Benutzeranleitung / Produktwartung FRS18PYW2 des Produzenten Frigidaire
Zur Seite of 25
Model(indoor/outdoor): FRS09PYW1/FRS09PYC1 FRS12PYW1/FRS12PYC1 FRS184YW2/FRS184YC2 FRS18PYW2/FRS18PYC2 FRS224YW2/FRS224YC2 FRS22PYW2/FRS22PYC2 a c . e r i a d i g i r f .
Safety precautions 04 Safety precautions DANGER! Avoid Serious Injury This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician.
T o prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. 1.
operation. It may cause electric removed, do not touch the metal parts of the unit. It may cause an injury . shock or injury. and electric shock. It may cause failure of appliance 11.Do not open the unit during 13.Do not disassemble or modify unit. 14.
Precautions for Installation Installation at the following sites may cause problems. If you must inevitably install 2. Sites with a high concentration of salinity , such as coastal areas.
Outdoor Unit 1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. There must not be the possibility of increased noise and vibration at the site.
.
Attention 1. This illustration is for explanation purposes only . 4 3 1 Indoor unit Outdoor unit 5 6 Air filter More A B C 2. Copper tubes must be insulated independently More than 6.
1.58'' 7.91'' 5.31'' 1.58'' A B (A:33.31" B:10.83") =18000 Btu's (A:36.97" B:11.73") Indoor unit outline Installation plate the ceiling from the wall from the wall Refrigerant pipe 6" or more fr om 6 " or more hole (right) Ø 2.
Indoor unit installation Attention Fixing the Installation Plate Drilling the Hole 1. Install the installation plate horizontally over the structural parts on the wall using the spaces indicated on the plate, as shown 2. In the case of tiled, concrete or diameter holes.
Connective pipe and drainage installation Drainage 1. Run the drain hose sloping downward. Do not install the drain 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack.
Attention Piping and wrapping 1. Bundle the tubing , connecting cable, and drain hose with tape 2. Because the condensed water from rear of the indoor unit is gathered in ponding box and is anything else in the box. 1. Connect the indoor unit first, then the outdoor unit.
1. Install the outdoor part of the unit on a rigid surface to avoid excess noise and vibration. 2. Direct the air vent toward an area without obstacles.
Settlement of outdoor unit Anchor the outdoor unit tightly and horizontally on a concrete or rigid Air inlet Air inlet Air outlet $ % mount with a bolt and nut 0.
Flaring work Main cause for refrigerant leakage is due to defect in the flaring work. Carry out correct flaring work using the following procedure: 1. Cut the pipes and the cable. A) Use the piping kit accessory or pipes purchased locally . B) Measure the distance between the indoor and the outdoor unit.
4. Flaring work. die in the dimension shown in the table below . OUTER Connection Adjustment 1. Align the pipes to be connected. OUTER TIGHTENING Caution: Excessive twisting may br eak the nut, depending on the installation conditions.
Operating Voltage (Min/Max) RLA LRA FLA HP Output Watts Volts FLA HP Output Watts 9K 115-1-60 ǂ 103/127 16.03 26 0.17 0.04 30 115V-AC 0.38 0.03 20 22 12K 115-1-60 ǂ 103/127 17.53 26 0.17 0.04 30 115V-AC 0.38 0.03 20 23 18K 208/230-1-60 ǂ 187/253 11.
1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw .
1..
1. Never fail to have an individual power circuit specifically for the air conditioner . As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover . liable to come loose from vibrations to which the unit is subjected during the course of transportation.
Air purging with vacuum pump 1. Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit.
Air purging 24 V acuum pump Charge hose Manifold valve -76cm/Hg Charge hose Handle Lo Handle Hi Outdoor unit Indoor unit When using the vacuum pump F or method of u s ing a manifold valve, refer to it s operation manual.
Electrical safety P erform the electric safe ty check after completing installation: Gas leak check Soap water method Apply a soap water or a liquid neutral detergent on the indoor unit connection or outdoor unit connections by a soft brush to check for leakage of the connecting points of th e piping.
T est running P erform test operation after completing gas leak check at the flare nut connections and electrical safety check. 1. Connect the power , press the ON/OFF button on the remote controller to turn the unit on. cannot be controlled by the remote controller to run in cooling mode, manual operation can be taken.
1. Contact a specialist to install the device. 2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms. 3. Before operating the air conditioner , ensure that the air filter is installed correctly .
Ein wichtiger Punkt beim Kauf des Geräts Frigidaire FRS18PYW2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Frigidaire FRS18PYW2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Frigidaire FRS18PYW2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Frigidaire FRS18PYW2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Frigidaire FRS18PYW2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Frigidaire FRS18PYW2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Frigidaire FRS18PYW2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Frigidaire FRS18PYW2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Frigidaire FRS18PYW2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.