Benutzeranleitung / Produktwartung M3000 des Produzenten Frymaster
Zur Seite of 50
LOV LOV ™ FRYER Generation II FRYER Generation II TECHNICAL REFERENCE MANUAL TECHNICAL REFERENCE MANUAL FEB 2010 Edition Introducing the LOV ™ Fryer 1 The LOV ™ Systems 2 M3000 12 RTI-equipped S.
LOV ™ Generation II T echnical Reference 1 The Low Oil V olume (LOV ™ ) fryer is a McDonald’ s-only , feature-laden version of the electric RE fryer or gas H55 fryer . The enhancements found on the LOV ™ fryer include: • Low volume frypot — 30 pounds (15 liters) rather than 50 pounds (25 liters) of oil.
LOV ™ Generation II T echnical Reference 2 Auto T op Off The core of the system is the automatic top-off board, which senses when the oil level is low and fi lls the pot to the top line. The oil level is monitored by an R TD ( R esistance T emperature D etector) sensor in the frypot at the upper oil level.
LOV ™ Generation II T echnical Reference 3 The A T O board is positioned under the LON gateway in a box with a transformer that provides power to the board. The LON gateway must be removed to access the A T O board. The reservoir , or JIB, rests behind the right door of the fryer .
LOV ™ Generation II T echnical Reference 4 Problem Probable Causes Corrective Action Frypots won’t top off. A. Probe temperature lower than setpoint. B. Oil is too cold. C. Bad Connection. D. A TO board power loss. E. Failed transformer/harness. F .
LOV ™ Generation II T echnical Reference 5 (1) Responding to the Blue LED fi lter prompt with “yes” starts a fi lter cycle that lasts about as long as a cook cycle (approx. 4 minutes). Communication between the M3000 computer , the manual interface (MIB board), and the automatic intermittent fi ltration (AIF board) handle the process.
LOV ™ Generation II T echnical Reference 6 Manual — Used to toggle between automatic and manual fi ltration mode. The unit must be in manual mode for the other MIB buttons to operate. Select — Used to scroll through the vats, which are shown numerically in the LED.
LOV ™ Generation II T echnical Reference 7 1L, 1r - 5L, 5r — Numbers correspond to vats: “L” indicates the left side of a split vat. “r” indicates a full vat or the right side of a split vat. A — Auto mode: auto fi ltration enabled. E — Drain or r eturn valve not in desired state: display alternates between E and vat number .
LOV ™ Generation II T echnical Reference 8 Problem Probable Cause Corrective Action Auto fi ltration won’t start. Filter pan out of position. Oil Level is too low . Ensure MIB board is not in manual mode. Ensure MIB cover is not damaged and pressing against buttons.
LOV ™ Generation II T echnical Reference 9 Problem Probable Cause Corrective Action MIB board alternat- ing “E” and “vat number and side.” Network error on the CAN bus communication.
LOV ™ Generation II T echnical Reference 10 T roubleshooting the AIF System (AIF) Problem Probable Cause Fix Wrong vat opens. Actuator is plugged into wrong connector . Locator pin is in wrong position. 1. 2. Ensure the actuator is plugged into the correct connection (J1 for FV return, J3 for DV return; J6 for FV drain, J7 for DV drain).
LOV ™ Generation II T echnical Reference 11 If oil is surrounding the heater , the oil will prevent the heater from ever reaching its setpoint. Once oil is removed during fi ltration, the heater reaches setpoint and cycles a thermostat every four seconds.
LOV ™ Generation II T echnical Reference 12 M3000 Computer Overview The M3000 computer retains the one-button ease of the M2000 and M100B, combining it with the utility of 40-product menu capability . It will operate with electric and gas fryers, both full- and split- vat.
LOV ™ Generation II T echnical Reference 13 Navigation The M3000 uses and buttons to navigate the various menus and submenus. When programming, the left screen shows the menu or submenu item.
LOV ™ Generation II T echnical Reference 14 Basic Operation T urn Fryer ON Press right key for full pot; press key on desired side on a split pot. T urn Fryer OFF Press right key for full pot; press key on desired side on a split pot. Check Frypot T emperature Press T emp key once.
LOV ™ Generation II T echnical Reference 15 Cooking With Multi-Product Display Press a product button. V at with appropriate setpoint displays: MC CHICK. Skip to step 5. If a duty is required for this menu item , duty is displayed when it is time to perform a duty, such as shake.
