Benutzeranleitung / Produktwartung IPL T CR48 des Produzenten Extron electronic
Zur Seite of 66
User’ s Manual IP Link ® T ools 68-738-05 Rev . B 11 08 IPL T CR48.
Pr ecautions This symbol is intended to alert the user of important opera ting and mainten ance (se rvicing ) instru ctions i n the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
安全须知 • 中文 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 这个符号警告用户该设备机壳内有暴 露的危险电压,有触电危险。 .
This page has been intentionally left blank..
IPL T CR48 • Quick Start Guide QS-1 T o install and set up an IPL T CR48 interface, follow these steps: Step 1 T urn all of the equipment off and disconnect it fr om the power source. Step 2 Mount the IPL T CR48 interface near a scr een, screen lift, lighting system, or projector lift, as illustrated below .
IPL T CR48 • Quick Start Guide Quick Start Guide — IPL T CR48, cont’d QS-2 LAN POWER 12V 0.5A INPUT 2 1 3 4 5 6 7 8 1 2 3 4 Extron IPL T CR48 Ethernet Control Interface Projector Lighting System Screen Control Projector Lift Control Step 4 Attach the input and relay connections to the IPL T unit.
i IPL T CR48 • T able of Contents T able of Contents Chapter One • Introduction .................................................... 1-2 About this Manual .................................................................... 1-2 About the IPL T CR48 Interface .
ii IPL T CR48 • T able of Contents T able of Contents, cont’d 68-738-05 B 11 08 All trademarks mentioned in this manual are the properties of their respective owners. Sending an e-mail alert through T elnet ............................4-7 Upgrading the rmare .
IPL T CR48 1 Chapter One Intr oduction About this Manual About the IPL T CR48 Interface Features.
IPL T CR48 • Introduction Intr oduction About this Manual This manual contains information about the Extron IPL T CR48 (Extron part #60-544-05) Ethernet-based r elay control interface, including how to install, congure, and operate it.
IPL T CR48 • Introduction 1-3 protection pr ovide appropriate security . Contact closure input ports — Can be used to sense when a switch or relay has been activated. Easily connected — Provides RJ-45 auto-sense 10/100 Mbs Ethernet LAN connection.
IPL T CR48 • Introduction Introduction, cont’d 1-4.
IPL T CR48 2 Chapter T wo Installation and Operation Installation Overview Mounting the IPL T CR48 Rear Panel Features and Cabling Operation.
IPL T CR48 • Installation and Operation Installation and Operation Installation Overview T o install and set up an IPL T CR48 r elay control interface, follow these steps: 1. T urn all of the equipment off. Make sure that the input devices (motion detectors, alarms, photo eyes, etc.
IPL T CR48 • Installation and Operation 2-3 Figure 2-1 — Mounting the interface on the V ersaT ools shelf N Only products in the IP Link ® or V ersaT ools ™ lines can be mounted to a V ersaT ools shelf. Any 1U rack- mountable Extron pr oduct can be mounted on the standard shelf (Extron part #60-190-01).
IPL T CR48 • Installation and Operation Installation and Operation, cont’d 2-4 Furniture or projector mounting In addition to using the IPL T CR48 unit on a rack, it can also be furniture or pr ojector mounted.
IPL T CR48 • Installation and Operation 2-5 Rear Panel Features and Cabling All connections, including power , input and output, and control, are on the back panel of the IPL T CR48 interface. Figure 2-4 — IPL T CR48 interface back panel Power a Power connection — Plug the external 12 V power supply into this connector .
IPL T CR48 • Installation and Operation Installation and Operation, cont’d 2-6 W The two power cord wires must be kept separate while the power supply is plugged in. Remove power before continuing. T o verify the polarity before connection, plug in the power supply with no load and check the output with a voltmeter .
IPL T CR48 • Installation and Operation 2-7 Figure 2-7— Example application using input and relay ports Operation Connect power cords and turn on the r elay controlled output devices (projector lifts, scr een lifts, lights, etc.), input (trigger) devices (motion detectors, alarms, photo eyes, etc.
IPL T CR48 • Installation and Operation Installation and Operation, cont’d 2-8 Front panel indicators The front panel of the IPL T CR48 has several indicator LEDs which show the current status of communications to and fr om the unit. A reset button is also available from the fr ont panel, in a small recess next to the Power LED ( a ).
IPL T CR48 • Installation and Operation 2-9 C The listed reset modes (with the exception of Mode 2) will close all open IP and T elnet connections and close all sockets.
IPL T CR48 • Installation and Operation Installation and Operation, cont’d 2-10 Nothing happens if the momentary press does not occur within one second.
IPL T CR48 3 Chapter Thr ee Connection and Configuration Connecting the Hardware Configuring the Hardware.
IPL T CR48 • Connection and Conguration Connection and Configuration 3-2 Connecting the Hardwar e T o connect the IPL T CR48 unit, connect the input and output devices to the unit using gure 3-1 as a guide.
