Benutzeranleitung / Produktwartung LBI-31629B des Produzenten Ericsson
Zur Seite of 28
LBI-31629B INCLUDES SER VICE SECTIO N . . . . . . . . . . . . . . LBI-31 677 ericssonz Maintenance Manual M-PD SYSTEM 136-174 MHz PERSON AL TWO-W A Y FM RADIO COMBIN A TION Ericsson Inc. Pri v ate Radio Systems Mountain V iew Roa d L ync hburg, V irginia 24502 1-800- 528-7711 (Ou tside USA, 804-5 28-7711) Printed in U.
Copyright © Apr il 1987, General Electric Compan y SPECIFICA TIONS SYSTEM Frequency Ra nge FCC Id en tification Number 136 MHz to 160 MHz AXA9WNTR-145-A 150 MHz to 174 MHz AXA9WNTR-145-B Frequency Stability 5 PPM Battery Drain (at 7.5 VDC) Standby 65 Milliamperes Recei ver (Rated Audio) 195 Milliamperes T ransmitter 1.
DESCRIPTION Ericsson GE’ s M-PD System Pe rsonal Radio is a high- quality , high-performance, two-way , FM, comm unicat ions uni t consis ting of a transmit/r eceiv e circuit with a frequency syn- thesizer cont rolled by a microprocessor .
• Channel Busy Lo ck Out : Personality information in- cludes the ca pability to preve nt the transmitter from op- erating on a channel where carr ier acti vity is present.
Assemble these part s into one unit according to the fol- lowing procedure and as sho wn in Figure 1 - M-PD Op erat- ing Controls and Accessories. 1. Screw the antenna or the RF te st connector In its receptacle. A clockwise turn will insert the antenna or RF test connector , while a counter clockwise turn will remove them.
2. U se the DTMF keypad or use the Recall T elephone Number key (RCL) to enter the digits of the te le- phone nu mb er . 3. Press the secondar y key and the n press the SEND key . An optional tone (sidetone) m ay be heard as each digit is transmitted.
Q202. The RF power output from Pin 2 of th e TX-Amp module A201 i s conne cted th rough a resist or atte nuator to Pin 1 of the P A module where it is appli e d to t he in pu t of the RF power amplifier stages. The RF power amplifie r stages amplify the input from the TX-Am p module to a typ ical power output le vel of 6 watts at Pin 5.
Synthesizer Circuit The Synt hesizer circu it co ntains P hase-L ock-l oop mod - ule (PLL) A 102, VCTCXO Referenc e Oscillator module A103, TX/RX V oltage Controlled Oscillator modul e (VCO) A106 and a Low Pas s Filter ampl ifie r (LPF). Refer to Fi g- ure 9 - Synthesizer .
CONTR OLLER CIRCUIT This co ntroller circuit consists of contr ol circuits and audio ci rcuits. Physi cally , this circuit consists of three cir- cuit boards as follo ws: • Contr ol Boar d • Signa.
Charger comb inations for charging the battery packs a re av ailable with char ge times of 1 hour , 3 hours and 16 h ours. A combination can be a single unit desk or a vehicular char ger . It can also be a wall mounted multiple charger . Charge Le vel A fully charged battery pack should provide a te rminal voltage greater than 7.
Figure 11 - Disassembly Figure 12 - Disassembly Step 1 Figure 13 - Disassembly Step 2 Figure 14 - Disassembly Step 3 LBI-31629 10.
Figure 15 - Disassembly Step 4 Figure 16 - Disassembly Step 5 Figure 17 - Disassembly Step 6 Figure 18 - Disassembly Step 7 LBI-31 629 11.
INTRINSICALL Y SAFE USA GE Selected personal radios with appropriat e factory installed F4 Options are certi fied as Intrinsically Safe by the Fa ctory Mu tual Research Corp oration for use in Class 1.
1. The battery is continuously overchar ged for lo ng pe ri- ods of time. 2. A regularly performed duty cycle which allo ws the battery to expend only a limited por tion of i ts capa c- ity .
INTERCONNECTION DIA GRAM LBI-31629 14.
RADIO BO ARD A4WE0373 9/40 OUTLINE DIA G RAM COMPONENT SIDE SOLDER SI DE LBI-31 629 15.
SCHEMA TIC DIA GRAM RADIO SCHEMA TIC DIA GRAM WITH TYPI CAL V OL T A GE A4WE0373 9/40 LBI-31629 16.
Contr oller Board A4WE0402 3 OUTLINE DIA G RAM COMPONENT SIDE SOLDER SI DE LBI-31 629 17.
SCHEMA TIC DIA GRAM Contr oller Board A4WE0402 3 LBI-31629 18.
Signalli ng Board A4WE0402 4 OUTLINE DIA G RAM SCHEMA TIC DIA GRAM COMPONENT SIDE SOLDER SI DE M-PD Signaling Board A4WE0402 4 LBI-31 629 19.
LCD Board A4WE0373 7 OUTLINE DIA GRAM COMPONENT SIDE SOLDER SIDE LBI-31629 20.
SCHEMA TIC DIA GRAM LCD 1 Board A4WE0373 7 LBI-31 629 21.
SCHEMA TIC & OUTLINE DIA GRAM Battery Packs LBI-31629 22.
MECHANICAL P ARTS BREAKDO WN M-PD EXPLODED VIEW SYSTEM TYPE A1WL09 006 LBI-31 629 23.
PA R T S L I S T LBI-31629 24.
PA R T S L I S T LBI-31 629 25.
PA R T S L I S T LBI-31629 26.
PA R T S L I S T LBI-31 629 27.
Ein wichtiger Punkt beim Kauf des Geräts Ericsson LBI-31629B (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Ericsson LBI-31629B noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Ericsson LBI-31629B - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Ericsson LBI-31629B reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Ericsson LBI-31629B erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Ericsson LBI-31629B besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Ericsson LBI-31629B verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Ericsson LBI-31629B. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Ericsson LBI-31629B gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.