt the BIOS upgrade process after it has started.
64 Upgrade and Maintenanc e Manual MX130 S2 Basic sof tware procedures 5.2.3 Enabling Option ROM scan In order to configure an expansion card that has been installed or replaced, the card’s Option ROM has to be enabl ed in the sys tem board BIOS. The card’ s firmware is called by the system BIOS upon reboot a nd can be entered and configured.
MX130 S2 Upgrade and Maintenance Manual 65 Basic software procedures I Procedures may differ depending on the backup software. For details, refer to the dedicated documentati on provided separately .
66 Upgrade and Maintenanc e Manual MX130 S2 Basic sof tware procedures 5.2.6 Enabling BitLocker functionality If BitLocker Drive Encryption has been disabled for maint enanc e purposes (see section "Disabling BitLoc k er functionality " on p age 59 ), it has to be re-enabled to complete the service task.
MX130 S2 Upgrade and Maintenance Manual 67 Basic software procedures 5.2.7 Performing a RAID a rray rebuild After replacing a hard di s k drive that has been combined into a R AID array , RAID rebuild will be performed completely unattended as a b ackground process.
68 Upgrade and Maintenanc e Manual MX130 S2 Basic sof tware procedures 5.2.9 Using the Chas sis ID Prom T ool The Chassis ID EPROM located on the system board cont ains system information like server name and model, housing type, serial num ber and manufacturing data.
MX130 S2 Upgrade and Maintenance Manual 69 6 Power supply Basic information The PRIMERGY MX130 S2 server is equipped with a st andard PSU. V CAUTION! The server supports a mains volt age in the range of 100 V - 240 V Y ou may only operate the server if its rated volt age range c orresponds to the local main s volt age.
70 Upgrade and Maintenanc e Manual MX130 S2 Power supply 6.1 St an dar d PS U 6.1.1 Replaci ng the st andard PSU 6.1.1.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Replacing the PSU: – Phillips PH2 / (+ ) No. 2 screw driver 6.
MX130 S2 Upgrade and Maintenance Manual 71 Power supply 6.1.1.3 Disconnecting int ernal power cables Figure 15: Disconnecting int ernal power cables Ê While pressing the release latch (1) on the conn.
72 Upgrade and Maintenanc e Manual MX130 S2 Power supply 6.1.1.4 Removing the PSU Figure 16: Removing the PSU Ê Remove four screws from the PSU (see circles). Ê Slide the defective PSU i nward by 3 cm (1) to disengage the locking mechanism. Ê Lift the defect ive PSU out of the chassis (2).
MX130 S2 Upgrade and Maintenance Manual 73 Power supply 6.1.1.5 Installing the PSU Figure 17: Installing the PSU / 0.
74 Upgrade and Maintenanc e Manual MX130 S2 Power supply Figure 18: Installing t he standard PS U Ê Insert the PSU into the chassis leav ing a gap of about 3 cm to the rear chassi s wall (1) in figure 17 . Ê Ensure that the mounting bracket on the chassis (see circle in figure 18 ) engages with the notch on the lower surface of the PSU.
MX130 S2 Upgrade and Maintenance Manual 75 Power supply Figure 19: Securing the PSU Ê Secure the PSU to the chassis with four screws (M3 x 4.5 mm, s ee circles).
76 Upgrade and Maintenanc e Manual MX130 S2 Power supply 6.1.1.6 Reconnecting intern al power cables Figure 20: Connecting internal power cables Ê Connect the PSU A TX power connector to system board connector POW ER1 2V .
MX130 S2 Upgrade and Maintenance Manual 77 Power supply 6.1.1.7 Concluding steps Perform the following procedures to complete the t ask: Ê Follow all procedures desc ribed in section "Closing the server" on p age 54 .
78 Upgrade and Maintenanc e Manual MX130 S2 Power supply.
MX130 S2 Upgrade and Maintenance Manual 79 7 HDDs and acce ssible drive s Safety notes V CAUTION! ● The HDDs must all be marked c learly so that they can be put back in their original places after an upgrade. If this is not done, existing data can be lost.
80 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives ● Do not touch the circuitry on boards or soldered part s . Hold circuit boards by their metallic areas or edges. ● Circuit boards and soldered p ar ts of i nter nal options are exposed and can be damaged by static electricity .
MX130 S2 Upgrade and Maintenance Manual 81 HDDs and accessible drives ● "Installi ng backup drive in 5.25-inch chassis bay " on page 130 ● "Removing backup drive out of 5.
82 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.2 Mounting order Maximum configuration: 4 x 3.5-inch HDD + slimline ODD Figure 21: Slimline ODD m ounting order with 4 x 3.5-inch HDD Figure 22: Slimline ODD mounting order with 3 x 3.
MX130 S2 Upgrade and Maintenance Manual 83 HDDs and accessible drives 7.3 Inst allin g 3.5-inch HDD in H DD1 / HDD2 chassis bay 7.3.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Install ing a 3.5-inch HDD: tool-less 7.3.2 Preliminary st eps Before installi ng a 3.
84 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.3.3 Inst alling a 3.5-inch HDD in HDD 1/HDD 2 chassis bay Ê Detach and remove the Easy rails from the desired 3.5-inch HDD installation bay . Align the three pi ns on the E asy rails with the s crew holes on the new HDD.
MX130 S2 Upgrade and Maintenance Manual 85 HDDs and accessible drives Figure 25: Inserting the 3.5-inch HDD Ê Insert the HDD into its inst al lation bay .
86 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Figure 26: Instal ling the 3.5-inch HDD Ê Slide the HDD into it s installation bay until the locking latc hes engage.
MX130 S2 Upgrade and Maintenance Manual 87 HDDs and accessible drives Figure 27: Connecting the cables Ê Connect the two SA T A connectors to the HDDs (1 and 2). Ê Plug the cable with the green point to the upper HDD1. For orientation there is a second green point on the other end of thi s cable.
