Simply connecting the world Patch Release Note Patch 86222-22 For Rapier Switches and AR800 Series Modular Switching Routers Intr oduction This patch release n ote lists the issues addr essed and enhancements made in patch 8622 2-2 2 for Softwar e Rel ease 2.
2 Patch Release Note Patch 86222-22 f or Softwar e Release 2.2.2 C613-103 19-00 REV U Features in 86222-22 The fir ewall was blocking outbou nd ICMP packets when the associated private interface had a ‘deny all’ rule. Th e passing of ICMP packets should be controlled by the ICMP_FOR W A RDING and PING parameters.
Patch 86222 -22 For Rapier Switches and AR800 S eries Modul ar Switching Route rs 3 Patch 86222-22 for Softwar e Release 2.2 .2 C613-103 19-00 REV U The sour ce IP addres s in DVMRP prune an d graft message s was incorrect. This issue has been r esolved.
4 Patch Release Note Patch 86222-22 f or Softwar e Release 2.2.2 C613-103 19-00 REV U Whe n the sw itch was u nder heav y learn ing l oad , some M AC add r ess w ere lost.
Patch 86222 -22 For Rapier Switches and AR800 S eries Modul ar Switching Route rs 5 Patch 86222-22 for Softwar e Release 2.2 .2 C613-103 19-00 REV U Sometimes the retransmission o f an F TP packet was not permi tted through the Firewall. This issue has been reso lved.
6 Patch Release Note Patch 86222-22 f or Softwar e Release 2.2.2 C613-103 19-00 REV U Features in 86222-20 Patch file deta ils for Patch 86 222-20 are listed in T able 3: Patch 86222-20 includes all issues r esolved and enhancements r eleased in previous patches f or Software Re lease 2.
Patch 86222 -22 For Rapier Switches and AR800 S eries Modul ar Switching Route rs 7 Patch 86222-22 for Softwar e Release 2.2 .2 C613-103 19-00 REV U The IP Filter SIZ E parameter was no t being applied correctly . Thi s issue has been r esolved. The SET IP FIL TER command would n ot update the SIZE parameter correctly .
8 Patch Release Note Patch 86222-22 f or Softwar e Release 2.2.2 C613-103 19-00 REV U When the only feature licence in the featur e licence file was disabled, the licence file stored on FLASH memory did not chan ge. This was due to a previous enhancement in PCR 02184 which pr evented existing files being deleted befor e a new version was stored .
Patch 86222 -22 For Rapier Switches and AR800 S eries Modul ar Switching Route rs 9 Patch 86222-22 for Softwar e Release 2.2 .2 C613-103 19-00 REV U The virtual MAC addr ess was used as the sour ce MAC for all packets forwar ded on a n interface associated w ith a V irtual Router (VR).
10 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U VRRP used the wr ong source IP addr ess in ICMP redir ects. RFC 2338 states that the sour ce IP addre s s of ICMP r edirects should be the IP a ddress tha t the end host used when making its next hop routing decision.
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 11 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U The built in Self T est Code for all Rapiers, except G6, h as been improved to enhance the detection of faults in switch chip external packet memory .
12 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U Features in 86222-18 Patch file deta ils for Patch 86 222-18 are listed in T able 5: Ther e is no patch r elease 862 22-17 because this patch was w ithdrawn .
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 13 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U Port mirroring on th e Rapier 48 and 48 i was not operating corr ectly because Destination Lookup Failur e (DLF ) frames wer e sent fr om th e mirro r port.
14 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U A switch sometime s restarted if it was configured with stati c DHCP en tries and wa s handl ing a large numb er of D HCP cli ents. Th is issue ha s been res o l v e d .
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 15 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U Features in 86222-14 Patch file details are listed in T able 8. Patch 86222-14 i ncludes all issues r esolved and enhancements r eleased in previous patches f or Software Re lease 2.
16 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U Firewall IP access lists we re not working correctly . If an IP rang e was specified without spaces betw een the IP address and the separating '-' the range would be ignored.
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 17 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U If route filters existed and a RESET IP command was executed, some static and interfac e routes wer e in correctly r emoved if the f ilters matched.
18 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U The firewall wa s incorrectly forwarding multi cast pa ckets origi nating from a private addr ess in cases where a matching route was defined. Th is issue has been r esolved.
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 19 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U The first periodic after day trigger boundary (i.e. midni ght) did not occur . A range check error occurr ed due to an incorrect comparison.
20 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U Features in 86222-10 Patch file deta ils for Patch 86 222-10 are listed in T able 12. T able 12: Pat ch file deta ils for Patch 862 22-10. Patch 86222-10 i ncludes all issues r esolved and enhancements r eleased in previous patches f or Software Re lease 2.
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 21 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U The default setting for th e switch port parameter INFIL TERING is now OFF , as specified in IEEE802.1Q.
22 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U When IGMP snooping was enabled, if a member left a g roup on a port, it could not re- j oin the group on that port. Th is issue has been resolved. Substantial changes have been made to PIM in more r ecent code re l eases.
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 23 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U MD5 Authentica tion now wo rks correctly with RIP packets.
24 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U In some cond itions it was po ssible fo r ISAKMP packets to be lo st and no t retransmitted. Incoming ISAKMP mess ages are now validated before stopping retransmission of the previous message.
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 25 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U The CREA TE CONFIG command did n o t include all r equired L3FIL T ER parameters in the generated script file.
26 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U Features in 86222-05 Patch file deta ils for Patch 86 222-05 are listed in T able 17. Patch 86222-05 i ncludes all issues r esolved and enhancements r eleased in previous patches f or Software Re lease 2.
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 27 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U When a VLAN was cr eated and then destr oyed on the G6 or G6F , the VT ABLE was corrupted. This has been fixed.
28 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U In a dual policy configura tion, the fi rewall would lock up under load. The firewall would also mistakenly report SYN attacks. These is sues have been res o l v e d .
Patch 86222 -22 For Rapier Switch es and AR8 00 Series Modul ar Switching Routers 29 Patch 86222-22 for Software Release 2.2 .2 C613-103 19-00 REV U Features in 86222-01 Patch file deta ils for Patch 86 222-01 are listed in T able 19. Patch 86222-01 i ncludes the following enhanceme nt for Softwar e Release 2.
30 Patch Release Note Patch 86222-22 f or Software Release 2.2.2 C613-103 19-00 REV U A vailability Patches can be downloaded from the Softwar e Updates area of the Allied T elesyn web sit e at w ww . allied teles yn.co .nz/s uppo rt/up date s/pat ches.
Ein wichtiger Punkt beim Kauf des Geräts Allied Telesis R800 Series (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Allied Telesis R800 Series noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Allied Telesis R800 Series - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Allied Telesis R800 Series reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Allied Telesis R800 Series erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Allied Telesis R800 Series besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Allied Telesis R800 Series verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Allied Telesis R800 Series. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Allied Telesis R800 Series gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.