LOV ™ Generation II T echnical Reference 16 Cooking With Dedicated Display QUAL is displayed when the quality time has elapsed. Qu al Pressing the cook channel button restores the display to FR FRIES and the unit is ready for cooking . FR F Rie s Pressing the cook channel button now will launch a cook cycle and end the quality countdown .
LOV ™ Generation II T echnical Reference 17 Press and quickly release product button for french fries. <<<<<>>>>> 1 Computer will change from Hash Brn to <<<<<>>>>>; an alarm will sound.
LOV ™ Generation II T echnical Reference 18 Press and quickly release product button for hash browns. <<<<<>>>>> 1 Computer display will change from FR Fries to <<<<<>>>>>; an alarm sounds.
LOV ™ Generation II T echnical Reference 19 M3000 Menu Items Location in IO manual The following chart maps the menu options available in the M3000 computer and indicates the location of more information on each menu item within the LOV ™ Fryer Installation and Operation Manual .
LOV ™ Generation II T echnical Reference 20 Loading and Updating Software Procedures Updating the software takes appr oximately 20 minutes. T o update the softwar e, follow these steps: 1. Switch all computers to OFF OFF . Press the TEMP button to check current M3000/MIB/AIF/A T O software version.
LOV ™ Generation II T echnical Reference 21 M3000 T roubleshooting Problem Probable Causes Corrective Action No display on computer . A. Computer not turned on. B. No power to the fryer . C. Power switch turned of f. D. Loose fuse holder . E. Computer has failed.
LOV ™ Generation II T echnical Reference 22 Problem Probable Causes Corrective Action M3000 display shows RECOVERY FAULT RECOVERY FAULT CALL SERVICE. CALL SERVICE. Recovery time exceeded maximum time limit for two or more cycles. Silence the alarm by pressing the 9 button.
LOV ™ Generation II T echnical Reference 23 Problem Probable Causes Corrective Action M3000 display shows low temp low temp alternating with MLT-CYCL with MLT-CYCL . Frypot temperature is between 180°F (82°C) and 315°F (157°C). This display is normal when the fryer is fi rst turned on while in the melt cycle mode.
LOV ™ Generation II T echnical Reference 24 Problem Probable Causes Corrective Action M3000 display shows software for only M3000 or MIB but not all boards. Loose or damaged harness. Check that all harnesses between M3000’s, MIB, AIF and A TO are secure.
LOV ™ Generation II T echnical Reference 25 M3000 Useful Codes T o enter any of the following codes: Press and hold and simultaneously for TEN seconds; three chirps sounds. The computer displays TECH MODE TECH MODE . Enter the codes below to perform this function.
LOV ™ Generation II T echnical Reference 26 Service Required Errors A SERVICE REQUIRED SERVICE REQUIRED error alternating with YES YES displays on the computer . After YES YES is pressed the alarm is silenced. The computer displays an error message from the list below three times with the location of the error .
LOV ™ Generation II T echnical Reference 27 CODE ERROR MESSAGE EXPLANA TION E01 REMOVE DISCARD (Right) A product cook is started on the right side of a split vat or in a full vat that has a different setpoint other than the current vat temperature.
LOV ™ Generation II T echnical Reference 28 T ech Mode T ech mode allows technicians to reset all passwords set in Levels One and T wo and change the time at which the fryer calls for a fi lter pad change.
LOV ™ Generation II T echnical Reference 29 4. Press the 9 (1 yes yes ) button. The computer displays ENTER CODE ENTER CODE . 5. Enter 1234 1234 . The computer displays Language Language on the left and english english on the right. 6. Use the _ and ` buttons to scroll through the language menu.
LOV ™ Generation II T echnical Reference 30 16. Enter the date using the number buttons 0-9. 17. W ith the desired selection displayed, press the 9 (1 yes yes ) button. The computer displays fryer type fryer type on the left and Elec Elec on the right.
LOV ™ Generation II T echnical Reference 31 Filter Error Flow Chart This chart follows the process of clearing a Filter Error Filter Error prompt. The prompt is displayed when any of the following occur: 1. a clogged fi lter pad, 2. a tripped or defective fi lter pump, 3.
LOV ™ Generation II T echnical Reference 32 RTI-equipped Systems Some stores may be equipped with R TI oil storage systems. If so, some of the settings, wiring, and troubleshooting may differ from normal LOV ™ fryer systems. (See next page for bulk oil wiring.