88 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.4 Removing 3.5-inch HDD out of HDD1 / HDD2 ch assis bay 7.4.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Removing a 3.5-inch HDD: tool-less 7.4.2 Prelim inary step s Before removing a 3.
MX130 S2 Upgrade and Maintenance Manual 89 HDDs and accessible drives 7.4.3 Removing a 3.5-inch HDD out of HDD 1/HDD 2 chassis ba y Figure 28: Disconnecting t he cables from the a 3.
90 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Figure 29: Removing a 3.5-inch HDD Ê Pull the two green handles of the Easy rails in the direction of arrow 1. Ê Pull the HDD with the two green handles of the Easy rails completely out of it s bay (2 ).
MX130 S2 Upgrade and Maintenance Manual 91 HDDs and accessible drives 7.4.4 Concluding step s Perform the following procedures to complete the t ask: Ê Close the front cage as described in section "Closing the front cage" on page 53 . Ê Follow all procedures desc ribed in section "Closing the server" on p age 54 .
92 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.5.3 Inst alling an additional 3. 5-inch HDD in 3.5-i nch chas sis b ay Figure 31: Inst alling the HDD in 3.5-inch chassi s bay Ê Insert the HDD into the drive bay and fasten the four screws (see circles).
MX130 S2 Upgrade and Maintenance Manual 93 HDDs and accessible drives Figure 32: Connecting the cables to the HD D Ê Connect cables to the HDD. 1 Power cable connector P3 (see "Power cable T26139-Y4012-V21 1" on page 239 ) 2 SA T A cable T26139-Y4028-V153 7.
94 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.6 Removing additional 3.5-inch HDD out of 3.5-inch chassis bay 7.6.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Install ing a 3.5-inch HDD – Phillips PH2 / (+ ) No.
MX130 S2 Upgrade and Maintenance Manual 95 HDDs and accessible drives 7.6.3 Removing an additional 3.5-inch HDD out of 3.5- inch chassis bay Figure 33: Disconnecting t he cables from the H DD Ê Disonnect cables from the HDD.
96 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Figure 34: Removing the HDD f rom 3.5-inch c hassis bay Ê Remove the four screws (see circles) and remove the HDD from the drive bay .
MX130 S2 Upgrade and Maintenance Manual 97 HDDs and accessible drives 7.7 Inst alling additional 3.5-inch HDD in 5.25- inch dummy cover 7.7.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Install ing a 3.5-inch HDD – Phillip s PH2 / (+) No.
98 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.7.3 Inst alling a 3.5-inch HDD in 5.25 -inch dummy cover Figure 35: Inst alling the HDD in the 5.25-inc h dummy cover Ê Insert the HDD into the 5.25-inch dummy cover (1) and fasten the four screws (2).
MX130 S2 Upgrade and Maintenance Manual 99 HDDs and accessible drives Figure 37: Ins talling t he 5.25-inch dummy cover with HDD into the chassis bay Ê Insert the 5.25-inch dummy cover with HD D in the bay (1) until it snaps into place. Ê Open the front cage as described in se c tion "Opening the front cage" on page 52 .
100 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Ê Connect cables to the HDD. 1 Power cable connector P2 (see "Power cable T26139-Y4012-V21 1" on page 239 ) 2 SA T A cable T26139-Y4028-V153 7.
MX130 S2 Upgrade and Maintenance Manual 101 HDDs and accessible drives 7.8.3 Removing a 3.5-inch HDD out of 5.25-inch dummy cover Figure 39: Disconnecting t he cables from the H DD Ê Disconnect cables from the HDD.
102 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Figure 40: Removing the 5. 25- inch dummy cover with HDD out of the the chassis bay Ê Push the green handle backward (1) and remove the 5.25-inch dummy cover with HDD out of the the bay (2).
MX130 S2 Upgrade and Maintenance Manual 103 HDDs and accessible drives V CAUTION! Always replace dummy modules into u nused drive bays to comply with applicable EMC regulations and sa tisfy c ooling requirements. 7.8.4 Concluding step s Perform the following procedures to complete the t ask: Ê Install the 5.
104 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.9.3 Insta lling an additional 3.5-inch HDD in ODD/HDD bracket Figure 42: Inst alling the HDD in the 5.25-inc h ODD/HDD bracket Ê Insert the HDD into the ODD/HDD bracket (1) and fasten the four screws (2).
MX130 S2 Upgrade and Maintenance Manual 105 HDDs and accessible drives Figure 44: Inserting ODD/HDD brac ket in 5.25-inch chassis bay Ê Insert the ODD/HDD bracket in the bay (1) until it snaps into pl ac e. Ê Open the front cage as described in se c tion "Opening the front cage" on page 52 .
106 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Ê Connect cables to the HDD. 1 Power cable connector P2 (see "Power cable T26139-Y4012-V21 1" on page 239 ) 2 SA T A cable T26139-Y4028-V153 Ê Connect cables to the ODD.
MX130 S2 Upgrade and Maintenance Manual 107 HDDs and accessible drives 7.10.2 Preliminary st ep s Before installi ng a 3.5- inch HDD, perform the following step s: Ê Follow all procedures described i n section "Opening the server" on page 48 .
108 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Ê Disconnect cables to the ODD. 3 Power cable connector P4 (see "Power cable T26139-Y4012-V21 1" on page 239 ) 4 SA T A cable T26139-Y4028-V201 Ê Close the front cage as described in section "Closing the front c age" on page 53 .
MX130 S2 Upgrade and Maintenance Manual 109 HDDs and accessible drives Figure 48: Removing t he fixation plate f rom the 5.25-inch ODD/HDD bracket Ê Remove the fixation plate from the 5.25-inch ODD/HDD bracket. Figure 49: Removing t he HDD out of the 5.
