Benutzeranleitung / Produktwartung MKP 2000 des Produzenten Extron electronics
Zur Seite of 35
User ’ s Manual Extron Electronics, USA 1230 South Lewis Street Anaheim, CA 92805 USA 714.491.1500 Fax 714.491.1517 Extron Electronics, Eur ope Beeldschermweg 6C 3821 AH Amersfoort The Netherlands +31.33.453.4040 Fax +31.33.453.4050 Extron Electronics, Asia 135 Joo Seng Road, #04-01 PM Industrial Building Singapore 368363 +65.
Precautions This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product's enclosure that may present a risk of electric shock.
MKP 2000 Remote Control Panel • Quick Start Guide QS-1 Install and set up the MKP 2000 as follows: Step 1 T urn all of the equipment off and disconnect it from the power sour ce. Step 2 Install the cables to and from the control panel in a wall, podium, or desk.
MKP 2000 Remote Control Panel • Quick Start Guide Quick Start Guide — MKP 2000, cont’d i MKP 2000 Remote Control Panel• Table of Contents Chapter 1 • Introduction .......................................................... 1-1 About the MKP 2000 Remote Control Panel .
ii MKP 2000 Remote Control Panel • Table of Contents T able of Contents, cont’d MKP 2000 Remote Control Panel 1 Chapter One Introduction About the MKP 2000 Remote Control Panel 68-971-01 A 01 05 All trademarks mentioned in this manual are the pr operties of their respective owners.
MKP 2000 Remote Control Panel • Introduction MKP 2000 Remote Control Panel • Introduction Introduction This manual provides installation and operation instructions for the Extron MKP 2000. About the MKP 2000 Remote Control Panel The MKP 2000 is a network-r eady remote contr ol panel that can control any Extr on matrix switcher.
MKP 2000 Remote Control Panel • Introduction MKP 2000 Remote Control Panel • Introduction Introduction 2 Chapter T wo Installation MKP Installation Overview UL Requirements for Wall Box Installati.
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation 2-3 UL Requirements for W all Box Installation The following Underwriters Laboratories (UL) requirements pertain to the installation of the MKP 2000 into a wall or furniture (figure 2-1).
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d Preparing the site, installing the mud ring or wall box Choose a location that allows cable runs without interference. Allow enough depth for both the wall box and the cables.
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d 2-6 7a . If you are using a mud ring , follow the directions, if any , that came with the mud ring to attach the clips that fasten the ring to the wall or furniture (figur e 2-3).
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d 3 . Mount the MKP’s faceplate to the mud ring or wall box with machine screws (figure 2-5). M K P 200 0 4 5 6 1 23 7 8 9 B A C K 0 CANC EL INPUT OUTPUT TAKE R Figure 2-5 — Mounting the MKP to the wall box 4 .
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d Control connections The MKP has two RS-232 ports; a Host port ( 1 ) and a Switcher port ( 2 ); and an Ethernet (LAN) port ( 3 ).
MKP 2000 Remote Control Panel • Installation MKP 2000 Remote Control Panel • Installation Installation, cont’d TP cable termination It is vital that your Ethernet cables be the correct cables, and that they be pr operly terminated with the correct pinout.
MKP 2000 Remote Control Panel • Installation Installation, cont’d MKP 2000 Remote Control Panel 3 Chapter Thr ee Local Operation Front Panel Controls and Indications Front Panel Operations Rear Panel Resets 2-14 Power supply wiring Figure 2-12 shows how to wir e the connector .
MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation 3-2 Front Panel Controls and Indications MKP 2000 456 123 789 BACK 0 CANCEL INPUT OU.
MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d When an input or output outside the available range for this MKP or the connected matrix switcher is selected, the LED display shows N - A .
MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d 1 9 21 6 8 .2 5 42 5 3 .. 2 5 52 5 5 .0 0 00 0 0 .. 0 0 00 0 0 .0 0 00 0 0 .. 0 0 00 0 0 . . . . . . . . . . . . . 0 0 00 0 0 .
MKP 2000 Remote Control Panel • Local Operation MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d 3-8 Control panel security lockout (executive mode) The front panel security lockout limits the MKP’s front panel operation to input and output selection only (IP addr ess modification is locked).
MKP 2000 Remote Control Panel • Local Operation Local Operation, cont’d MKP 2000 Remote Control Panel 4 Chapter Four SIS Operation RS-232 Links Ethernet Link Host-to-MKP Instructions MKP-Initiated.
MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation RS-232 Links The MKP’s rear panel 3-pole, 3.
MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d This message means that the switcher requires an administrator or user level passwor d before it will perform the commands entered via this link.
MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d Symbol definitions for MKP SIS commands = CR/LF (carriage return/line feed) (0x0.
MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d Command/response table for MKP SIS commands (continued) Command ASCII Command Re.
MKP 2000 Remote Control Panel • SIS Operation MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d Command/response table for MKP SIS commands (continued) Command ASCII Command Re.
MKP 2000 Remote Control Panel • SIS Operation SIS Operation, cont’d MKP 2000 Remote Control Panel 4-14 5 Chapter Five HTML Operation Download the Startup Page System Status Page System Settings Pa.
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation 5-3 5-2 5 . Press the keyboard Enter key . The MKP checks to see if it is password protected. If the MKP is not password pr otected, proceed to step 7 .
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-5 5-4 System Status Page The System Status page (figure 5-2) provides an overall view of the status of the MKP , including various IP addresses, the status of the Host and Switch RS-232 ports, and the voltage.
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-7 5-6 IP Settings section Unit Name field The Unit Name field contains the locally-assigned name of the MKP . This name field can be changed to any valid name, up to 24 alphanumeric characters.
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-9 5-8 Authorized inputs and authorized outputs Y ou can use the Authorized Inputs and Authorized Outputs drop boxes to narr ow the number of inputs and outputs that are controllable fr om the MKP .
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-11 5-10 Passwords Page Access the Passwords page (figure 5-5) by clicking the Configuration tab and then the Passwords link on the left side of the System Settings page.
MKP 2000 Remote Control Panel • HTML Operation MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d 5-13 5-12 7 . Click the Browse button. An open file window appears (figure 5-7). Figure 5-7 — Firmware upgrade open file window 8 .
MKP 2000 Remote Control Panel • HTML Operation HTML Operation, cont’d MKP 2000 Remote Control Panel 5-14 Special Characters The HTML language reserves certain characters for specific functions. The MKP will not accept these characters as part of its name, passwords, or locally cr eated file names.
MKP 2000 Remote Control Panel • Reference Data MKP 2000 Remote Control Panel • Reference Data Reference Data A-3 A-2 Specifications Control/remote — keypad Extron remote key pad control .. (2) 3.5 mm, 3-pole captive screw connectors General External power supply .
MKP 2000 Remote Control Panel • Reference Data MKP 2000 Remote Control Panel • Reference Data Reference Data , cont’d A-5 A-4 Mounting and Cabling Specifications Electrical box cutout Any standard box that meets the local electrical codes can be used, but boxes from dif ferent manufacturers can have different size openings.
MKP 2000 Remote Control Panel • Reference Data Reference Data , cont’d Extron Comm-Link cable W ire specifications for Extron Comm-Link cable (figure A-2) are as follows: A (red) = 18 A WG B (viol.
Ein wichtiger Punkt beim Kauf des Geräts Extron electronics MKP 2000 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Extron electronics MKP 2000 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Extron electronics MKP 2000 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Extron electronics MKP 2000 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Extron electronics MKP 2000 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Extron electronics MKP 2000 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Extron electronics MKP 2000 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Extron electronics MKP 2000. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Extron electronics MKP 2000 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.