Please visit www .firstechonline.com for additional installation resources MODEL : RF-2W900FM-5PT F irstech, LLC. 21911 68th Ave S. Kent, W A 98032 Phone.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com T able of Contents CM6000 Copyright 2009 F irstech, LLC. P age 2 Introduction 4 Kit Contents 4 Installation .
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 3.
Introduction CM6000 CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 4 Thank you for purchasing this Firstech system for your vehicle. The following installation manual is intended for experienced and authorized Firstech technicians.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 5 Installation Basics CM6000 If you are new to installing Firstech Series Remote Starts and / or Alarms, we highly recommended that you thoroughly review this manual to installing your rst unit.
R emote Programming Routine CM6000 CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 6 IMPOR T ANT : Any and all remotes must be coded to the control module prior to performing any and all opera- tions.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 7 Placement and Use of Components CM6000 IMPOR T ANT : The placement and use of components are critical to the performance of this system.
Placement and Use of Components CM6000 Firstech Shock Sensor For best results mount the shock sensor by zip tying it to the vehicles main ignition harness. There is a small dial on the sensor that ranges from Off to 10. The higher the number on the dial the greater sensitivity of impact.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 9 Jumper 3 (Parking Light to T runk Output) Determines the output type (not polarity) of the green/white wire on connector one (CN1).
Copyright 2009 F irstech, LLC. P age 10 CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Alternator Sensing Alternator sensing is an alternative method the remote start can utilize to determine if the engine is running.
Copyright 2009 F irstech, LLC. P age 11 CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Installation Requirements 1. The vehicle’ s door triggers must be connected to the control module. Prior to making nal connections, test the factory door triggers to ensure that they are functioning properly .
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 12 The new CM6 Series the Blade connector has a locking tab. Non-locking tab blade harnesses will work but you MUST T AKE CARE T O NOT PLUG THE HARNESS IN UPSIDE DOWN .
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 13 There are two wires coming off of the relay; yellow-black and yellow .
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 14 Connector 2 (CN2), 2-Pin: Optional Battery Back-up Pin 1 Red - Constant 12 V positive (+) input and (+) charging output.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 15 Pin 8 V iolet/Black - T runk negative (-) input. This is an optional input that will monitor when the vehicle’ s trunk has been opened.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 16 Pin 17 White [POC 8] - Horn honk 250mA negative (-) output. This is an optional output that will pulse the factory horn.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 17 Connector 6 (CN6), 4-Pin (RS 232 Data Port) This connector is used for updating control modules via www .rstechonline.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 18 Connector 10 (CN10), 6-Pin to 6-Pin (Pr e-wired Antenna Cable) Connect your antenna cable to this port. Y ou can only use 6 to 6 pin antenna cables.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 19 Connector 14 (CN14), 4-Pin (Optional Sensor Input) This connector provides optional sensor inputs. Most commonly used with proximity and tilt sensors.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 20 Option Group 2 Feature Default Setting - I Optional Setting - II Opt.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 21 Option Group 3 Continued Feature Default Setting - I Optional Settin.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 22 Special Option Group 1 Feature Setting V alue (Seconds) 1 Diesel T i.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 23 1-04 Double Pulse Unlock - If enabled, this option will cause the system to double pulse the unlock output. This option is used on a majority of T oyota vehicles.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 24 2-01 T ach Sensing Method – This option will adjust the method at which tach is read by the module. At de fault this option will minimize overcrank during remote start.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 25 2-09 T emperat ure of Hot Starting – W orks in conjun ction wit h Options 2-05 and 2- 06. See th e option t able for available temperatures.
Copyright 2009 F irstech, LLC. P age 26 CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com 3-07 Siren Duration (Upon Alarm T rigger) - This option changes the time that the siren sounds during alarm trigger . The available options are 30, 60, and 120 seconds.
Copyright 2009 F irstech, LLC. P age 27 CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com 4-01 Aux 1 Output - This option determines the duration of the auxiliary 1 output. Setting IV allows the out put duration to be set for a specic length of time.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 28 4-08 Extended Accessory After Ignition Shutoff – This option keeps the Accessory wire powered up after the ignition is shut off.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 29 Special Option Groups 1 & 2 CM6000 IMPOR T ANT : The OP500 is required to change settings in Special Option Groups 1 and 2.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 30 At the end of menu 4, if diesel mode or auxiliary setting functions were enabled – or if any of the auxiliary out - puts were set to “Program”, the duration of these settings can now be adjusted.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 31 How T o Program Options With 1 W ay Remotes With 2 W ay Remotes (W a.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 32 T roubleshooting CM6000 Remote Start Error Codes If the remote start fails to start the vehicle, the parking lights will ash three times immediately .
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 33 I am trying to program the control module with the OP500 Option Programmer and it ashes “ER 01” when I plug it in to the antenna cable.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 34 The vehicle will lock and unlock, but will not remote start or ash the parking lights. A: The system is in valet mode.
CM6000 Install Guide Alarm and Starter System www .firstechonline.com | www .compustar .com Copyright 2009 F irstech, LLC. P age 35 Firstech technical support is reserved for authorized dealers only . Monday - Friday: 888-820-3690 (8:00 am – 5:00 pm Pacic Coast T ime) Email: support@compustar .
Ein wichtiger Punkt beim Kauf des Geräts Firstech, LLC. RF-2W900FM-5PT (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Firstech, LLC. RF-2W900FM-5PT noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Firstech, LLC. RF-2W900FM-5PT - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Firstech, LLC. RF-2W900FM-5PT reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Firstech, LLC. RF-2W900FM-5PT erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Firstech, LLC. RF-2W900FM-5PT besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Firstech, LLC. RF-2W900FM-5PT verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Firstech, LLC. RF-2W900FM-5PT. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Firstech, LLC. RF-2W900FM-5PT gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.