110 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.10.4 Concluding step s Perform the following procedures to complete the t ask: Ê Install the 5.25-inch dummy cover as described in se c tion "Install ing 5.25- inch dummy cover" on page 1 10 .
MX130 S2 Upgrade and Maintenance Manual 111 HDDs and accessible drives 7.1 1.3 Inst alling a 5.25-inch dummy cove r Figure 50: Connecting the fixation pl ate to the 5.25-inch dummy cover Ê Align the four pins of the fixation plate with the screw holes on the 5.
112 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.1 1.4 Concluding step s Perform the following procedures to complete the t ask: Ê Follow all procedures described i n section "Closing the server" on page 54 . 7.12 Removing 5.
MX130 S2 Upgrade and Maintenance Manual 113 HDDs and accessible drives 7.12.3 Removing a 5.25-inch dumm y cover Figure 52: Removing the 5.25-inch dummy cover Ê Push the green handle backward (1) and pull the dummy cover out of it s bay (2).
114 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Figure 53: Removing the fixation plate of the 5.25-inch dummy cover Ê Remove the fixation plate from the dummy c over . V CAUTION! Save the fixation plate for future use. Y ou have to install the fi xation plate to the different driv e c ages before installati on.
MX130 S2 Upgrade and Maintenance Manual 115 HDDs and accessible drives 7.13 Inst alling ODD i n 5.25-inch chassis bay 7.13.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Install ing ODD: tool-less 7.
116 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.13.3 Inst alling an ODD in 5.25-inch c hassis bay Ê Connect the fixation plate to the ODD. Figure 54: Instal ling HH ODD Ê Insert the half-height ODD in the bay (1) until it snap s into place.
MX130 S2 Upgrade and Maintenance Manual 117 HDDs and accessible drives Figure 55: Connecting cables to the HH O DD Ê Connect cables to the HH ODD. 1 Power cable connector P2 (see "Power cable T26139-Y4012-V21 1" on page 239 ) 2 SA T A cable T26139-Y4028-V102 7.
118 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.14 Removing ODD out of 5.25-inch chassis bay 7.14.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Install ing an ODD: tool-less 7.
MX130 S2 Upgrade and Maintenance Manual 119 HDDs and accessible drives 7.14.3 Removing an ODD out of 5.25-inch c hassis bay Figure 56: Disconnecting c ables of the HH ODD Ê Disconnect cables of the HH ODD.
120 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Figure 57: Removing HH ODD Ê Push the green handle backward (1) and pull the half-height ODD out of the bay (2).
MX130 S2 Upgrade and Maintenance Manual 121 HDDs and accessible drives 7.15 Inst alling sliml ine ODD in 5.25-inch ODD/HDD bracket 7.15.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Install i ng a slim line ODD: – EMEA: T orx Plus Size 6 – Japan: Phil ips (+) No.
122 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.15.3 Inst alling a slimline ODD in 5.25-inch ODD/HDD bracket Figure 58: Inst alling the ODD in the 5. 25-inch ODD/HDD bracket Ê Insert the ODD into it s installati on bay and carefully push in until the screw holes are matching.
MX130 S2 Upgrade and Maintenance Manual 123 HDDs and accessible drives Figure 60: Connecting t he fi xation plate to the 5. 25 -inch ODD/HDD bracket Ê Align the four pins of the fixation plate with the screw holes on the 5.25-inch ODD/HDD bracket. Figure 61: Installing the 5.
124 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Ê Open the front cage as described in section "Opening the front cage" on page 52 . Figure 62: Connecting cables of t he slimline ODD in 5.25-inch ODD/HDD bracket Ê Connect cables to the slimline ODD.
MX130 S2 Upgrade and Maintenance Manual 125 HDDs and accessible drives 7.16 Removing slimline ODD out of 5.25- inch ODD/HDD bracket 7.16.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Removing a slimline O DD – EMEA: T orx Plus Size 6 – Japan: Phil ips (+) No.
126 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.16.3 Removing a slimline ODD out of 5.25-inch ODD/HDD bracket Figure 63: Disconnectin g cables of the sl imline ODD in 5.25-inch ODD/HDD bracket Ê Disconnect cables to the sliml i ne ODD.
MX130 S2 Upgrade and Maintenance Manual 127 HDDs and accessible drives Figure 64: Removing the 5. 2 5-inch ODD/HDD bracket with t he slimline ODD Ê Push the green handle backward (1) and pull the 5.
128 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Figure 65: Removing the screws Ê Remove the three screws. Figure 66: Removing the ODD out of the 5.
MX130 S2 Upgrade and Maintenance Manual 129 HDDs and accessible drives Figure 67: Removing t he fixation plate of the 5.25-inch ODD/HDD bracket Ê Remove the fixation plate from the 5.25-inch ODD/HDD bracket. 7.16.4 Concluding step s Perform the following procedures to complete the t ask: Ê Install the 5.
130 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.17 Inst alling backup drive in 5.25-inch chassis bay 7.17.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Removing accessible drives: tool-l ess 7.
MX130 S2 Upgrade and Maintenance Manual 131 HDDs and accessible drives 7.17.3 Inst alling a backup driv e in 5.25- inch chassis bay Figure 68: Connecting the fixation pl a te to the 5. 25 -inch chassis bay Ê Align the four pins of the fixation plate with the screw holes on the 5.
132 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Figure 70: Connecting cables to the backup drive Ê Connect cables to the backup drive.
MX130 S2 Upgrade and Maintenance Manual 133 HDDs and accessible drives 7.18 Removing backup drive out of 5.25-inch chassis bay 7.18.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Removing a backup drive: tool-less 7.
134 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.18.3 Removing backup drive out of 5 .25-inch chas sis bay Figure 71: Disconnect ing cabl es from the bac kup drive Ê Disconnect all cables from the backup drive. Ê Disconnect cables from the backup drive.
