SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type CONTENTS SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . 1 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . 2 REFRIGERANT SYSTEM DIAGRAM . . . . 4 CIRCUIT DIAGRAM . . . . . . . . . . . .
1 2006.01.31 SPECIFICATIONS INDOOR UNIT ASU30CLX ASU36CLX OUTDOOR UNIT AOU30CLX AOU36CLX COOLING CAPACITY 30,700 BTU/hr 33,100 BTU/hr POWER SOURCE 208 V / 230 V 208 V / 230 V FREQUENCY 60 Hz 60 Hz RUNNING CURRENT 15.2 A 17.7 A INPUT WATTS 3,460 W 4,040 W SEER 15.
2006.01.31 OUTLINE AND DIMENSIONS Unit : inch (mm) INDOOR UNIT Model : ASU30CLX, ASU36CLX 2 39-1/4" (998) 9" (228) 12-5/8" (320).
Unit : inch (mm) OUTDOOR UNIT Models : AOU30CLX, AOU36CLX 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 2006.
REFRIGERANT SYSTEM DIAGRAM 3-Way valve (Small) 3-Way valve (Large) Strainer Strainer Muffler Pressure switch 4-Way valve Expansion valve Heat exchanger ( INDOOR ) Heat exchanger ( OUTDOOR ) Sub-accumulator Compressor Cooling ASU30CLX / AOU30CLX ASU36CLX / AOU36CLX Models : Refrigerant pipe diameter Liquid : 3/8" (9.
CIRCUIT DIAGRAM 2006.01.31 5.
CN1 1 B07B-9ASK CN201 JB20-07HG CN1 1-1 RED CN1 1-2 WHITE CN1 1-3 WHITE CN1 1-4 WHITE CN1 1-6 WHITE CN1 1-7 WHITE CN1 1-5 WHITE 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 .
5V V A6 470V <TNR> R106 1.0K </2W>8 TM2 (3) D14 DAN202K Q1 1 DTC124EUA 1 2 3 3 2 1 2 3 1 Q10 DTC124EUA C54 0.01 <B> R1 14 390 <1/10W> 10 5 4 3 2 1 14 18 8 27 6 5 4 I C26-14 I C26-10 3 2 1 I C1-6 I C1-47 I C1-46 R105 10K <1/10W> 5V C50 0.
CN201 5V C201 0.1 <F> 5V + C202 47/ 10V R201 47 <1/4W> I C201 GP1UM261R 5V D201 SLR-325 D203 SLR-325 D202 SLR-325 5 4 6 1 2 3 7 2 1 3 VCC OUT GND INDICA TOR PCB ASSY K05CY -0500HSE-D0 Models : ASU30CLX ASU36CLX 2006.
TR PCB ASSY ( I P M ) K05CZ-0503HUE-TR0 CAP ACITOR PCB ASSY K05FB-0500HUE-P0 ACTPM CONTROLLER PCB ASSY AOU30CLX : K05CU-0503HUE-C1 AOU36CLX : K05CU-0504HUE-C1 POWER SUPPL Y PCB ASSY K05CW-0503HUE-FL0 INVERTER ASSEMBL Y AOU30CLX : EZ-00502HUE AOU36CLX : EZ-00503HUE Models : AOU30CLX AOU36CLX 2006.
C64 10K <1/10W> C64 10K <1/10W> 2006.02.10 CONTROLLER PCB ASSY AOU30CLX : K05CU-0503HUE-C1 AOU36CLX : K05CU-0504HUE-C1 Models : AOU30CLX AOU36CLX 10.
2006.02.10 TR PCB ASSY ( I P M ) K05CZ-0503HUE-TR0 Models : AOU30CLX AOU36CLX 11.
POWER SUPPL Y PCB K05CW-0503HUE-FL0 2006.02.10 Models : AOU30CLX AOU36CLX 12.
B B W13 VIOLET W12 WHITE R200 220K <2W> C200 C201 C202 C203 + + + + 660 / 450V x 4 SMOOTHING CIRCUIT B B W8 BLUE W7 YELLOW 2006.02.10 CAP ACIT OR PCB ASSEMBL Y K05FB-0500HUE-P0 Models : AOU30CLX.
ERROR CONTENTS Error Operation LED Timer LED Serial signal error Normal 2 flash 3 flash 4 flash 5 flash Serial signal (reverse) error, at operation start up Serial signal (reverse) error, during oerat.
4 2 2 4 6 1 5 5 2006.02.10 15 DISASSEMBLY ILLUSTRATION Models : ASU30CLX , ASU36CLX.
2006.02.0 7 16 Models : ASU30CLX, ASU36CLX 33 29 30 8 9 31 27 28 35 36 34 28 32.
10 10 10 10 10 10 10 10 10 10 10 10 26 10 23 22 10 Models : ASU30CLX, ASU36CLX 2006.02.10 17.
2006.02.07 Models : ASU30CLX, ASU36CLX 18.
2006.02.07 19 Models : AOU30CLX AOU36CLX.
2006.02.02 20.
2006.02.07 21.
2006.02.07 22.
2006.02.07 23 When you order parts, please make a photocopy of this page and fill the number of the parts in the "Order" column. INDOOR UNIT PARTS LIST Ref.
OUTDOOR UNIT Ref. Ord. No. AOU30CLX AOU36CLX Q'ty 1 TOP PANEL SUB ASSY 9374417032 9374417032 2 FRONT PANEL M 9374094066 9374094066 3 FAN GUARD 9374330010 9374330010 4 GRIP SIDE 9374173013 9374173.
9305642045 Remote control unit holder Name and Shape Part No. 9315023018 9315027160 0600185534 0700076046 9310519004 9312153060 9311925071 Remote control unit Battery (penlight) Cloth tape Tapping screw (big) Wall hook bracket STANDARD ACCESSORIES 9301102000 Tapping screw (small) 0700019036 Air cleaning filter Air cleaning filter frame 2006.
0512G2975.
Ein wichtiger Punkt beim Kauf des Geräts Fujitsu AOU30CLX (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Fujitsu AOU30CLX noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Fujitsu AOU30CLX - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Fujitsu AOU30CLX reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Fujitsu AOU30CLX erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Fujitsu AOU30CLX besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Fujitsu AOU30CLX verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Fujitsu AOU30CLX. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Fujitsu AOU30CLX gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.