For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed.
www .fmiproducts.com 1 15386-01D 2 SAFETY W ARNING: Do not install a re pl ace inse rt in thi s box unl es s the manufacturer's instructions with the insert specically state this replace ha s be en tested for use with this insert.
www .fmiproducts.com 1 15386-01D 3 SPECIFICA TIONS 0" TO BOTTOM OUTSIDE AIR (LEFT SIDE ONL Y) TOP SP ACERS 3/4" AIR SP ACE BACK AND SIDES HEARTH EXTENSION 66" X 20" 12" EACH S.
www .fmiproducts.com 1 15386-01D 4 FIREPLACE INST ALLA TION SELECTING LOCA TION T o det erm ine safes t and mos t efc ien t loca ti on for replace, you must take into consideratio n the following guidelines: 1. Locat ion must allow for prope r clearanc es (see Figures 1 and 2).
www .fmiproducts.com 1 15386-01D 5 HEARTH EXTENSION A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of replace opening is required to protect combustible oor construction in front of replace.
www .fmiproducts.com 1 15386-01D 6 FIREPLACE INST ALLA TION Continued Figure 4 - Mantel Clearances to Combustible Material Electrical Bushing Electrical Cover Plate Rocker Switch Figure 6 - Fan Switch.
www .fmiproducts.com 1 15386-01D 7 Figure 8 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN 42" Fireplace 37 1 / 2 " 12-8DM 12-8HT Pipe Section 10 5 / 8 " 18-8DM 18-8HT Pipe Sectio.
www .fmiproducts.com 1 15386-01D 8 VENTING INST ALLA TION Continued Figure 9 - T ypical Offset Installation Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max.
www .fmiproducts.com 1 15386-01D 9 Figure 1 1 - Elbow Offset B A Screws Figure 10 - Ceiling Support Pipe 12S-8DM OFFSET RISE CHIMNEY LENGTH A B 48" 36" 24" 18" 12" 4 3 / 8 &qu.
www .fmiproducts.com 1 15386-01D 10 VENTING INST ALLA TION Continued Pitch Slope Opening "A" Max. Used Flashing Model No. Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45.0° 20 3 / 8 " V12F-8DM 4. Remove shingles around opening mea - sured.
www .fmiproducts.com 1 15386-01D 11 Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 15 - Flashing Installation Figure 16 - St.
www .fmiproducts.com 1 15386-01D 12 10' 2' Min. 10' 3' Min. 2' Min. 3' Min. Level of Flue Gas Outlet Figure 19 - 10 Foot Rule 10 FOOT RULE All ue gas outlet chimney te.
www .fmiproducts.com 1 15386-01D 13 OPTIONAL GAS LINE INST ALLA TION Figure 21 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Gas line hook up should be done by your supplier or a qualied service person.
www .fmiproducts.com 1 15386-01D 14 OPTIONAL GAS LINE INST ALLA TION Continued W ARNING: If the replace has been used for wood burn- ing, rebox and chimney must be cl eaned of soot, creosote an d ashes be a qualied chimney cleaner . Creosote will ignite if heavily heated.
www .fmiproducts.com 1 15386-01D 15 Figure 24 - Damper Handle Location OPERA TION AND MAINTENANCE Continued DAMPER HANDLE OPERA TION Damper handle, which opens and closes damper blade, is located inside rebox at cen ter to ward s bac k w all (s ee Fi gure 24 ).
www .fmiproducts.com 1 15386-01D 16 P ARTS WOOD BURNING FIREPLACE MODEL B42LI-M 1 1 27 30 23 22 24 10 14 25 4 17 3 2 1 5 20 28 12 7 15 9 16 13 8 26 6 29 19 18 21.
www .fmiproducts.com 1 15386-01D 17 P ARTS WOOD BURNING FIREPLACE MODEL B42LI-M This list contains replaceable parts used in your replace. When ordering parts, see Replace- ment Parts on page 18 of this manual.
www .fmiproducts.com 1 15386-01D 18 ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM ACCESSORIES DOUBLE W ALL PIPE 12-8DM 12-8HT 18-8DM 18-8-HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM.
www .fmiproducts.com 1 15386-01D 19 FIRESTOP SP ACER FS-8DM F AN KIT - BK3 BLOWER KIT - BK ROUND TOP TERMINA TIONS RT -8DM, RTL-8DM ROUND TOP TERMINA TIONS WITH SLIP SECTION RTT -8DM, RTTL-8DM OUTSIDE.
1 15386-01 Rev . D 06/10 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www .fmipr oducts.com.
Ein wichtiger Punkt beim Kauf des Geräts FMI B42LI-M (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie FMI B42LI-M noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für FMI B42LI-M - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von FMI B42LI-M reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über FMI B42LI-M erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon FMI B42LI-M besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von FMI B42LI-M verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit FMI B42LI-M. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei FMI B42LI-M gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.