MX130 S2 Upgrade and Maintenance Manual 135 HDDs and accessible drives Figure 72: Removing the backup drive Ê Push the green handle backward (1) and pull the backup drive out of it s bay (2). V CAUTION! Always replace dummy modules into u nused drive bays to comply with applicable EMC regulations and sa tisfy c ooling requirements.
136 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.19 Inst alling slim line ODD in slimline chassis bay 7.19.1 Required tools ● Preliminary and concludi ng s teps : – Slotted screw driver (only for removing the ODD filler cover) ● Install ing accessible drives: tool-less 7.
MX130 S2 Upgrade and Maintenance Manual 137 HDDs and accessible drives 7.19.3 Removing the ODD filler c over Figure 73: Removing the ODD fill er cover Ê Using a slotted screw driver , pry the ODD filler cover out of its bay and remove it from its installation bay .
138 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.19.4 Inst alling the ODD Figure 74: Instal ling the ODD Ê Attach the inst allation bracket to the ODD as shown.
MX130 S2 Upgrade and Maintenance Manual 139 HDDs and accessible drives Figure 75: Installing the ODD Ê Ensure that the hooks on the inst allation bracket properly engage with the screw holes on the ODD (see circles). Figure 76: Installing the ODD Ê Insert the ODD in the bay until it s naps into place.
140 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Ê Open the front cage as described in section "Opening the front cage" on page 52 .
MX130 S2 Upgrade and Maintenance Manual 141 HDDs and accessible drives Figure 78: Removing the ODD cover Ê Press the ODD cover out from inside to outside of the server cover .
142 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives 7.20 Replacing slim line ODD out of slimline chassis bay 7.20.1 Required tools ● Preliminary and concludi ng s teps : ● Removing accessible drives: tool -less 7.
MX130 S2 Upgrade and Maintenance Manual 143 HDDs and accessible drives 7.20.3 Replacing a slimline ODD out of slimline chassis bay Figure 79: Disconnecting c ables from the ODD Ê Disconnect all cables from the ODD.
144 Upgrade and Maintenanc e Manual MX130 S2 HDDs and accessible drives Figure 80: Removing the ODD Ê Press the green locking (1) and pull the ODD out of it s bay (2).
MX130 S2 Upgrade and Maintenance Manual 145 8 System fan Basic information The PRIMERGY MX130 S2 server features one system fan module. I Additional fans in PSU and processor heat sink cannot be replaced individually . V CAUTION! Since the system fan is not redundant is has to be replaced immediately in case of defects or pre-failure events.
146 Upgrade and Maintenanc e Manual MX130 S2 System fan 8.1 Replacing the system fan module 8.1.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Replacing the fan module: – Side cutter / pincer 8.
MX130 S2 Upgrade and Maintenance Manual 147 System fan 8.1.3 Removing the system fan module Figure 81: Disconnecting t he cable of the system fan module Ê Disconnect the fan cable from system board connector F AN2.
148 Upgrade and Maintenanc e Manual MX130 S2 System fan Figure 82: Cutting the f r ont fan rivet s Ê T ear the front fan rivets a little out and cut them with a s i de cutter .
MX130 S2 Upgrade and Maintenance Manual 149 System fan Figure 83: Removing the system fan module Ê Pull the fan cable out of the chassis. Ê T ake the sys tem fan module out from the c hassis.
150 Upgrade and Maintenanc e Manual MX130 S2 System fan 8.1.4 Inst alling the sys tem fan module Figure 84: Fitting the new system fan module with new front fan r ivet s Ê Fit four new front fan rivets into the fan.
MX130 S2 Upgrade and Maintenance Manual 151 System fan Figure 85: System fan with installed fan rivets Ê The front system fan has four fan rivets A, B, C and D (see circles).
152 Upgrade and Maintenanc e Manual MX130 S2 System fan Figure 86: Installing t he sys tem fan module Ê Insert the system fan module into the chass is. Figure 87: Fitting front fa n rivets Ê Put the two front fan rivets A and B into the fan slots in the chassis with the help of a pincer (see circles).
MX130 S2 Upgrade and Maintenance Manual 153 System fan Figure 88: Position of f ront fan rivets A and B Ê Make sure that both front fan rivets A and B fit the hol es in the chassis fan slots ( see cir cles) .
154 Upgrade and Maintenanc e Manual MX130 S2 System fan Figure 90: Fitting front fa n rivet C Ê Use a pincer to fit front fan rivet C in the hole in the chassis fan s lot (see circle ). Figure 91: Fitting front fa n rivet D Ê Use a pincer to fit front fan rivet D in the hole in the chassis fan s lot (see circle ).
MX130 S2 Upgrade and Maintenance Manual 155 System fan Figure 92: Position of the front fan rivets in the chassis fan slots Ê Make sure that all front fan rivets match the holes in the c hassis fan slots (see circ les).
156 Upgrade and Maintenanc e Manual MX130 S2 System fan Figure 94: Final position of a front fan rivet in t he chass is fan slot Ê T ear out the front fan rivets a little bit. Figure 95: Cutting the overlaying p art of the front fan rivets Ê Cut the overlaying part of the front fan rivet s (1) with the side cutter (2).
MX130 S2 Upgrade and Maintenance Manual 157 System fan Figure 96: Connecting the system fan cable Ê Connect the fan cable to system board connector F AN2. 8.1.5 Concluding step s Ê Follow all procedures desc ribed in section "Closing the server" on p age 54 .
158 Upgrade and Maintenanc e Manual MX130 S2 System fan.
MX130 S2 Upgrade and Maintenance Manual 159 9 Exp an sion cards This chapter provides information on how to install , remov e or replace expansion cards. Safety notes V CAUTION! ● Do not damage or modify internal cables or devices. Doing so m ay cause a device failure, fire, or electric shock.