LOV ™ Generation II T echnical Reference 33 TEST I N G BETWEEN PI NS 2 & 8 J6 MI B SHOU L D READ: 24 VAC W HEN RT I TAN K I S F U L L 0V A CW H E NR T I T A N KI S N O TF U L L BLAC K 24V A C I .
LOV ™ Generation II T echnical Reference 34 Oil Disposal and Fill with RTI-equipped Systems Bulk oil systems have large oil storage tanks, typically located in the rear of the restaurant, that are connected to the rear manifold on the fryer .
LOV ™ Generation II T echnical Reference 35 Drain Ball Valves Waste Oil Tank Fryer Filter Pump Built-in Filter B ox Built-in Filter B ox New Oil Pump New Oil Pump Fry Pots New Oil Tank Top-off Jug T.
LOV ™ Generation II T echnical Reference 36 RTI LOV™ T est Quick Reference DISPOSE TO W ASTE, REFILL V A T FROM BULK: 1. Hold down “Filter” button until computer beeps twice. 2. Scroll down to “Dispose” using “Info” button then press “ 9 ” button.
LOV ™ Generation II T echnical Reference 37 FILL V A T FROM BULK: 1. Hold down “ fi lter” button until computer beeps twice. 2. Scroll down to “Fill V at from Bulk” using the Info button. 3. Press “ 9 ”. 4. “Fill V at from Bulk? Y es/No” is displayed.
LOV ™ Generation II T echnical Reference 38 Board and Computer Replacement Readdress All Boards It is necessary to readdress any replaced boards by resetting all power to the entire fryer battery system.
LOV ™ Generation II T echnical Reference 39 Remove this screw that secures the AIF board to the fryer . After removing the screw , the AIF assembly drops down. The bottom tab slides out of the bracket attached to the frypot. MIB Replacement The MIB controller is located inside the left cabinet (see image below).
LOV ™ Generation II T echnical Reference 40 M3000 Computer Replacement The M3000 computer is located on the front of the fryer . Disconnect the fryer from the electrical power supply . The controller bezel is held in place by tabs at the top and bottom.
LOV ™ Generation II T echnical Reference 41 LOV ™ Electric Fryer Wiring Diagrams START OF 6-WIRE DATA & POWER.
LOV ™ Generation II T echnical Reference 42 LOV ™ Gas Fryer START OF 6-WIRE DATA & POWER.
LOV ™ Generation II T echnical Reference 43 Data Network Flow Chart Right M3000 Middle M3000 Left M3000 MIB Left AIF Middle AIF Right AIF ATO J10 J9 J5 J7 J6 J7 J6 J7 J6 J1 J2 J4 J5 J4 J5 J4 120 Ω Pins 2 & 3 120 Ω Pins 2 & 3 NOTE: Pins 2 & 3 can be tested on any plug throughout the system and should read 120 Ω .
LOV ™ Generation II T echnical Reference 44 Connector From/T o Harness # Pin # Function V oltage Wire Color J8 RTI Add Solenoid 8074671 1 24V AC Ret 24V AC Black 2 3 A TO Pump Relay 4 24V AC Ret 24V.
LOV ™ Generation II T echnical Reference 45 MIB (Manual Interface Board) Pin Positions and Harnesses Connector From/T o Harness # Pin # Function V oltage Wire Color J1 M3000 J7 8074546 1 Ground Blac.
LOV ™ Generation II T echnical Reference 46 MIB (Manual Interface Board) Display Diagnostics DISPLA Y LED EXPLANA TION Drain V at # (The vat number is followed by an “L” to indicate left side of a split vat or an “r” to indicate the right side of a split vat or a full vat.
LOV ™ Generation II T echnical Reference 47 Connector From/T o Harness PN Pin # Function V oltage Wire Color J1 FV Return N/A 1 Ret + (Open) 24VDC Black 2 Ret – (Closed) 24VDC Red 3 Ret Position P.
LOV ™ Generation II T echnical Reference 48 Connector From/T o Harness PN Pin # Function V oltage Wire Color J2 Interface Board to Computer 807-4199 SMT Computer to Interface Board Harness 1 12V AC .
Frymaster L.L.C. 8700 Line A venue, Shreveport, LA 71 106 Service Center (800) 551-8633 or (318) 865-171 1 Printed in the United States of America English © 2009 February 23, 2010.
Ein wichtiger Punkt beim Kauf des Geräts Frymaster M3000 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Frymaster M3000 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Frymaster M3000 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Frymaster M3000 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Frymaster M3000 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Frymaster M3000 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Frymaster M3000 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Frymaster M3000. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Frymaster M3000 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.