User Guide XTRA ™ Series Audio Products Half-Rack Audio P ower Amplifiers 68-1351-01 Rev . D 07 12.
This symbol is intended to alert the user of important operating and mainte- nance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’ s enclosure that may present a risk of electric shock.
FCC Class B Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pr ovide reasonable pr otection against harmful interference in a r esidential installation.
.
Contents Introduction ................................................. 1 About this Manual ........................................... 1 T erms Used in this Manual ........................... 1 Features ...............................................
.
Intr oduction About this Manual This manual contains information about the Extron XTRA Series of power ampliers. • XP A 1002 two-channel stereo audio power amplifier • XP A 2001-70V mono audio.
Convection cooled — The XTRA Series of amplifiers are convection cooled without the need for fans, ensuring quiet, reliable operation. Ultra low inrush current - no need for power sequencing — Allows many XTRA Series amplifiers to be powered on simultaneously without overloading power cir cuits.
Installation This section discusses how to install the XTRA Series of audio power amplifiers. T opics that are covered, include: • Application Examples • Mounting the XP A 1002 and XP A 2001 WARNING: Failur e to follow these instructions may result in serious injury .
50/60 Hz 100-240V 0.3A L 1 R L 2 R L 3 R L 4 R L 1 R L 2 R L 3 R L 4 R L 1 R L 2 R L 3 R L 4 R L 3 R L 4 R I N P U T S O U T P U T S C O N T R O L I N P U T S O U T P U T S RESET ACT LINK RS-232 1 2 3.
3. Mechanical loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
Rack Mounting V entilation Recommendations Excessive heat can decrease the optimal lifetime of the power amplier . An over temp indicator LED on the front panel of the amplier lights r ed whenever the recommended operating temperature has been exceeded.
NOTE: If needed, Extron r ecommends using a UL-rated crimp tool to terminate the spade connectors. One recommended choice is the Molex crimp tool (Molex part #64001-0100). The kit provides a convenient means to r eplace the XP A ’ s IEC power cord with conduit, where r equired by local codes.
100-240V 1.3A 50-60Hz Re mo ve scr ew s (both sides) to re lease IEC connec to r plat e. Re mo ve nu t Blue Wire Br ow n Wire L N Figure 6. Removing the IEC Connector 4. Remove the gr ound wire nut fr om the grounding stud on the bottom of the enclosure, as shown above.
Operation This section discusses how to operate the XTRA Series of audio power amplifiers. T opics that are covered, include: • Front Panel Featur es and Operation • Rear Panel Features and Opera.
c Limiter/Protect indicator LEDs (channels 1 and 2) — These LEDs (r epresenting output channels 1 and 2) light red under thr ee circumstances: 12 LIMITER/PRO TECT • When the output wiring is shorted together • When audio clipping occurs, the corresponding channel’ s LED blinks once per clip occurrence.
Rear Panel Featur es and Operation 100-240V 0.5A, 50-60Hz XP A 2001-70V LIMITER/PROTECT SIGNAL 0 2 4 6 8 10 12 18 14 26 ∞ ATTENU AT ION HPF 70 V OUTPUT REMOTE INPUTS CLASS 2 WIRING G G C V L (SUMMED.
d Attenuation (channels 1 and 2) — Use a small screwdriver to adjust the audio input level for the corresponding channel. The analog potentiometers contr ol the level from = (full attenuation) to 0 dB. NOTES: • On the XP A 2001, the single control adjusts the levels of both channels simultaneously prior to summing them together .
â Balanced or unbalanced stereo or mono audio input connector (XP A 2001) — Wire the 3.5 mm 5-pin captive screw connector for balanced or unbalanced input.
• Pin 5 connected to ground (pin 4) places the amplifier in standby mode. Standby mode turns off all output, although the amplier is still receiving power . Use the included 2-pin, 3.5 mm captive screw connector to r emotely ground pin 5. The power indicator LED lights amber when the amplier is in standby mode.
T o wire the stereo audio output connector: Step 1: Strip and insert the speaker wires into the connector and tighten the captive screws. Be sur e to observe the correct polarity . Do not tin the wires! Step 2: Insert the wired connector into the amplifier output and secur e the locking screws on either side.
T o wire the mono audio output connector: Step 1: Strip and insert the speaker wires into the connector and tighten the captive screws. Be sur e to observe the correct polarity . Do not tin the wires! Step 2: Insert the wired connector into the amplifier output and secur e the locking screws on either side.
Remote V olume Control Options for remote contr ol of the XP A ampliers include the Extron VCM 100 and VC 50 volume controllers. Thir d party 10k potentiometer volume controllers can also be connected to this port. As shown in the following illustration, pin V (1) on the XP A is a 10 VDC reference voltage.
Controlling Multiple Amplifiers with One V olume Controller Several XP A 1002 and XP A 2001 units can be daisy-chained so that one volume controller can simultaneously regulate the volume of all the amplifiers. NOTES: • As additional amplifiers ar e added to the daisy chain, the sensitivity of the volume potentiometer will change.
Bridged Mono Output The power output of the XP A 1002 can be effectively doubled by bridging the output. Bridging allows power to be output in mono at 200 watts at 8 ohms. NOTES: • The bridging instructions that follow apply only to the XP A 1002 model.
T r oubleshooting The front and r ear panels have LED warning indicators, as described in the following diagnostic information. Amplifier Fails to Exit Standby Mode Promptly The input channel (channels 1 and 2) Signal LED lights green per indicated input channel when an input signal is detected.
Limiter/Protect LED W arning Indicators The output channel (channels 1 and 2) Limiter/Protect LED lights r ed per indicated output channel as shown in the following diagnostic information. LED State Problem Description Problem Solution Blinks Audio clipping is occurring at the rate of one blink per clip.
Refer ences This section discusses the part numbers and accessories for the XTRA Series of half-rack audio power amplifiers. Part Numbers and Accessories Included parts Included parts Replacement par.
Extron Headquarters +1.800.633.9876 (Inside USA/Canada Only) Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX Extron Europe +800.3987.6673 (Inside Europe Only) +31.33.453.4040 +31.33.453.4050 FAX Extron Asia +800.
Ein wichtiger Punkt beim Kauf des Geräts Extron electronic XPA1002 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Extron electronic XPA1002 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Extron electronic XPA1002 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Extron electronic XPA1002 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Extron electronic XPA1002 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Extron electronic XPA1002 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Extron electronic XPA1002 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Extron electronic XPA1002. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Extron electronic XPA1002 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.