160 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards 9.1 Basic procedure The system board is equipped with four exp ansion slots: Figure 97: PCI slot overview Sl ot se quen ce PCI slot T ype .
MX130 S2 Upgrade and Maintenance Manual 161 Expansion cards 9.2 Exp ansion cards 9.2.1 Inst alling exp ansion cards 9.2.1.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Install ing expansion cards: tool-less 9.
162 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards 9.2.1.3 Removing a PCI slot bracket Figure 98: Opening the PCI slot bracket c lamp Ê Fold up the slot bracket clamp.
MX130 S2 Upgrade and Maintenance Manual 163 Expansion cards Figure 99: Removing the PCI slot bracket Ê Remove the slot bracket. V CAUTION! Keep the slot bracket for further use. Always replace slot brackets i nto unused PCI slot openings to comply with applicable EMC regulations and satisfy cooling requirement s.
164 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards Figure 100: Instal ling the expansion card Ê Carefully insert the expansion card into the desired PCI slot and pr ess down firmly until it is fully seated in the slot. Ê Fold down slot bracket clamp until it locks in place.
MX130 S2 Upgrade and Maintenance Manual 165 Expansion cards 9.2.1.5 Connecting cables t o the exp ansion card Ê If applicable, connect in ter nal cables to the exp ans ion card. I For a complete cabling overview , please refer to section "Cabling" on page 235 .
166 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards 9.2.2.2 Preliminary step s Before removing an expansion card, perform the foll owing steps: Ê Disable BitLocker functionality as descri bed in section "Disabling BitLocker functionality" on p age 59 .
MX130 S2 Upgrade and Maintenance Manual 167 Expansion cards 9.2.2.4 Installing a PCI slot bracket V CAUTION! Always replace slot brackets into unused PCI slot openings to c omply with applicable EM C regulations and satisfy cooling requirement s.
168 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards 9.2.3 Inst alling eSA T A cable 9.2.3.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Install ing expansion cards: tool-les s 9.
MX130 S2 Upgrade and Maintenance Manual 169 Expansion cards Figure 103: Installing the eS A T A cable Ê Carefully insert the eSA T A cable into the desired PCI s lot and press down firmly until it is fully seated in the slot. Ê Fold down slot bracket clamp until it lock s in place.
170 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards 9.2.3.4 Connecting cable o f the eSA T A cable to connector Figure 104: Connecting the eSA T A cable Ê Connect the end of eSA T A cable to the syst em board connector SA T A6. Ê Fold the cable carefully as shown in the picture.
MX130 S2 Upgrade and Maintenance Manual 171 Expansion cards 9.2.4.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Removing expansion cards: tool-less 9.
172 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards 9.2.4.4 Removing an eSA T A cable Figure 106: Removing an eSA T A cable Ê Fold up the locking han dle on the slot bracket clamp. Ê Carefully remove the eSA T A c able from it s slot. 9.2.
MX130 S2 Upgrade and Maintenance Manual 173 Expansion cards 9.3 Additional t asks This section provides additional exp ansion card related information on how to install s l ot brackets.
174 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards 9.3.1.2 Network adapter D2907 Figure 107: Network adapter D2907 - Mounting the slot bracket (A) Ê Place the controller on the mounting t abs on the slot bracket (1).
MX130 S2 Upgrade and Maintenance Manual 175 Expansion cards Figure 108: Network adapt er D2907 - M ounting the slot bracket (B ) Ê Secure the slot bracket to the controller with two M3 x 4.5 mm screws. Figure 109: Network adapt er D2907 - M ounting the slot bracket (C ) I Assembled network adapter D2907.
176 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards 9.3.1.3 Network adapter D2745 Figure 1 10: Network adapter D2745 - Mounting the slot bracket (A) Ê Hinge the slot bracket to the plug shell as shown (1).
MX130 S2 Upgrade and Maintenance Manual 177 Expansion cards Figure 1 1 1: Network adapter D2745 - Mounting t he slot bracket (B) Ê Secure the slot bracket to the controller with one M3 x 4.
178 Upgrade and Maintenanc e Manual MX130 S2 Exp ansion cards.
MX130 S2 Upgrade and Maintenance Manual 179 10 Main m emory Safety notes V CAUTION! ● Do not install unsupported third party memory modules. For further information on supported memory modules, refer to section "Basic procedure" on page 180 .
180 Upgrade and Maintenanc e Manual MX130 S2 Main memory 10.1 Basic procedure – The system board is equipped with four memory connectors. – The system has to be equipped with at least one memo r y module.
MX130 S2 Upgrade and Maintenance Manual 181 Main memory 10.1.2 Operation modes – The maximum performance can be achieved in a symmetric dual-channel configuration. Therefore both channels have to be populated with the sa me amount of memory . The DRAM device technology (1 Gbit / 2 Gbit / 4 Gbit) may vary from one channel to the other .
182 Upgrade and Maintenanc e Manual MX130 S2 Main memory 10.2 In st alling memory m odules 10.2.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Install ing memory modules: tool-less 10.
MX130 S2 Upgrade and Maintenance Manual 183 Main memory Figure 1 15: Installing memory modules (B) Ê Align the notch on the bottom of the modu le with the crossbar in the connector . Ê Press down on the memory module until the securing clip s snap into the cutouts at each end of the modul e.
184 Upgrade and Maintenanc e Manual MX130 S2 Main memory 10.3 Removing memory m odules 10.3.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Removing memory modules: tool-les s 10.
MX130 S2 Upgrade and Maintenance Manual 185 Main memory Figure 1 16: Removing memory modules Ê Eject the desired memory module by pressing out the securing clips at each end of the memory module connector .
