Benutzeranleitung / Produktwartung DH300MY5 des Produzenten Frigidaire
Zur Seite of 34
Dehumidifier SER VICE MANU AL MODELS: DH300EY5/DH305Y5/DH300MY5 LD40Y5/DH400MY5 DH404EY5/DH400EY5/LD40EY5 DH504ELY5/LD50ELY5 LD65ELY5 http://biz.LGser vice.com CA UTION - BEFORE SER VICING THE UNIT , READ THE SAFETY PRECA UTIONS IN THIS MANU AL. - ONL Y FOR A UTHORIZED SER VICE.
—2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ...........................................................................................................................3 1.2 FEATURES AND DIMENSIONS ......................................................
—3— 1. PREF A CE This Service Manual provides various service information, including the mechanical and electrical parts. This dehumidifier was manufactured and assembled under the strict quality control procedures. The refrigerant is charged at the factory.
—4— 1.4 SPECIFICA TIONS 1.3 MODEL NAMES MODEL NAME CAPACITY (Pints/24hrs) 30 40 50 65 MECHANICAL TYPE ELECTRONIC TYPE CONTROL PANEL DH305Y5, DH300MY5 DH400MY5 , LD40Y5 - - DH300EY5 DH404Y5 DH504ELY5 LD65ELY5 DH400EY5,LD40EY5 LD50ELY5 *NOTE:Specifications are subject to minor change without notice for further improvement.
— 5 — 1 2 3 4 5 6 7 8 9 Off Max High Low Fan Speed Humidity Control Auto Shut-Off Constantly On. FA N SPEED TIMER High Low 4hr. On/Off 2hr. On/Off HUMIDITY CONTROL BUCKET FULL POWER AUT O REST ART HUMIDITY SETTING Humidity Control • When you first use the dehumidifier , tur n the humidity control to 5 or 6.
— 6 — 1.6.1 HO W DOES THE DEHUMIDIFIER WORK? Moist, humid air is drawn over a cold refrigerated dehumidifying coil. Moisture in the air condenses on this coil and drains into a bucket (or through the bucket into a hose and drain).
—7— 1.6.5 HUMIDITY CONTROLLER 1.6.5.1 Mechanical Type The humidity control can be set anywhere between Off and Max for normal operation. If you need more dehumidification, turn the Humidity Control toward Max. If you need less dehumidification, turn the Humidity Control toward Off.
—8— 2. CIRCUIT DIA GRAM • MODEL : DH305Y5, DH300MY5 Q'TY PER SET 1 1 1 1 1 1 1 1 1 1 1 RE- MARKS S S S S S S S S S S S 1 2 3 4 5 6 7 8 9 10 11 DESCRIPTION POWER CORD ASSEMBLY SWITCH, ROCKER.
—9— • MODEL : DH300EY5 S: SERVICE PARTS A: ALTERNATE PARTS N: NOT SERVICE PARTS Q'TY PER SET 1 1 1 1 1 1 1 1 1 RE- MARKS S S S S S S S S S 1 2 3 4 5 6 7 8 9 DESCRIPTION POWER CORD ASSEMBLY .
—10— • MODEL : DH400MY5/LD40Y5 Q'TY PER SET 1 1 1 1 1 1 1 1 1 1 1 RE- MARKS S S S S S S S S S S S 1 2 3 4 5 6 7 8 9 10 11 DESCRIPTION POWER CORD ASSEMBLY SWITCH, ROCKER MOTOR ASSEMBLY CAPAC.
—11— • MODEL : DH404EY5/DH400EY5/LD40EY5 Q'TY PER SET 1 1 1 1 1 1 1 1 1 RE- MARKS S S S S S S S S S 1 2 3 4 5 6 7 8 9 DESCRIPTION POWER CORD ASSEMBLY MOTOR ASSEMBLY CAPACITOR COMPRESSOR,SET.
—12— • MODEL : DH504ELY5/LD50ELY5/LD65ELY5 Q'TY PER SET 1 1 1 1 1 1 1 1 1 1 RE- MARKS S S S S S S S S S S 1 2 3 4 5 6 7 8 9 10 DESCRIPTION POWER CORD ASSEMBLY MOTOR ASSEMBLY CAPACITOR COMPRESSOR (ROTARY), SET OLP.
3.1 MECHANICAL P ARTS 3.1.1 BUCKET AND AIR FIL TER 1. Turn the Humidity Control off(Mechanical type) or press the power button off. (Electronic type) 2. Disconnect the power supply. 3. Remove the bucket. (See Figure 9) 4. Pull out the air filter. (See Figure 10) 3.
3.2 CONTR OL P ARTS 3.2.1 PO WER CORD ASSEMBL Y 1. After opening the control box, remove the screw that holds the ground wire. (See Figure 15) 2. Disconnect the remaining leads of the power cord from the PWB(PCB) ASSEMBLY, MAIN, then remove it from the control box.
— 15 — 3.2.6 COIL ASSEMBL Y , SOLENOID (DH504ELY5, LD50ELY5, LD65ELY5) 1. Disconnect the housing of the COIL ASSEMBLY, SOLENOID from the PCB(PWB) ASSEMBLY, MAIN. 2. Remove the screw that fastens the COIL ASSEMBLY, SOLENOID. (See Figure 19) 3. Pull it out upwards.