IPL T CR48 • Connection and Conguration 3-3 1 kohm pull-up resistor and must be wir ed with a ground. This allows the input to be tied to devices such as motion detectors, alarms, photo eyes, etc. Users dene what this input triggers via control softwar e.
IPL T CR48 • Connection and Conguration Connection and Configuration, cont’d 3-4 1. Connect one end of the relay cable to a 8-pole captive screw connector , wired appropriately , and plug it into the rear panel r elay port connector of the interface unit.
IPL T CR48 • Connection and Conguration 3-5 Configuring the IPL T CR48 using the ARP command Y ou can make use of the ARP (Address Resolution Pr otocol) command to set up an IP addr ess for your IPL T CR48 interface. The ARP command tells your computer to associate the IPL T CR48 unit’s MAC address with the assigned IP address.
IPL T CR48 • Connection and Conguration Connection and Configuration, cont’d Figure 3-3 — Executing the ARP command 5. Execute a Ping command by typing your new IP addr ess at the command prompt.
IPL T CR48 • Connection and Conguration Configuring the IPL T CR48 using direct PC connection This type of connection is used initially to connect to and congure the IPL T CR48 unit.
IPL T CR48 • Connection and Conguration Connection and Configuration, cont’d 9. After conguring your IPL T CR48, repeat steps 3 and 4 and change your TCP/IP settings back to their original conguration. Firmware upgrades Firmware upgrades become available as impr ovements are made to the versatility and functionality of the IPL T CR48.
IPL T CR48 4 Chapter Four Communication and Contr ol Ports Overview Communication with the Interface Programmer’ s Guide for the T elnet and Web Browser Device Control T roubleshooting.
IPL T CR48 • Communication and Control Communication and Contr ol Ports Overview Contact closure input ports The contact closure inputs on the IPL T CR48 are able to detect a closed circuit between any of the inputs and gr ound.
IPL T CR48 • Communication and Control Communication with the Interface Web server The on-board W eb server is displayed as a set of default W eb pages which can be accessed via a W eb browser . These pages are the primary means of communication with, and control thr ough, the IPL T CR48 interface.
IPL T CR48 • Communication and Control Communication and Control, cont’d Figure 4-3 — W eb server system status screen Establishing or changing system or port settings The System Settings screen is used to initially congur e or change conguration of the IPL T CR48 interface.
IPL T CR48 • Communication and Control 2. Make changes to the IP settings or Date/T ime settings, as necessary . 3. Click the Submit button to enter the changes, or click the Cancel button to revert to the pr evious settings.
IPL T CR48 • Communication and Control Communication and Control, cont’d Figure 4-6 — W eb server passwords scr een 4. Once passwords have been set, you will be r equired to enter a password (gur e 4-2) whenever you log on to the unit. N T o clear a password, enter a single space, repeat the entry , and click the Submit button.
IPL T CR48 • Communication and Control Figure 4-7 — Email alerts scr een N Due to the 7 character limit for full file names, it’ s advised that you use numeric titles (e.g., 1.eml, 24.eml). Numeric titles reduce the characters of the file name, and assist in keeping the alert files organized.
IPL T CR48 • Communication and Control Communication and Control, cont’d Upgrading the firmware Firmware upgrades become available as impr ovements are made to the versatility and functionality of the IPL T CR48 interface. These upgrades are available for download fr om the Internet.
IPL T CR48 • Communication and Control T o add or update les: 1. Select the File Management tab and the File Management screen (gur e 4-9) is displayed. Figure 4-9 — W eb server File Management screen 2. Click the Browse button to locate the le you want to upload.
IPL T CR48 • Communication and Control Communication and Control, cont’d Programmer’ s Guide for the T elnet and Web Browser Using the command/response table The following are either T elnet (port 23) or W eb browser (port 80) commands.
IPL T CR48 • Communication and Control N Upper and lower case text can be used interchangeably except where noted. Symbol denitions are shown below .
IPL T CR48 • Communication and Control Communication and Control X1! = Unit version number X1@ = Name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and/or a minus sign/hyphen (-). No blank or space characters are permitted as part of a name.
IPL T CR48 • Communication and Control X3( = Event data to write X4# = Input state: 0 = off; 1 = on X4$ = Number of bytes to read X4% = E-mail event number: Range = 1-64 (Max) X4^ = E-mail recipient addr ess: Maximum number of characters for a full e-mail address is 31 characters.
IPL T CR48 • Communication and Control Communication and Control, cont’d Password information The “ ] Password:” pr ompt requir es a password (administrator level or user level) followed by a carriage return. The pr ompt is repeated if the corr ect password is not enter ed.
IPL T CR48 • Communication and Control 4-15 Command ASCII (T elnet) URL Encoded (Web) Response Relay functions Pulse relay 1*3* X6# O X! %2A3%2A X6# O Cpn X! • Rly3 ] T oggle relay X! *2O X! %2A2O.