186 Upgrade and Maintenanc e Manual MX130 S2 Main memory.
MX130 S2 Upgrade and Maintenance Manual 187 1 1 Processor s Safety notes V CAUTION! ● Do not install unsupported processors. For further information on supported processors, refer to s ection "Basic procedure" on page 188 . ● Circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity .
188 Upgrade and Maintenanc e Manual MX130 S2 Processors 1 1.1 Basic procedure Supported processors – AMD FX, AMD Sempron, Athlon II, Phenom II – Socket type: AM3+ – Thermal Design Power (TDP) class: 95W 1 1.2 Replacing the processor heat sink 1 1.
MX130 S2 Upgrade and Maintenance Manual 189 Processors 1 1.2.3 Removing the processor heat sink Figure 1 17: Removing the processor heat s ink Ê Loosen the four captive screws on the heat sink in a crossover pattern. Ê Disconnect the CPU fan cable from the system board connector F A N1.
190 Upgrade and Maintenanc e Manual MX130 S2 Processors 1 1.2.4 Thermal p aste I On a new CPU heat sink a thin layer of thermal compound has already been pre-applied to its lower surface. This layer of thermal compound is protected by a cover . Ê Remove the cover at the lower surface of the new heat sink.
MX130 S2 Upgrade and Maintenance Manual 191 Processors Ê Fasten the four captive screws on the heat sink (screw torque: 0.6 Nm, not applicable for the Japanese market).
192 Upgrade and Maintenanc e Manual MX130 S2 Processors 1 1.3.2 Preliminary steps Before upgrading or replacing the processor , per form the following steps: Ê Disable BitLocker functionality as descri bed in section "Disabling BitLocker functionality" on p age 59 .
MX130 S2 Upgrade and Maintenance Manual 193 Processors Figure 120: Removing the processor Ê Carefully remove the defective processor from its socket in a vertical motion.
194 Upgrade and Maintenanc e Manual MX130 S2 Processors 1 1.3.5 Insta lling the processor Figure 121: Installing t he proces sor Ê Hold the processor with your thumb and index finger . Make sure that the indication triangle on the processor al igns with the notch on the socket.
MX130 S2 Upgrade and Maintenance Manual 195 Processors Figure 122: Latching the socket lever Ê Latch the socket lever ..
196 Upgrade and Maintenanc e Manual MX130 S2 Processors 1 1.3.6 Applying thermal p aste I For the Japanese market, follow the instructions provided separately . I If the processor upgrade or replacement kit contains a new CPU heat sink, a thin layer of thermal compound has al ready been pre-applied to its lower surface.
MX130 S2 Upgrade and Maintenance Manual 197 Processors Figure 124: Applying therm al paste Ê Apply a small streak of thermal p as te (1.0 gram, see description above) to the center of the processor surface as shown. V CAUTION! Do not mix dif fer ent types of thermal p aste.
198 Upgrade and Maintenanc e Manual MX130 S2 Processors.
MX130 S2 Upgrade and Maintenance Manual 199 12 System bo ard and compone nt s This chapter provides information on how to replace the system board and system board components as its CMOS battery and the T rusted Platform Module (TPM). Safety notes V CAUTION! ● Devices and components inside the server remain hot af ter shutdown.
200 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s 12.1 Replacing the CMOS battery CMOS memory (volatile BIOS memory) and the real-time clock are powered by a lithium coin cell (CMOS battery). This cell last s two to ten years, depending on ambient temperature and use.
MX130 S2 Upgrade and Maintenance Manual 201 System board and comp onents 12.1.2 Preliminary step s Before replacing the CMOS battery , perform the following steps: Ê Follow all procedures described i n section "Opening the server" on page 48 .
202 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s Ê Carefully pry the depleted CMOS battery out of its s ocket. Ê Remove the CMOS battery (2). I Do not throw the CMOS battery into the trash can. Lithium batteries must be disposed of in accordanc e with l ocal regulations concerning special waste.
MX130 S2 Upgrade and Maintenance Manual 203 System board and comp onents This information does not apply to the Jap anese market. Do not throw lithium batteries into the trash can. They must be disposed of in accordance with local r egulations concerning s pecial waste.
204 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s 12.2 T rusted Plat form Module (TPM) This section provides information on how to inst all, remove or replace the T rusted Platform Module (TPM). 12.2.1 Inst alling the TPM board 12.
MX130 S2 Upgrade and Maintenance Manual 205 System board and comp onents 12.2.1.3 Installing the TPM board Figure 127: TPM kit TPM kit (S26361-F3299-E2): 1 TPM module S26361-D2727-A10 2 TPM spacers I Use the white TPM spacer (A3C40106008). The black TPM spacer is not used i n this server .
206 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s Figure 128: TPM m ounting location (detail) TPM mounting location on the system board: 1 Cut-out for TPM spacer 2 TPM connector Figure 129: Installing t he T PM spacer Ê Snap the TPM spacer into the c ut- out in the system board.
MX130 S2 Upgrade and Maintenance Manual 207 System board and comp onents Figure 130: Installing the TPM boar d Ê Connect the new TPM board to the system board. Figure 131: TPM bit insert Ê Attach the T PM bit insert or TPM m odule fix ing tool (Japanese market) to a bit screw driver .
208 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s Figure 132: Securing the TPM board Ê Secure the TPM board with the TPM special s crew using the TPM bit insert. I Do not fasten the screw too firmly . S top as soon as the head of the screw lightly touches the TPM board.
MX130 S2 Upgrade and Maintenance Manual 209 System board and comp onents I For detailed inform ation on how to access the BIOS and modify settings, refer to the "Description - BIOS Manual D3090 / D3091" available online at http://manuals.ts.
210 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s 12.2.2.2 Preliminary steps Before removing the TPM board, perform the following step s : Ê Before removing the TPM board, it is necessary to remove BitLocker- protection from the computer and to decrypt the volume.