3.2.8 F AN AND MO T OR 1. Turn the nut left and full out the Fan by hands carefully. 2. Remove 2 screws that fasten Heat Exchange. 3. Lift the H/E and open the H/E around 45 degree clockwise carefully. (See Figure 22) 4. Unfasten 3 screws that secure the Motor and earth wire.
—17— 3.3 REFRIGERA TING CYCLE 3.3.1 CONDENSER, EV APORA T OR AND CAPILLAR Y TUBE 1. Remove the insulation on the Heater/Evaporator (H/E) assembly 2.
—18— 1. When replacing a refrigeration component, be sure to discharge the refrigerant system by using a refrigerant recovery system. 2. After discharging the unit completely, remove the desired component, and unbraze the pinch-off tubes. 3. Solder service valves into the pinch-off tube ports, leaving the valves open.
— 19 — Equipment needed: Vacuum pump, charging cylinder, manifold gauge, brazing equipment. pinch-off tool capable of making a vapor-proof seal, leak detector, tubing cutter, hand tools to remove components, service valve.
CONDITION 1. Dehumidifier does not start. (Both compressor and fan motor do not operate.) 2. Motor runs but compressor does not run. 3. Does not defrost control. 4. Insufficient dehumidification CAUSE No power Poor plug contact at outlet. Bucket is full.
—21— CONDITION 5. Noisy operating 6. Water drips 7. Compressor cycles on overload protector. (OLP) CAUSE Fan Loose foreign material inside the housing. Tube hits frame. Fan blade hits frame Internal compressor noise. Loose set screws Worn bearings of Motor Assembly The bucket is not installed properly.
—22— 5. EXPLODED VIEWS • MODEL: DH305Y5/DH300MY5 354210 554030 131400 349600 149980 165010 346811 359012 264110 148391 144410 752140 152302 436500 249950 266010 130410 235512 149410 435300 33087.
— 23 — • MODEL: DH300EY5 354210 554030 131400 349600 149980 165010 346811 359012 264110 148391 144410 752140 436500 249950 266010 130410 435300 330870 135312 W0CZZ-2 268711-2 35211A 552111 56750.
—24— • MODEL: DH400MY5/LD40Y5 W0CZZ-2 165010 268711-2 264110 249950 352113 552111 550140 567502 554160 354210 554030 131400 349600 149980 346811 359012 148391 144410 752140 152302 436500 266010 .
—25— • MODEL: DH404EY5/DH400EY5/LD40EY5 W0CZZ-2 165010 268711-2 264110 249950 352113 552111 550140 567502 554160 354210 554030 135312 131400 349600 149980 346811 359012 148391 144410 752140 1523.
— 26 — • MODEL: DH504ELY5/LD50ELY5 W0CZZ-2 165010 268711-2 264110 249950 35211A 352113 552204 567502 554160 550140 354210 554030 135312 131400 349600 149980 346811 359012 148391 144410 752140 15.
— 27 — • MODEL: LD65ELY5 W0CZZ-2 165010 268711-2 264110 249950 35211A 552204 352113 567502 554160 550140 354210 135312 554030 131400 349600 149980 346811 359012 148391 144410 752140 152302 43650.
—28— 6. REPLA CEMENT P A R TS LIST • MODEL: DH305Y5/DH300MY5 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A10285C 330870 DRAIN PAN ASSEMBLY 3087A1.
—23— • MODEL: DH300EY5 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A10254F 330870 DRAIN PAN ASSEMBLY 3087A10019C 148391 TANK ASSEMBLY,BUCKET 4839.
—30— • MODEL: DH400MY5/LD40Y5 130410 BASE ASSEMBLY 3041A10042B 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A10285E / 3531A20285B "B:LG/E:Goldstar" 330870 DRAIN PAN ASSE.
— 31 — • MODEL: DH404E Y 5/DH400EY5/LD40EY5 130410 BASE ASSEMBLY 3041A10042B 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A10254A/E "A:Goldstar/E:LG" 330870 DRAIN PAN AS.
—32— • MODEL: DH504ELY5/LD50ELY5 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A10254A/E "A:Goldstar/E:LG" 330870 DRAIN PAN ASSEMBLY 3087.
—33— • MODEL: LD65ELY5 130410 BASE ASSEMBLY 3041A10042A 131400 CABINET 3090A10042A 135312 FRONT GRILLE,ASSEMBLY 3531A10254E 330870 DRAIN PAN ASSEMBLY 3087A10019C 148391 TANK ASSEMBLY,BUCKET 4839.
P/No : 3828A31001 January, 2005 Printed in China.
Ein wichtiger Punkt beim Kauf des Geräts Frigidaire DH300MY5 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Frigidaire DH300MY5 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Frigidaire DH300MY5 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Frigidaire DH300MY5 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Frigidaire DH300MY5 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Frigidaire DH300MY5 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Frigidaire DH300MY5 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Frigidaire DH300MY5. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Frigidaire DH300MY5 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.