Benutzeranleitung / Produktwartung XTP PI 400 des Produzenten Extron electronic
Zur Seite of 16
User Guide XTP PI 400 XTP Power Injector Four Port XTP Power Injector 68-2291-01 Rev . D 11 13.
Safety Instructions Safety Instructions Safety Instructions • English WARNING: This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated danger ous voltage within the product’ s enclosure that may pr esent a risk of electric shock.
FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part15 of the FCC rules. The ClassA limits provide r easonable protection against harmful interference when the equipment is operated in a commer cial environment.
Conventions Used in this Guide Notifications The following notifications are used in this guide: W ARNING: A warning indicates a situation that has the potential to result in death or severe injury . A TTENTION: Attention indicates a situation that may damage or destroy the product or associated equipment.
Contents Introduction ................................................... 1 About the XTP PI 400 ......................................... 1 Features ............................................................. 2 Installation and Operation ..........
XTP PI 400 Power Injector • Contents vi.
XTP PI 400 Power Injector • Introduction 1 Intr oduction This guide contains information about the Extron XTP PI 400 Power Injector with instructions for experienced installers on how to install, configure, and operate the equipment. In this guide, the term “XTP PI 400” is used to refer to the XTP PI 400 Power Injector .
XTP PI 400 Power Injector • Introduction 2 100-240V x.xA 50/60 Hz 1 XTP PWR XTP PWR 2 XTP PWR XTP PWR 3 XTP PWR XTP PWR 4 XTP PWR XTP PWR XTP PI 400 POWER 12V Rx G Tx RS-232 IR R L Rx Tx - +- + 1 2 .
XTP PI 400 Power Injector • Installation and Operation 3 Installation and Operation This section contains installation procedur es and operation features.
XTP PI 400 Power Injector • Installation and Operation 4 W ARNING: Risk of electrical shock. T o reduce the risk of fire or electric shock, do not expose this apparatus to rain, moisture, dripping, splashing, or objects filled with liquids. Refer all servicing to qualified service personnel.
XTP PI 400 Power Injector • Installation and Operation 5 Rear Panel Connectors 100-240V 1.6 A 50/60 Hz 1 XTP PWR XTP PWR 2 XTP PWR XTP PWR 3 XTP PWR XTP PWR 4 XTP PWR XTP PWR XTP PI 400 bb bb cc cc Figure 3. Rear Panel Features A TTENTION: Do not connect these devices to a computer data or telecommunications network.
XTP PI 400 Power Injector • Installation and Operation 6 T wisted Pair Cable Recommendations Use the following pin configurations for twisted pair cables. TIA/EIA-T568B Pin Wir e Color 1 White-orange 2 Orange 3 White-green 4 Blue 5 White-blue 6 Green 7 White-brown 8 Brown Figure 6.
XTP PI 400 Power Injector • Installation and Operation 7 LED Indicators 1 XTP POWER OUT XTP PI 400 XTP POWER INJECTOR 2 3 4 ab Figure 7. Front Panel Featur es a Front panel power LED indicator — Lights to indicate the XTP PI 400 is r eceiving power .
XTP PI 400 Power Injector • Reference Information 8 Refer ence Information Mounting The XTP PI 400 is 1U high and one half rack wide. A TTENTION: • The XTP PI 400 is not suitable for use in air handling spaces or in wall cavities.
XTP PI 400 Power Injector • Reference Information 9 Rack Mounting Mount the XTP PI 400 to an optional Extron rack shelf. T o mount the unit on a rack shelf, follow the instructions provided with the shelf accessories. Use 2 mounting holes on opposite corners.
Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only) Extron USA - W est Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 F AX +1.919.850.1001 F AX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.4050 F AX Extron Asia +65.
Ein wichtiger Punkt beim Kauf des Geräts Extron electronic XTP PI 400 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Extron electronic XTP PI 400 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Extron electronic XTP PI 400 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Extron electronic XTP PI 400 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Extron electronic XTP PI 400 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Extron electronic XTP PI 400 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Extron electronic XTP PI 400 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Extron electronic XTP PI 400. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Extron electronic XTP PI 400 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.