MX130 S2 Upgrade and Maintenance Manual 211 System board and comp onents Ê Follow all procedures described i n section "Opening the server" on page 48 . 12.2.2.3 Removing the TPM bo ard Ê Remove the system board as described in s ection "Removing the system board" on page 215 .
212 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s Ê Carefully loosen the TPM screw using a thin slotted screw driver (e.g. watchmaker's screw driver) or the dedicated TPM screw driver (Japanese market) (2).
MX130 S2 Upgrade and Maintenance Manual 213 System board and comp onents 12.3 Replacing the system board 12.3.1 Required tools Note on TPM I The system board can be equipped with an optional TPM (T rusted Platform Module). This module enables third p arty programs to store key information (e.
214 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s ● Replacing the system board: – Phillips PH2 / (+ ) No. 2 screw driver ● Replacing the system board: – Magnifying gla.
MX130 S2 Upgrade and Maintenance Manual 215 System board and comp onents 12.3. 3 Removi ng the sy stem boa rd Ê Remove all cables from the system board.
216 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s Ê Remove eight screws from the system board (see circles) beginni ng with the two centering bolt s (C).
MX130 S2 Upgrade and Maintenance Manual 217 System board and comp onents Figure 137: Removing the heat sink co unter plate Ê Remove heat sink counter plate from the bottom side of the system board.
218 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s 12.3.4 Inst alling the system board 12.3.4.1 Mounting the system board Figure 138: Inserting t he heat sink count er plate Ê Insert the heat sink counter plate from the bottom to the system board.
MX130 S2 Upgrade and Maintenance Manual 219 System board and comp onents Figure 139: Installing the sy stem board (A) Ê Hold the new system board by the memory module ejectors and a PCI slot.
220 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s Figure 140: Installing t he sys tem board (B) Ê Secure the system board with eight screws (M3 x 4.5 mm, standard C67 screw) (see circles) beginning with the two centering bolts (C).
MX130 S2 Upgrade and Maintenance Manual 221 System board and comp onents 12.3.5 Concluding step s Ê Reconnect all cables to the system board. For a complete cabling overview , please refer to section "Cabling" on page 235 .
222 Upgrade and Maintenanc e Manual MX130 S2 System board and compo nent s.
MX130 S2 Upgrade and Maintenance Manual 223 13 Front p anel and front USB Safety notes V CAUTION! ● When inserting the front panel module i nto the ser ver , ens ure not to pinch or strain any connected cables. ● Circuit boards and soldered parts of internal options are exposed and can be damaged by static electricity .
224 Upgrade and Maintenanc e Manual MX130 S2 Front panel and front US B 13.1 Replacing the front p anel ind icators The On/Off button and the HDD activity LED are part of the front panel module. 13.1.1 Required tools ● Preliminary and concludi ng steps: tool-less ● Replacing the front p anel module: tool-less 13.
MX130 S2 Upgrade and Maintenance Manual 225 Front panel an d front USB 13.1.3 Removing the On/Off button Figure 141: Removing the On/Off but t on Ê Press the two retaining clip s together and push the On/Off button bac kwards in the chassis. I Note the orientation of the On/Of f button.
226 Upgrade and Maintenanc e Manual MX130 S2 Front panel and front US B 13.1.4 Removing the HDD ac tivity LED Figure 142: Removing the HDD activity LED Ê Push apart the two latches (1) and pull the LED to the di r ection of the arrow (2).
MX130 S2 Upgrade and Maintenance Manual 227 Front panel an d front USB 13.1.5 Removing the cable for On/Off button and HDD acti vity LED Figure 143: Disconnecting f ront panel cable Ê Remove the cable from the cable holder(1). Ê Disconnect the cable from system board connector Front panel (2).
228 Upgrade and Maintenanc e Manual MX130 S2 Front panel and front US B 13.1.6 Installing the On/Off button and the HDD activity LED Figure 144: Instal ling the On/Off bu tton and HDD activity LE D Ê Insert the HDD activity LED in the di rection shown until it snaps in place (1).
MX130 S2 Upgrade and Maintenance Manual 229 Front panel an d front USB 13.2 Replacing the front USB board 13.2.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Replacing the front panel module: – Phillip s PH2 / (+) No. 2 screw driver 13.
230 Upgrade and Maintenanc e Manual MX130 S2 Front panel and front US B 13.2.3 Removing the defective front USB board Figure 145: Disconnecting the USB front cable, removing the front U SB board Ê Disconnect the front USB cable from the front USB board (1).
MX130 S2 Upgrade and Maintenance Manual 231 Front panel an d front USB 13.2.4 Inst alling the new front USB board Figure 146: Installing the front USB board Ê Insert the new front USB board.
232 Upgrade and Maintenanc e Manual MX130 S2 Front panel and front US B Figure 147: Connecting the USB front c able Ê Secure the new front USB board with two screws (1) Ê Connect the front USB cable to the front USB board (2). 13.2.5 Concluding steps Ê Close the front cage as described in section "Closing the front c age" on page 53 .
MX130 S2 Upgrade and Maintenance Manual 233 14 Cables Safety notes V CAUTION! ● Always hold cables by their connectors when disconnecting them. Never pull on the cable to disconnect cables. ● Ensure that none of the cables are scraped, strained or otherwise damaged while replacing system component s.
234 Upgrade and Maintenanc e Manual MX130 S2 Cables 14.1 Cabling overview 14.1.1 Overview of used cables # Nam e Numb er Rout ing 1 Front panel connector cable T26139-Y4001- V21 1 from front LEDs to s.
MX130 S2 Upgrade and Maintenance Manual 235 Cables 14.2 Cabling 14.2.1 Power cabling St andard configu ration Figure 148: Power cabling Battery PCI SA TA 3+4 SA TA 5+6 Power Supply PCI-E x16 PCI-E x4 .