IPL T CR48 • Communication and Control Communication and Control, cont’d 4-16 Command ASCII (T elnet) URL Encoded (Web) Response Query factory rmware version 3Q 3Q X1! (plus web ver .-desc-UL date/time) ] Query updated rmware version 4Q 4Q X1! (plus web ver .
IPL T CR48 • Communication and Control 4-17 Command ASCII (T elnet) URL Encoded (Web) Response Read Unit name E CN WCN| X1@] Set time / date 24 E X1# CT } W X1# CT| Ipt • X1# Read time / date E CT.
IPL T CR48 • Communication and Control Communication and Control, cont’d 4-18 Command ASCII (T elnet) URL Encoded (Web) Response V iew DHCP mode E DH } WDH| X%] Set IP addr ess 24 E X1$ CI } W X1$.
IPL T CR48 • Communication and Control 4-19 Command ASCII (T elnet) URL Encoded (Web) Response Read administrator password 24 E CA } WCA| X3#] Set user password 24 E X3# CU } W X3# CU| Ipu • X3#] .
IPL T CR48 • Communication and Control Communication and Control, cont’d 4-20 Command ASCII (T elnet) URL Encoded (Web) Response File Commands Stream files via port 80 Load le to use ash me.
IPL T CR48 • Communication and Control 4-21 Command ASCII (T elnet) URL Encoded (Web) Response Reset W eb port map 24 E 80MH } W80MH| Pmh00080 ] Disable W eb port map 24 E 0MH } W0MH| Pmh00000 ] Rea.
IPL T CR48 • Communication and Control Communication and Control, cont’d 4-22 Command ASCII (T elnet) URL Encoded (Web) Response Read mail server IP , domain name E CM } W X1$ %2C X1% CM| X1$ , X1.
IPL T CR48 • Communication and Control 4-23 Command ASCII (T elnet) URL Encoded (Web) Response Stop Events 24 27 E 0AE } W0AE| Est ] Read number of events running E AE } W AE| Enm# ] Reset (ZAP)/Era.
IPL T CR48 • Communication and Control Communication and Control, cont’d Device Control Control of devices may be accomplished in any of several ways once the IPL T interface has been connected and congured. These include W eb pages, T elnet, and direct port access.
IPL T CR48 • Communication and Control 4. If passwords wer e set up for the connected system, you will be prompted to log in as Administrator or User . Otherwise the system will respond with a <cr/lf>. Figure 4-12— Connecting to the IP addr ess 5.
IPL T CR48 • Communication and Control Communication and Control, cont’d Data connections 1 . Check the cabling connections and make adjustments as needed. The Link LEDs on the IPL T control interface and the computer should be solid green if a network connection is detected.
IPL T CR48 A Appendix A Specifications, Part Numbers, and Accessories Specifications Part Numbers and Accessories.
IPL T CR48 • Specications, Part umbers, and Accessories Specifications, Part Numbers, Accessories A-2 Specifications Ethernet control interface Connectors ..................................... 1 RJ-45 female connector Data rate .............
IPL T CR48 • Specications, Part umbers, and Accessories A-3 T emperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing Mounting Rack mount .
IPL T CR48 • Specications, Part umbers, and Accessories Specifications, Part Numbers, Accessories, cont’d A-4 Part Numbers and Accessories Included parts Included parts Replacement part number IPL T CR48 60-544-05 12 VDC, 1A external power supply (U.
IPL T CR48 B Appendix B Glossary Glossary.
IPL T CR48 • Glossary Glossary B-2 Glossary 10/100Base-T is Ethernet which uses Unshielded T wisted Pair (UTP - Cat 5, etc.) cable, wher e the amount of data transmitted between two points in a given amount of time is equal to either 10 Mbps or 100 Mbps.
IPL T CR48 • Glossary B-3 Global Configurator (GC) is a windows program that, based on user input, creates a GlobalV iewer (GV). GC requests system information such as which devices you have and your current list of IP addresses. W ith this information, GC creates a GlobalV iewer for your specic devices.
IPL T CR48 • Glossary Glossary , cont’d B-4 Ping is a utility that tests network connections. It is used to determine if the host has an operating connection and is able to exchange information with another host.
Extron’ s W arranty Extron Electr onics warrants this product against defects in materials and workmanship for a period of three years fr om the date of purchase.
© 2008 Extron Electronics. All rights reserved. Ex tron US A - We st Headquar te rs + 80 0.6 33 .9 87 6 I nside US A / Ca nada On ly +1 .7 1 4.4 91 .1 50 0 +1 .7 1 4.4 91 .1 51 7 FA X Ex tron US A - East + 800 .6 33 .9 87 6 I nside US A / Ca nada On ly +1 .
Ein wichtiger Punkt beim Kauf des Geräts Extron electronic IPL T CR48 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Extron electronic IPL T CR48 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Extron electronic IPL T CR48 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Extron electronic IPL T CR48 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Extron electronic IPL T CR48 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Extron electronic IPL T CR48 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Extron electronic IPL T CR48 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Extron electronic IPL T CR48. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Extron electronic IPL T CR48 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.