236 Upgrade and Maintenanc e Manual MX130 S2 Cables Configuratio n with RDX Figure 149: Power cabling - RDX drive Battery PCI SA TA 3+4 SA TA 5+6 Power Supply PCI-E x16 PCI-E x4 PCI-Ex1 Northbridge AM.
MX130 S2 Upgrade and Maintenance Manual 237 Cables 14.2.2 Dat a cabling Dat a cabling fixed positions Figure 150: Data cabling for RDX, eSat a and Dash LAN Battery PCI SA TA 3+4 SA TA 5+6 Power Supply.
238 Upgrade and Maintenanc e Manual MX130 S2 Cables Dat a cabling variable positions d epending on the d rive configuration Figure 151: Data cabling with slim ODD via chassis- adapter SA T A- Port HDD.
MX130 S2 Upgrade and Maintenance Manual 239 Cables 14.3 Replacing the power cable Figure 152: Power cable T26139-Y4012-V21 1 14.3.1 Required tools ● Preliminary and concludi ng step s: tool-less ● Replacing the power cable: tool-less 14.
240 Upgrade and Maintenanc e Manual MX130 S2 Cables 14.3.3 Removing the power cable Figure 153: Detaching t he power cable Ê While pressing the release latch on the connector (1), disconnect the power cable from the POWER SA T A connector on the system board (2).
MX130 S2 Upgrade and Maintenance Manual 241 Cables Figure 154: Disconnecting t he power cable from installed drives Ê Disconnect all power cable connectors from the insta lled drives (1). It depends on your configuration which drives are installed. For detail s refer to section "HDDs and accessible drives" on page 79 .
242 Upgrade and Maintenanc e Manual MX130 S2 Cables 14.3.4 Inst alling the power cable Figure 155: Connecting the power cable to t he sys tem board Ê Connect the new power cable to system board connector POW ER SA T A (1 ). Ê Run the power cable through the five cable clamps (see circles).
MX130 S2 Upgrade and Maintenance Manual 243 Cables Figure 156: Connecting th e power cable Ê Connect all power cable connectors to the instal led drives (1). It depends on your configuration which drives are installed. For detail s refer to section "HDDs and accessible drives" on page 79 .
244 Upgrade and Maintenanc e Manual MX130 S2 Cables.
MX130 S2 Upgrade and Maintenance Manual 245 15 Append ix 15.1 Mechanical overview 15.1.1 Server front Figure 157: PRI MERGY MX130 S 2 front Pos. Component 1 5.
246 Upgrade and Maintenanc e Manual MX130 S2 Appe ndix 15.1.2 Server re ar Figure 158: PRIMERG Y MX130 S2 rear Pos. Comp onent 1 Main power 2 PS2 connector (for mouse) 3 Serial connector (COM1) 4 S ta.
MX130 S2 Upgrade and Maintenance Manual 247 Appendix 15.1.3 Server interi or Figure 159: PRIMER GY MX130 S2 interior Pos. Component 1 System board D3090 2 S tandard PSU 3 ON/OFF button, HDD activity i.
248 Upgrade and Maintenanc e Manual MX130 S2 Appe ndix 15.2 Configuration t a bles 15.2.1 Mounting order for HDDs Please refer to chapter "HDDs and accessible drives" on page 79 . 15.2.2 Memory board configuration Please refer to chapter "Main memory" on page 179 .
MX130 S2 Upgrade and Maintenance Manual 249 Appendix 15.3 Connectors and indicators 15.3.1 Conn ectors and indi cators on the system board 15.3.1.1 Onboard conn ectors Figure 160: Internal con nectors of the system board D3090 No.
250 Upgrade and Maintenanc e Manual MX130 S2 Appe ndix 15.3.1.2 Onboard settings Figure 161: Jumper 9 USB-FRONT 3/4 USB connector for accessible backup drive 10 Dash USB 5/6 USB connector for Dash LAN cable Setting Description Default Password skip disabled and recovery BIOS disabled.
MX130 S2 Upgrade and Maintenance Manual 251 Appendix 15.3.1.3 I/O panel connectors Figure 162: Connect or panel on the rear side 1 PS2 connector (for mouse) 2 Serial connector (COM1) 3 S tandard LA N .
252 Upgrade and Maintenanc e Manual MX130 S2 Appe ndix 15.3.1.4 I/O panel indicators Figure 163: Indicators on the connector panel: LAN indicators I Note on the onb oard LAN controller The system board is equipped with a Gigabit Ethernet Controller that supports transfer rates of 10 Mbit/s, 100 Mbit/s and 1 Gbit/s.
MX130 S2 Upgrade and Maintenance Manual 253 Appendix 15.3.2 Conn ectors and indi cators on the front p anel Figure 164: Front s ide (indicators and cont rols) St atus indicators 1 HDD activity indicator 3 2 USB connectors 2 On/Off button - Power-on indicator Pos.
254 Upgrade and Maintenanc e Manual MX130 S2 Appe ndix Buttons 15.4 Minimum sta rtup co nfiguratio n If the server does not start up or other problems occur , it may be necessary to take the s ystem down to its most bas ic configuration in order to isolate the defective component.
MX130 S2 Upgrade and Maintenance Manual 255 Appendix Ê Follow all procedures described i n section "Opening the server" on page 48 . Ê T ake the system down to its minimum st artup configuration. Ê Connect a keyboard, mouse and display to the server .
256 Upgrade and Maintenanc e Manual MX130 S2 Appe ndix.
Ein wichtiger Punkt beim Kauf des Geräts Fujitsu MX130 S2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Fujitsu MX130 S2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Fujitsu MX130 S2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Fujitsu MX130 S2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Fujitsu MX130 S2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Fujitsu MX130 S2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Fujitsu MX130 S2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Fujitsu MX130 S2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Fujitsu MX130 S2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.